Controlling a robotically steered needle in the presence of torsional friction

A flexible needle can be accurately steered by robotically controlling the orientation of the bevel tip as the needle is inserted into tissue. Here, we demonstrate the significant effect of friction between the long, flexible needle shaft and the tissue, which can cause a significant discrepancy between the orientation of the needle tip and the orientation of the base where the needle is controlled. Our experiments show that several common phantom tissues used in needle steering experiments impart substantial frictional forces to the needle shaft, resulting in a lag of over 45° for a 10 cm insertion depth in some phantoms; clinical studies have reported torques large enough to could cause similar errors during needle insertions. Such angle discrepancies will result in poor performance or failure of path planners and image-guided controllers, since the needles used in percutaneous procedures are too small for state-of-the-art imaging to accurately measure the tip angle. To compensate for the angle discrepancy, we develop a model for the rotational dynamics of a needle being continuously inserted into tissue and show how a PD controller is sufficient to compensate for the rotational dynamics.

[1]  Zhe Chen,et al.  Dosimetric effects of needle divergence in prostate seed implant using 125I and 103Pd radioactive seeds. , 2000, Medical physics.

[2]  Allison M. Okamura,et al.  Measurement of the Tip and Friction Force Acting on a Needle during Penetration , 2002, MICCAI.

[3]  Aaron Fenster,et al.  Automatic needle segmentation in three-dimensional ultrasound images using two orthogonal two-dimensional image projections. , 2003, Medical physics.

[4]  Allison M. Okamura,et al.  Force modeling for needle insertion into soft tissue , 2004, IEEE Transactions on Biomedical Engineering.

[5]  Gregory S. Chirikjian,et al.  Steering flexible needles under Markov motion uncertainty , 2005, 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[6]  Robert J. Webster,et al.  Design Considerations for Robotic Needle Steering , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[7]  Jin Seob Kim,et al.  Nonholonomic Modeling of Needle Steering , 2006, Int. J. Robotics Res..

[8]  T. Podder,et al.  In vivo motion and force measurement of surgical needle intervention during prostate brachytherapy. , 2006, Medical physics.

[9]  Eun-Kyung Kim,et al.  Missed breast cancers at US-guided core needle biopsy: how to reduce them. , 2007, Radiographics : a review publication of the Radiological Society of North America, Inc.

[10]  Vinutha Kallem,et al.  Task-induced symmetry and reduction in kinematic systems with application to needle steering , 2007, 2007 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[11]  Rajni V. Patel,et al.  Needle insertion into soft tissue: a survey. , 2007, Medical engineering & physics.

[12]  Rajni V. Patel,et al.  Minimization of needle deflection in robot‐assisted percutaneous therapy , 2007, The international journal of medical robotics + computer assisted surgery : MRCAS.

[13]  Vinutha Kallem,et al.  Image-guided Control of Flexible Bevel-Tip Needles , 2007, Proceedings 2007 IEEE International Conference on Robotics and Automation.

[14]  V. Kallem,et al.  Integrated planning and image-guided control for planar needle steering , 2008, 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics.

[15]  K. Reed,et al.  Compensating for torsion windup in steerable needles , 2008, 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics.

[16]  Vinutha Kallem,et al.  Image Guidance of Flexible Tip-Steerable Needles , 2009, IEEE Transactions on Robotics.