Evaluation of transient time characteristics in the presence of capacitor switching

This paper focuses on the extraction of capacitor switching transient times and the evaluation of these time sequences. A unique automated voltage support experiment, responsible for the acquisition of capacitor switching transients and associated transient times, is presented. The network devices responsible for the creation of capacitor switching transients are analyzed. In the experiments presented, the device analyzed is the commonly used General Electric Type FKC-2 motorized oil switch. A 1/f/sup /spl beta// trend is identified in the transient time data sequences, a unique result to the authors' knowledge. This observation introduces the possibility of predicting the future occurrence of a capacitor switching event and, therefore, taking preventive actions to avoid harmful effects due to resulting transients.

[1]  T. E. Grebe Application of distribution system capacitor banks and their impact on power quality , 1995 .

[2]  M. Samotyj,et al.  Impact of utility switched capacitors on customer systems. II. Adjustable-speed drive concerns , 1991 .

[3]  Walter Willinger,et al.  On the self-similar nature of Ethernet traffic , 1993, SIGCOMM '93.

[4]  E. H. Camm,et al.  Evaluating capacitor-switching devices for preventing nuisance tripping of adjustable-speed drives due to voltage magnification , 1996 .

[5]  Dimitris G. Manolakis,et al.  INFRARED SCENE MODELING AND INTERPOLATION USING FRACTIONAL LÉVY STABLE MOTION , 1994 .

[6]  R. W. Alexander Synchronous Closing Control for Shunt Capacitors , 1985 .

[7]  C. Granger,et al.  AN INTRODUCTION TO LONG‐MEMORY TIME SERIES MODELS AND FRACTIONAL DIFFERENCING , 1980 .

[8]  M. D. Cox,et al.  Discrete wavelet analysis of power system transients , 1996 .

[9]  G. Wornell Wavelet-based representations for the 1/f family of fractal processes , 1993, Proc. IEEE.

[10]  J. S. Mayer,et al.  Wavelets and electromagnetic power system transients , 1996 .

[11]  Alex Pentland,et al.  Fractal-Based Description of Natural Scenes , 1984, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[12]  Imad Mougharbel,et al.  Minimal transient switching of capacitors , 1993 .

[13]  V. E. Wagner,et al.  Utility capacitor switching and adjustable-speed drives , 1991 .

[14]  Walter Willinger,et al.  Long-range dependence in variable-bit-rate video traffic , 1995, IEEE Trans. Commun..

[15]  M. J. Samotyj,et al.  Voltage sags in industrial systems , 1991, Conference Record. Industrial and Commercial Power Systems Technical Conference 1991.

[16]  Bruce J. West,et al.  Fractals in physiology and medicine. , 1987, The Yale journal of biology and medicine.

[17]  C. M. Fallon,et al.  Harmonics and transient overvoltages due to capacitor switching , 1992, [Proceedings] 1992 Rural Electric Power Conference. Papers presented at the 36th Annual Conference.

[18]  W. E. Reid Power quality issues-standards and guidelines , 1994 .

[19]  E. Gunther,et al.  A survey of distribution system power quality-preliminary results , 1995 .

[20]  M. Samotyj,et al.  Impact of utility switched capacitors on customer systems-magnification at low voltage capacitors , 1991 .

[21]  D. T. Rizy,et al.  Transient and Harmonic Voltages Associated with Automated Capacitor Switching on Distribution Systems , 1987, IEEE Transactions on Power Systems.

[22]  W. R. Nelson,et al.  Measuring and analyzing the impact of voltage and capacitor control with high speed data acquisition (distribution system) , 1989 .