Biosensors in Monitoring Water Quality and Safety: An Example of a Miniaturizable Whole-Cell Based Sensor for Hg2+ Optical Detection in Water

Inorganic mercury (Hg2+) pollution of water reserves, especially drinking water, is an important issue in the environmental and public health field. Mercury is reported to be one of the most dangerous elements in nature since its accumulation and ingestion can lead to a series of permanent human diseases, affecting the kidneys and central nervous system. All the conventional approaches for assaying Hg2+ have some limitations in terms of bulky instruments and the cost and time required for the analysis. Here, we describe a miniaturizable and high-throughput bioluminescence sensor for Hg2+ detection in water, which combines the specificity of a living bacterial Hg2+ reporter cell, used as sensing element, with the performance of a silicon photomultiplier, used as optical detector. The proposed system paves the basis for portable analysis and low reactants consumption. The aim of the work is to propose a sensing strategy for total inorganic mercury evaluation in water. The proposed system can lay the basis for further studies and validations in order to develop rapid and portable technology that can be used in situ providing remote monitoring.

[1]  Sebania Libertino,et al.  Study of a Miniaturizable System for Optical Sensing Application to Human Cells , 2019, Applied Sciences.

[2]  Sabrina Conoci,et al.  Sulfide Species Optical Monitoring by a Miniaturized Silicon Photomultiplier , 2018, Sensors.

[3]  C. Piemonte,et al.  High-Density Silicon Photomultipliers: Performance and Linearity Evaluation for High Efficiency and Dynamic-Range Applications , 2018, IEEE Journal of Quantum Electronics.

[4]  M. F. Santangelo,et al.  Integrating printed microfluidics with silicon photomultipliers for miniaturised and highly sensitive ATP bioluminescence detection. , 2018, Biosensors & bioelectronics.

[5]  Lu Yan,et al.  The Application of Whole Cell-Based Biosensors for Use in Environmental Analysis and in Medical Diagnostics , 2017, Sensors.

[6]  F. Valeriani,et al.  Swimming attendance during childhood and development of asthma: Meta‐analysis , 2017, Pediatrics international : official journal of the Japan Pediatric Society.

[7]  David L. Taylor,et al.  Mercury contamination in Southern New England coastal fisheries and dietary habits of recreational anglers and their families: Implications to human health and issuance of consumption advisories. , 2017, Marine pollution bulletin.

[8]  Sabrina Conoci,et al.  Si Photomultipliers for Bio-Sensing Applications , 2016, IEEE Journal of Selected Topics in Quantum Electronics.

[9]  Jan Roelof van der Meer,et al.  An automated microreactor for semi-continuous biosensor measurements. , 2016, Lab on a chip.

[10]  Oa Us Epa Mercury and Air Toxics Standards (MATS) , 2015 .

[11]  G. Thouand,et al.  Detection of Metal and Organometallic Compounds with Bioluminescent Bacterial Bioassays. , 2015, Advances in biochemical engineering/biotechnology.

[12]  S. Ferreira,et al.  Analytical strategies of sample preparation for the determination of mercury in food matrices — A review , 2015 .

[13]  Gérard Donzé,et al.  Regulations concerning natural swimming ponds in Europe: considerations on public health issues. , 2014, Journal of water and health.

[14]  R. Álvarez-Puebla,et al.  Chemical speciation of heavy metals by surface-enhanced Raman scattering spectroscopy: identification and quantification of inorganic- and methyl-mercury in water. , 2014, Nanoscale.

[15]  Pierre Gros,et al.  Electrochemical sensors and devices for heavy metals assay in water: the French groups' contribution , 2014, Front. Chem..

[16]  Sabrina Conoci,et al.  Optical and Electrical Si-Based Biosensors: Fabrication and Trasduction Issues , 2014 .

[17]  Xingjiu Huang,et al.  Voltammetric determination of mercury(II) , 2013 .

[18]  A. Zherdev,et al.  Antibody-Based Biosensors , 2013 .

[19]  Jan Roelof van der Meer,et al.  Electrochemical As(III) whole-cell based biochip sensor. , 2013, Biosensors & bioelectronics.

[20]  S. Baek,et al.  Speciation and determination of mercury by various analytical techniques , 2013 .

[21]  Sebania Libertino,et al.  Silicon photomultiplier device architecture with dark current improved to the ultimate physical limit , 2013 .

[22]  Jianhua Wang,et al.  Recent advances in flow-based sample pretreatment for the determination of metal species by atomic spectrometry , 2013 .

[23]  M. Albrow,et al.  Electro-Optical Performances of p-on-n and n-on-p Silicon Photomultipliers , 2012, IEEE Transactions on Electron Devices.

[24]  V. Preedy,et al.  Biosensors and environmental health , 2012 .

[25]  C. Zheng,et al.  Determination and speciation of mercury in environmental and biological samples by analytical atomic spectrometry , 2012 .

[26]  E. Flores,et al.  Total Mercury, Inorganic Mercury and Methyl Mercury Determination in Red Wine , 2012, Food Analytical Methods.

