Guidelines for the application of upper-room ultraviolet germicidal irradiation for preventing transmission of airborne contagion -- Part 1: Basic principles

Upper-room ultraviolet germicidal irradiation (UVGI) holds the promise of greatly lowering the concentration of airborne organisms in the lower part of the room and thereby controlling the spread of airborne infection among occupants. The determinants of effectiveness in clearing the lower room air of infectious organisms are the UV irradiance in the upper air, the rate of air mixing between upper and lower zones, and the specific susceptibility of a microbe to UVGI. The germicidal dose is the product of irradiance times duration, and the two components are mutually interchangeable within wide limits. Control of eye exposure to UVGI, to avoid irritation, places practical limits on irradiance levels in occupied rooms, and room air circulation patterns govern irradiation time. Therefore, there must be careful consideration given to the placement of upper-room UVGI fixtures in relation to room geometry and ventilation mode to obtain maximal microbial destroying efficacy. Efficacy can be demonstrated and quantified by calculating the number of additional air changes that would have been required to obtain the same clearance rate of viable microbes that was produced by the installed UVGI alone. For normally ventilated rooms, the air exchange equivalent of well-installed upper-room UVGI is in the range of 10 to 20 air changes per hour for tubercle bacilli.

[1]  H. G. Jenkins,et al.  Applications of Germicidal, Erythemal and Infrared Energy , 1948, Nature.

[2]  A. Oksala [Ultraviolet radiation and the eye]. , 1953, Nordisk medicin.

[3]  J. Phair,et al.  Airborne Contagion and Air Hygiene , 1955 .

[4]  R. Riley,et al.  Room air disinfection by ultraviolet irradiation of upper air. Air mixing and germicidal effectiveness. , 1971, Archives of environmental health.

[5]  R. Riley,et al.  Ultraviolet susceptibility of BCG and virulent tubercle bacilli. , 1976, The American review of respiratory disease.

[6]  E. Nardell,et al.  Clearing the air. The theory and application of ultraviolet air disinfection. , 1989, The American review of respiratory disease.

[7]  E. Nardell,et al.  Airborne infection. Theoretical limits of protection achievable by building ventilation. , 1991, The American review of respiratory disease.

[8]  David Satcher,et al.  Guidelines for preventing the transmission of Mycobacterium tuberculosis in health-care facilities, 1994. Centers for Disease Control and Prevention. , 1994, MMWR. Recommendations and reports : Morbidity and mortality weekly report. Recommendations and reports.

[9]  E. Nardell Interrupting transmission from patients with unsuspected tuberculosis: a unique role for upper-room ultraviolet air disinfection. , 1995, American journal of infection control.

[10]  W W Nazaroff,et al.  Effectiveness of in-room air filtration and dilution ventilation for tuberculosis infection control. , 1996, Journal of the Air & Waste Management Association.

[11]  J. T. Crawford,et al.  A multi-institutional outbreak of highly drug-resistant tuberculosis: epidemiology and clinical outcomes. , 1996, JAMA.

[12]  Melvin W. First,et al.  Characterization of Ultraviolet Upper Room Air Disinfection Devices , 1999 .

[13]  Melvin W. First,et al.  Guidelines for the Application of Upper-Room Ultraviolet Germicidal Irradiation for Preventing Transmission of Airborne Contagion—Part II: Design and Operation Guidance , 1999 .