On the Interaction of Lightning Upward Connecting Positive Leaders With Humans

Upward connecting leaders can be initiated from humans under the influence of lightning downward stepped leaders, thereby causing severe injuries. In order to improve the scarce knowledge about the interaction of upward connecting leaders with humans, a self-consistent model based on the physics of leader discharges is used in this paper. Furthermore, a current-generation-type return-stroke model is applied to calculate the current pulse produced during the neutralization of unsuccessful aborted upward leaders. It is estimated that an upward connecting leader can be initiated even when the victim is located several tens of meters away from the lightning channel. However, the lightning exposure to a direct strike and to an aborted leader is found to be reduced by 50% and 70%, respectively, when an individual standing straight adopts the squat position. In the case of an aborted upward leader, it is estimated that a short-duration pulse of opposite polarity in the kiloampere range would be produced by the neutralization of the leader charge. Rough estimates of the total energy dissipated in the victim's body by the current of an aborted unsuccessful upward leader range between hundred and thousand joules.

[1]  M. Cooper A Fifth Mechanism of Lightning Injury , 2002 .

[2]  Marek Szczerbinski Lightning hazards and risks to humans: some case studies , 2003 .

[3]  Vernon Cooray,et al.  Effect of the space charge layer created by corona at ground level on the inception of upward lightning leaders from tall towers , 2007 .

[4]  Kevin Barraclough,et al.  I and i , 2001, BMJ : British Medical Journal.

[5]  Eduard M. Bazelyan,et al.  Lightning Physics and Lightning Protection , 2000 .

[6]  E. Garbagnati,et al.  Lightning stroke simulation by means of the leader progression model. I. Description of the model and evaluation of exposure of free-standing structures , 1990 .

[7]  Vernon Cooray,et al.  Mathematical modelling of return strokes , 2003 .

[8]  V. Cooray,et al.  A simplified physical model to determine the lightning upward connecting leader inception , 2006, IEEE Transactions on Power Delivery.

[9]  I. Gallimberti,et al.  Theoretical modelling of the development of the positive spark in long gaps , 1994 .

[10]  Vladimir A. Rakov,et al.  Leader properties determined with triggered lightning techniques , 1998 .

[11]  R. Stephenson A and V , 1962, The British journal of ophthalmology.

[12]  F.A.M. Rizk,et al.  Modeling of transmission line exposure to direct lightning strokes , 1990 .

[13]  Vernon Cooray,et al.  Lightning striking distance of complex structures , 2008 .

[14]  Vernon Cooray,et al.  Time dependent evaluation of the lightning upward connecting leader inception , 2006 .

[15]  Mary Ann Cooper,et al.  A fifth mechanism of lightning injury. , 2002, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[16]  I. Gallimberti,et al.  The mechanism of the long spark formation , 1979 .

[17]  David Mackerras Protection from lightning , 1992 .

[18]  V. Rakov,et al.  The lightning striking distance—Revisited , 2007 .

[19]  R.B. Anderson,et al.  Does a fifth mechanism exist to explain lightning injuries? , 2001, IEEE Engineering in Medicine and Biology Magazine.

[20]  Vernon Cooray,et al.  Lightning caused injuries in humans , 2007 .

[21]  V. Cooray,et al.  A self-consistent upward leader propagation model , 2006 .

[22]  A. Bondiou-Clergerie,et al.  A simplified model for the simulation of positive-spark development in long air gaps , 1997 .

[23]  M. Becerra On the Attachment of Lightning Flashes to Grounded Structures , 2008 .