[27]  Xingjiu Huang,et al.  Electropolymerized surface ion imprinting films on a gold nanoparticles/single-wall carbon nanotube nanohybrids modified glassy carbon electrode for electrochemical detection of trace mercury(II) in water. , 2012, Analytica chimica acta.

[28]  A. Türker Separation, Preconcentration and Speciation of Metal Ions by Solid Phase Extraction , 2012 .

[29]  Xingjiu Huang,et al.  Selective adsorption toward toxic metal ions results in selective response: electrochemical studies on a polypyrrole/reduced graphene oxide nanocomposite. , 2012, Chemical communications.

[30]  R. Kanzaki,et al.  Determination of Organic and Inorganic Mercury Species as Emetine Dithiocarbamate Complexes by High-Performance Liquid Chromatography with Electrogenerated Tris(2,2′-bipyridine)ruthenium(III) Chemiluminescence Detection , 2011 .

[31]  S. Chung,et al.  A reliable method to determine methylmercury and ethylmercury simultaneously in foods by gas chromatography with inductively coupled plasma mass spectrometry after enzymatic and acid digestion. , 2011, Journal of chromatography. A.

[32]  Xingjiu Huang,et al.  Stripping voltammetric detection of mercury(II) based on a surface ion imprinting strategy in electropolymerized microporous poly(2-mercaptobenzothiazole) films modified glassy carbon electrode. , 2011, Analytica chimica acta.

[33]  S. Belkin,et al.  Where microbiology meets microengineering: design and applications of reporter bacteria , 2010, Nature Reviews Microbiology.

[34]  Stephan Hann,et al.  Environmental application of elemental speciation analysis based on liquid or gas chromatography hyphenated to inductively coupled plasma mass spectrometry--a review. , 2010, Analytica chimica acta.

[35]  Paul Worsfold,et al.  Methods for the determination and speciation of mercury in natural waters--a review. , 2010, Analytica chimica acta.

[36]  Gerald W. Bracey Basic Information , 2009 .

[37]  Chunhai Fan,et al.  Highly sensitive electrochemical sensor for mercury(II) ions by using a mercury-specific oligonucleotide probe and gold nanoparticle-based amplification. , 2009, Analytical chemistry.

[38]  Hannah A. Shayler,et al.  Mercury Contamination in Sport Fish in the Northeastern United States: Considerations for Future Data Collection , 2009 .

[39]  H. Hashemi-Moghaddam,et al.  Sensitive mercury speciation by reversed-phase column high-performance liquid chromatography with UV-visible detection after solid-phase extraction using 6-mercaptopurine and dithizone. , 2008, Journal of AOAC International.

[40]  Donna Mergler,et al.  Methylmercury Exposure and Health Effects in Humans: A Worldwide Concern , 2007, Ambio.

[41]  M. Vieira,et al.  Evaluation of slurry preparation procedures for the determination of mercury by axial view inductively coupled plasma optical emission spectrometry using on-line cold vapor generation☆ , 2005 .

[42]  Laurent Giovangrandi,et al.  Sensitivity of cell-based biosensors to environmental variables. , 2005, Biosensors & bioelectronics.

[43]  Marko Virta,et al.  Detection of bioavailable heavy metals in EILATox‐Oregon samples using whole‐cell luminescent bacterial sensors in suspension or immobilized onto fibre‐optic tips , 2004, Journal of applied toxicology : JAT.

[44]  Susan M. Miller,et al.  Bacterial mercury resistance from atoms to ecosystems. , 2003, FEMS microbiology reviews.

[45]  N. Brown,et al.  The MerR family of transcriptional regulators. , 2003, FEMS microbiology reviews.

[46]  T. Barkay,et al.  mer -Mediated Resistance and Volatilization of Hg(II) Under Anaerobic Conditions , 2002 .

[47]  J. Bartram,et al.  HUMAN HEALTH ASPECTS , 1999 .

[48]  A O Summers,et al.  A mer-lux transcriptional fusion for real-time examination of in vivo gene expression kinetics and promoter response to altered superhelicity , 1992, Journal of bacteriology.

[49]  W. Kröger,et al.  Recommendations , 1915, Nature.

[50]  Pimchai Chaiyen,et al.  Structure, Mechanism, and Mutation of Bacterial Luciferase. , 2016, Advances in biochemical engineering/biotechnology.

[51]  A. J. Curtius,et al.  Determination of As and Hg in acetic acid extract by vapor generation coupled to atomic spectrometry for solid waste classification , 2013 .

[52]  C. Dinu,et al.  Advanced analytical methods for mercury determination in slightly contaminated water samples , 2013 .

[53]  K. Gürsan,et al.  Portable Biosensing of Food Toxicants and Environmental Pollutants , 2013 .

[54]  F. Barbosa,et al.  Methylmercury and inorganic mercury determination in blood by using liquid chromatography with inductively coupled plasma mass spectrometry and a fast sample preparation procedure. , 2010, Talanta.

[55]  Man Bock Gu,et al.  Whole-cell-based biosensors for environmental biomonitoring and application. , 2004, Advances in biochemical engineering/biotechnology.