Indirect Measurement of Switch Terms of a Vector Network Analyzer with Reciprocal Devices

This paper presents an indirect method for measuring the switch terms of a vector network analyzer (VNA) using at least three reciprocal devices, which do not need to be characterized beforehand. This method is particularly suitable for VNAs that use a three-sampler architecture, which allows for applying first-tier calibration methods based on the error box model. The proposed method was experimentally verified by comparing directly and indirectly measured switch terms and performing a multiline thru-reflect-line (TRL) calibration.

[1]  Ziad Hatab,et al.  Improving The Reliability of The Multiline TRL Calibration Algorithm , 2022, 2022 98th ARFTG Microwave Measurement Conference (ARFTG).

[2]  Noah D. Sauber,et al.  scikit-rf: An Open Source Python Package for Microwave Network Creation, Analysis, and Calibration [Speaker’s Corner] , 2022, IEEE Microwave Magazine.

[3]  Dylan F. Williams,et al.  The Relationship Between Switch-Term-Corrected Scattering-Parameters and Wave-Parameters Measured With a Two-Port Vector Network Analyzer , 2018, IEEE Microwave and Wireless Components Letters.

[4]  A. Rumiantsev,et al.  VNA calibration , 2008, IEEE Microwave Magazine.

[5]  Leonard Hayden,et al.  VNA error model conversion for N-port calibration comparison , 2007, 2007 69th ARFTG Conference.

[6]  L. Hayden,et al.  An enhanced Line-Reflect-Reflect-Match calibration , 2006, 2006 67th ARFTG Conference.

[7]  S. Vandenberghe,et al.  Identifying error-box parameters from the twelve-term vector network analyzer error model , 2002, 60th ARFTG Conference Digest, Fall 2002..

[8]  Roger B. Marks,et al.  Formulations of the Basic Vector Network Analyzer Error Model including Switch-Terms , 1997, 50th ARFTG Conference Digest.

[9]  Roger B. Marks,et al.  Two-Tier Multiline TRL for Calibration of Low-Cost Network Analyzers , 1995, 46th ARFTG Conference Digest.

[10]  G. Strang The Fundamental Theorem of Linear Algebra , 1993 .

[11]  A. Ferrero,et al.  Two-port network analyzer calibration using an unknown 'thru' , 1992, IEEE Microwave and Guided Wave Letters.

[12]  R. Marks A multiline method of network analyzer calibration , 1991 .

[13]  B. Schiek,et al.  Thru-Match-Reflect: One Result of a Rigorous Theory for De-Embedding and Network Analyzer Calibration , 1988, 1988 18th European Microwave Conference.

[14]  G. F. Engen,et al.  Thru-Reflect-Line: An Improved Technique for Calibrating the Dual Six-Port Automatic Network Analyzer , 1979 .