Development of a new generation of high-resolution anatomical models for medical device evaluation: the Virtual Population 3.0

The Virtual Family computational whole-body anatomical human models were originally developed for electromagnetic (EM) exposure evaluations, in particular to study how absorption of radiofrequency radiation from external sources depends on anatomy. However, the models immediately garnered much broader interest and are now applied by over 300 research groups, many from medical applications research fields. In a first step, the Virtual Family was expanded to the Virtual Population to provide considerably broader population coverage with the inclusion of models of both sexes ranging in age from 5 to 84 years old. Although these models have proven to be invaluable for EM dosimetry, it became evident that significantly enhanced models are needed for reliable effectiveness and safety evaluations of diagnostic and therapeutic applications, including medical implants safety. This paper describes the research and development performed to obtain anatomical models that meet the requirements necessary for medical implant safety assessment applications. These include implementation of quality control procedures, re-segmentation at higher resolution, more-consistent tissue assignments, enhanced surface processing and numerous anatomical refinements. Several tools were developed to enhance the functionality of the models, including discretization tools, posing tools to expand the posture space covered, and multiple morphing tools, e.g., to develop pathological models or variations of existing ones. A comprehensive tissue properties database was compiled to complement the library of models. The results are a set of anatomically independent, accurate, and detailed models with smooth, yet feature-rich and topologically conforming surfaces. The models are therefore suited for the creation of unstructured meshes, and the possible applications of the models are extended to a wider range of solvers and physics. The impact of these improvements is shown for the MRI exposure of an adult woman with an orthopedic spinal implant. Future developments include the functionalization of the models for specific physical and physiological modeling tasks.

[1]  Kecheng Liu,et al.  Shape recovery algorithms using level sets in 2-D/3-D medical imagery: a state-of-the-art review , 2002, IEEE Transactions on Information Technology in Biomedicine.

[2]  P B Hoffer,et al.  Computerized three-dimensional segmented human anatomy. , 1994, Medical physics.

[3]  Niels Kuster,et al.  The Virtual Family—development of surface-based anatomical models of two adults and two children for dosimetric simulations , 2010, Physics in medicine and biology.

[4]  S. Koga,et al.  Japanese adult male voxel phantom constructed on the basis of CT images. , 2007, Radiation protection dosimetry.

[5]  M. Clemens,et al.  High-resolution human anatomy models for advanced electromagnetic field computations , 2002 .

[6]  P Boesiger,et al.  4D MR imaging of respiratory organ motion and its variability , 2007, Physics in medicine and biology.

[7]  Supun Samarasekera,et al.  Fuzzy Connectedness and Object Definition: Theory, Algorithms, and Applications in Image Segmentation , 1996, CVGIP Graph. Model. Image Process..

[8]  Heinz-Otto Peitgen,et al.  Efficient Semiautomatic Segmentation of 3D Objects in Medical Images , 2000, MICCAI.

[9]  A. Bozkurt,et al.  VIP-MAN: AN IMAGE-BASED WHOLE-BODY ADULT MALE MODEL CONSTRUCTED FROM COLOR PHOTOGRAPHS OF THE VISIBLE HUMAN PROJECT FOR MULTI-PARTICLE MONTE CARLO CALCULATIONS , 2000, Health physics.

[10]  L. Krishtalik,et al.  Proteins as specific polar media for charge transfer processes , 2012 .

[11]  A. Tarakanova,et al.  Molecular modeling of protein materials: case study of elastin , 2013 .

[12]  Niels Kuster,et al.  Evaluation of the RF heating of a generic deep brain stimulator exposed in 1.5 T magnetic resonance scanners , 2013, Bioelectromagnetics.

[13]  Nina Petoussi-Henss,et al.  The GSF family of voxel phantoms , 2002, Physics in medicine and biology.

[14]  Serge Beucher Sets, partitions and functions interpolations , 1998 .

[15]  P. A. Mason,et al.  Effects of frequency, permittivity, and voxel size on predicted specific absorption rate values in biological tissue during electromagnetic-field exposure , 2000 .

[16]  N. Chavannes,et al.  Mastering Conformal Meshing for Complex CAD-Based C-FDTD Simulations , 2008, IEEE Antennas and Propagation Magazine.

[17]  Hans-Christian Hege,et al.  amira: A Highly Interactive System for Visual Data Analysis , 2005, The Visualization Handbook.

[18]  Niels Kuster,et al.  Patient-specific simulations and measurements of the magneto-hemodynamic effect in human primary vessels. , 2012, Physiological measurement.

[19]  Niels Kuster,et al.  Realistic Skeleton Based Deformation of High-Resolution Anatomical Human Models for Electromagnetic Simulations , 2008 .

