Aberration-free FTIR spectroscopic imaging of live cells in microfluidic devices.

The label-free, non-destructive chemical analysis offered by FTIR spectroscopic imaging is a very attractive and potentially powerful tool for studies of live biological cells. FTIR imaging of live cells is a challenging task, due to the fact that cells are cultured in an aqueous environment. While the synchrotron facility has proven to be a valuable tool for FTIR microspectroscopic studies of single live cells, we have demonstrated that high quality infrared spectra of single live cells using an ordinary Globar source can also be obtained by adding a pair of lenses to a common transmission liquid cell. The lenses, when placed on the transmission cell window, form pseudo hemispheres which removes the refraction of light and hence improve the imaging and spectral quality of the obtained data. This study demonstrates that infrared spectra of single live cells can be obtained without the focus shifting effect at different wavenumbers, caused by the chromatic aberration. Spectra of the single cells have confirmed that the measured spectral region remains in focus across the whole range, while spectra of the single cells measured without the lenses have shown some erroneous features as a result of the shift of focus. It has also been demonstrated that the addition of lenses can be applied to the imaging of cells in microfabricated devices. We have shown that it was not possible to obtain a focused image of an isolated cell in a droplet of DPBS in oil unless the lenses are applied. The use of the approach described herein allows for well focused images of single cells in DPBS droplets to be obtained.

[1]  H. Bechtel,et al.  Synchrotron infrared measurements of protein phosphorylation in living single PC12 cells during neuronal differentiation. , 2012, Analytical chemistry.

[2]  Luca Quaroni,et al.  Infrared spectromicroscopy of biochemistry in functional single cells. , 2011, The Analyst.

[3]  James P Freyer,et al.  Methods for measuring the infrared spectra of biological cells , 2003 .

[4]  S. Kazarian,et al.  Rapid prototyping of microfluidic devices for integrating with FT-IR spectroscopic imaging. , 2010, Lab on a chip.

[5]  Wayne R. McKinney,et al.  Tracking chemical changes in a live cell: Biomedical applications of SR-FTIR spectromicroscopy , 2002 .

[6]  Rainer Pepperkok,et al.  IR microspectroscopy of live cells , 2005 .

[7]  Wayne R McKinney,et al.  Synchrotron infrared spectromicroscopy as a novel bioanalytical microprobe for individual living cells: cytotoxicity considerations. , 2002, Journal of biomedical optics.

[8]  V. Elings,et al.  Imaging with solid immersion lenses, spatial resolution, and applications , 2000, Proceedings of the IEEE.

[9]  Sergei G. Kazarian,et al.  Micro- and Macro-Attenuated Total Reflection Fourier Transform Infrared Spectroscopic Imaging , 2010 .

[10]  C. Hirschmugl,et al.  Demountable Liquid/Flow Cell for in vivo Infrared Microspectroscopy of Biological Specimens , 2009, Applied spectroscopy.

[11]  Hans A Bechtel,et al.  Synchrotron IR spectromicroscopy: chemistry of living cells. , 2010, Analytical chemistry.

[12]  S. Kazarian,et al.  Correcting the effect of refraction and dispersion of light in FT-IR spectroscopic imaging in transmission through thick infrared windows. , 2013, Analytical chemistry.

[13]  M. Diem,et al.  Monitoring the reversible B to A-like transition of DNA in eukaryotic cells using Fourier transform infrared spectroscopy , 2011, Nucleic acids research.

[14]  Sergei G. Kazarian Enhancing high-throughput technology and microfluidics with FTIR spectroscopic imaging , 2007, Analytical and bioanalytical chemistry.

[15]  Erol C. Harvey,et al.  FTIR spectroscopy of single live cells in aqueous media by synchrotron IR microscopy using microfabricated sample holders , 2010 .

[16]  A. Casson,et al.  Fourier transform infrared (FTIR) spectromicroscopic characterization of stem-like cell populations in human esophageal normal and adenocarcinoma cell lines. , 2010, The Analyst.

[17]  C. Marcott,et al.  Attenuated Total Internal Reflection Infrared Mapping Microspectroscopy Using an Imaging Microscope , 2001 .

[18]  Sergei G. Kazarian,et al.  ATR-FTIR spectroscopic imaging: recent advances and applications to biological systems. , 2013, The Analyst.

[19]  S. Kazarian,et al.  Chemical Imaging of Live Cancer Cells in the Natural Aqueous Environment , 2009, Applied spectroscopy.

[20]  D. Williams,et al.  Fourier Transform Infrared Imaging of Human Hair with a High Spatial Resolution without the Use of a Synchrotron , 2005, Applied spectroscopy.

[21]  S. Kazarian,et al.  Generation of chemical movies: FT-IR spectroscopic imaging of segmented flows. , 2011, Analytical chemistry.

[22]  Haw Yang,et al.  Real-time chemical imaging of bacterial activity in biofilms using open-channel microfluidics and synchrotron FTIR spectromicroscopy. , 2009, Analytical chemistry.

[23]  G. Grenci,et al.  Infrared microspectroscopy of live cells in microfluidic devices (MD-IRMS): toward a powerful label-free cell-based assay. , 2012, Analytical chemistry.

[24]  S. Kazarian,et al.  FT-IR Spectroscopic Imaging of Reactions in Multiphase Flow in Microfluidic Channels , 2012, Analytical chemistry.

[25]  S. Kazarian,et al.  Detection of trace materials with Fourier transform infrared spectroscopy using a multi-channel detector. , 2006, The Analyst.

[26]  R. Haskell,et al.  OPTICS; ATOMS and MOLECULES; SPECTROSCOPY 1613 Resolution limits for infrared microspectroscopy explored with synchrotron radiation , 2001 .

[27]  Max Diem,et al.  Infrared microspectroscopy of live cells in aqueous media. , 2010, The Analyst.

[28]  K. Bambery,et al.  Synchrotron radiation infrared microspectroscopy of arsenic-induced changes to intracellular biomolecules in live leukemia cells , 2010 .

[29]  G. Grenci,et al.  Infrared microspectroscopy of biochemical response of living cells in microfabricated devices , 2010 .