Micro Wind Power Generator With Battery Energy Storage for Critical Load

In the micro-grid network, it is especially difficult to support the critical load without uninterrupted power supply. The proposed micro-wind energy conversion system with battery energy storage is used to exchange the controllable real and reactive power in the grid and to maintain the power quality norms as per International Electro-Technical Commission IEC-61400-21 at the point of common coupling. The generated micro-wind power can be extracted under varying wind speed and can be stored in the batteries at low power demand hours. In this scheme, inverter control is executed with hysteresis current control mode to achieve the faster dynamic switchover for the support of critical load. The combination of battery storage with micro-wind energy generation system (μ WEGS), which will synthesize the output waveform by injecting or absorbing reactive power and enable the real power flow required by the load. The system reduces the burden on the conventional source and utilizes μ WEGS and battery storage power under critical load constraints. The system provides rapid response to support the critical loads. The scheme can also be operated as a stand-alone system in case of grid failure like a uninterrupted power supply. The system is simulated in MATLAB/SIMULINK and results are presented.

[1]  Ziyad M. Salameh,et al.  Dynamic response of a stand-alone wind energy conversion system with battery energy storage to a wind gust , 1997 .

[2]  S. Bhattacharya,et al.  Control Strategies for Battery Energy Storage for Wind Farm Dispatching , 2009, IEEE Transactions on Energy Conversion.

[3]  Bhim Singh,et al.  Static Volt Ampere Reactive Compensator for Self-excited Induction Generator Feeding Dynamic Load , 2008 .

[4]  B. Singh,et al.  Analysis and design of STATCOM-based voltage regulator for self-excited induction generators , 2004, IEEE Transactions on Energy Conversion.

[5]  Poh Chiang Loh,et al.  A comparative analysis of multiloop voltage regulation strategies for single and three-phase UPS systems , 2003 .

[6]  P. Ramanathan A Statcom-Control Scheme for Grid Connected Wind Energy System for Power Quality Improvement , 2014 .

[7]  Prafulla Chandra Panda Power Quality Issues and its Mitigation Techniques , 2014 .

[8]  Shyh-Jier Huang,et al.  Design and Operation of Power Converter for Microturbine Powered Distributed Generator with Capacity Expansion Capability , 2008, IEEE Transactions on Energy Conversion.

[9]  E. Spooner,et al.  Grid Power Quality with Variable-Speed Wind Turbines , 2001, IEEE Power Engineering Review.

[10]  Zhenhua Jiang,et al.  Adaptive Control Strategy for Active Power Sharing in Hybrid Fuel Cell/Battery Power Sources , 2007, IEEE Transactions on Energy Conversion.

[11]  T. Nanahara,et al.  Analysis of data obtained in demonstration test about battery energy storage system to mitigate output fluctuation of wind farm , 2009, 2009 CIGRE/IEEE PES Joint Symposium Integration of Wide-Scale Renewable Resources Into the Power Delivery System.

[12]  A. Tapia,et al.  Proportional–Integral Regulator-Based Approach to Wind Farm Reactive Power Management for Secondary Voltage Control , 2007, IEEE Transactions on Energy Conversion.

[13]  V. Katic,et al.  Power Quality Problems Compensation With Universal Power Quality Conditioning System , 2007, IEEE Transactions on Power Delivery.

[14]  H. Akagi,et al.  State-of-Charge (SOC)-Balancing Control of a Battery Energy Storage System Based on a Cascade PWM Converter , 2009, IEEE Transactions on Power Electronics.

[15]  S.W. Mohod,et al.  Grid Power Quality with Variable Speed Wind Energy Conversion , 2006, 2006 International Conference on Power Electronic, Drives and Energy Systems.

[16]  Jan T. Bialasiewicz,et al.  Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey , 2006, IEEE Transactions on Industrial Electronics.

[17]  John E. Quaicoe,et al.  Analysis and design of a multiple feedback loop control strategy for single-phase voltage-source UPS inverters , 1996 .