Analysis of linear Phase-Locked Loops in Grid-Connected Power Converters

Fast and accurate synchronization capability of grid-connected converters is becoming more and more important to ensure proper performance during transient events, such as grid faults. The higher requirements during the operation, as Fault-Ride-Through with reactive current injection, cause higher requirements on the operation during severe system conditions. This paper analyzes an addition to Synchronous-Reference-Frame Phase-Locked Loops for power electronic converters, that is linearizing the input signal. This enhances the tracking capabilities during abnormal transient events in the power grid. The improved control is analyzed and its increased performance is validated through simulations and experimental results.

[1]  F. Blaabjerg,et al.  Flexible control of small wind turbines with grid failure detection operating in stand-alone and grid-connected mode , 2004, IEEE Transactions on Power Electronics.

[2]  Frede Blaabjerg,et al.  Overview of Control and Grid Synchronization for Distributed Power Generation Systems , 2006, IEEE Transactions on Industrial Electronics.

[3]  Ioan Serban,et al.  Control Strategy of Three-Phase Battery Energy Storage Systems for Frequency Support in Microgrids and with Uninterrupted Supply of Local Loads , 2014, IEEE Transactions on Power Electronics.

[4]  Frede Blaabjerg,et al.  Control Strategy for Three-Phase Grid-Connected PV Inverters Enabling Current Limitation Under Unbalanced Faults , 2017, IEEE Transactions on Industrial Electronics.

[5]  Thomas M. Jahns,et al.  Linear Phase-Locked Loop , 2018, 2018 IEEE Energy Conversion Congress and Exposition (ECCE).

[6]  Marco Liserre,et al.  Grid Converters for Photovoltaic and Wind Power Systems , 2011 .

[7]  Heng Wu,et al.  Transient Stability Impact of the Phase-Locked Loop on Grid-Connected Voltage Source Converters , 2018, 2018 International Power Electronics Conference (IPEC-Niigata 2018 -ECCE Asia).

[8]  Math Bollen,et al.  Understanding Power Quality Problems: Voltage Sags and Interruptions , 1999 .

[9]  Bo Wen,et al.  Analysis of Phase-Locked Loop Low-Frequency Stability in Three-Phase Grid-Connected Power Converters Considering Impedance Interactions , 2015, IEEE Transactions on Industrial Electronics.

[10]  Frede Blaabjerg,et al.  Unified Impedance Model of Grid-Connected Voltage-Source Converters , 2018, IEEE Transactions on Power Electronics.

[11]  Chong Un,et al.  Performance Analysis of Digital Tanlock Loop , 1982, IEEE Trans. Commun..