[20]  Daniel Lodwick,et al.  Hybrid computational phantoms of the 15-year male and female adolescent: applications to CT organ dosimetry for patients of variable morphometry. , 2008, Medical physics.

[21]  Mark S. Shephard,et al.  Automatic three‐dimensional mesh generation by the finite octree technique , 1984 .

[22]  Chengyu Shi,et al.  A boundary-representation method for designing whole-body radiation dosimetry models: pregnant females at the ends of three gestational periods—RPI-P3, -P6 and -P9 , 2007, Physics in medicine and biology.

[23]  Mark S. Shephard,et al.  Automatic three-dimensional mesh generation by the finite octree technique , 1984 .

[24]  M. P. Billings,et al.  The Computerized Anatomical Man (CAM) model , 1973 .

[25]  P. Dimbylow Development of the female voxel phantom, NAOMI, and its application to calculations of induced current densities and electric fields from applied low frequency magnetic and electric fields , 2005, Physics in medicine and biology.

[26]  S. Koga,et al.  Development of a Japanese Adult Female Voxel Phantom , 2009 .

[27]  Niels Kuster,et al.  Exposure of the Human Body to Professional and Domestic Induction Cooktops Compared to the Basic Restrictions , 2012, Bioelectromagnetics.

[28]  William Gropp,et al.  Efficient Management of Parallelism in Object-Oriented Numerical Software Libraries , 1997, SciTools.

[29]  Jirí Zára,et al.  Spherical blend skinning: a real-time deformation of articulated models , 2005, I3D '05.

[30]  Guenter Schmidt Differential Diagnosis in Ultrasound Imaging: A Teaching Atlas , 2006 .

[31]  W. S. Snyder,et al.  Report of the task group on reference man , 1979, Annals of the ICRP.

[32]  Jonathan Richard Shewchuk,et al.  Tetrahedral mesh generation by Delaunay refinement , 1998, SCG '98.

[33]  D. G. Jones A Realistic Anthropomorphic Phantom for Calculating Organ Doses Arising from External Photon Irradiation , 1997 .

[34]  Gabriel Taubin,et al.  Curve and surface smoothing without shrinkage , 1995, Proceedings of IEEE International Conference on Computer Vision.

[35]  C. Duchon Lanczos Filtering in One and Two Dimensions , 1979 .

[36]  E. Neufeld,et al.  IT’IS Database for Thermal and Electromagnetic Parameters of Biological Tissues , 2012 .

[37]  E. Neufeld High Resolution Hyperthermia Treatment Planning , 2008 .

[38]  Heinz-Otto Peitgen,et al.  IWT-interactive watershed transform: a hierarchical method for efficient interactive and automated segmentation of multidimensional gray-scale images , 2003, SPIE Medical Imaging.

[39]  Greg Hamerly,et al.  Alternatives to the k-means algorithm that find better clusterings , 2002, CIKM '02.

[40]  Choonsik Lee,et al.  Korean adult male voxel model KORMAN segmented from magnetic resonance images. , 2004, Medical physics.

[41]  J. Udupa,et al.  Shape-based interpolation of multidimensional objects. , 1990, IEEE transactions on medical imaging.

[42]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.

[43]  Deanna Hasenauer,et al.  Hybrid computational phantoms of the male and female newborn patient: NURBS-based whole-body models , 2007, Physics in medicine and biology.

[44]  H. Pan,et al.  WHO child growth standards: length/height-for-age, weight-for-age, weight-for-length, weight-for-height and body mass index-for-age , 2006 .

[45]  Niels Kuster,et al.  A novel medical image data-based multi-physics simulation platform for computational life sciences , 2013, Interface Focus.

[46]  Niels Kuster,et al.  Sim4Life: A Medical Image Data Based Multiphysics Simulation Platform for Computational Life Sciences , 2012 .

[47]  P. A. Mason,et al.  Skin heating effects of millimeter-wave irradiation-thermal modeling results , 2000 .

[48]  Benjamin M. W. Tsui,et al.  MCAT to XCAT: The Evolution of 4-D Computerized Phantoms for Imaging Research , 2009, Proceedings of the IEEE.

[49]  Jianping Cheng,et al.  CNMAN: a Chinese adult male voxel phantom constructed from color photographs of a visible anatomical data set. , 2007, Radiation protection dosimetry.

[50]  Tamal K. Dey,et al.  Delaunay Edge Flips in Dense Surface Triangulations , 2007, ArXiv.

[51]  B M Tsui,et al.  Evaluation of cardiac cone-beam single photon emission computed tomography using observer performance experiments and receiver operating characteristic analysis. , 1993, Investigative radiology.