Implantable Concanavlin a Based Sensors for Interstitial Fluid Glucose Sensing in Diabetics

Currently, 6.2% of the United States population has been diagnosed with diabetes1. Of the estimated 17 million diabetics, 90% of them are insulin resistant2. Diabetes is commonly split into two categories depending on the cause of the disease. Type 1 diabetes, traditionally termed juvenile, is marked by a failure of the B-cells in the endocrine portion of the pancreas to properly synthesize insulin resulting in improper control of blood glucose levels. Type 2 diabetes, traditionally classified as late onset, develops when organs and cells in the body become immune to native insulin resulting in dramatic oscillations in blood sugar2–4. Type 1 diabetics regulate their blood sugar by either consuming a glucose rich food, if blood sugar is low ( 150 mg/dL)1. Type 2 diabetics, being resistant to insulin therapy, must regulate their blood sugar through dietary control and through the aid of commercially available drug treatments1. All diabetics are recommended to monitor their blood sugar often to avoid immediate threats attributed to high or low blood sugar such as dizziness, coma, or even death5. New research has shown that continuous monitoring of blood sugar with tight blood glucose control (as close to normal as possible, 70–150 mg/dL) can substantially reduce the risk of developing afflictions associated with prolonged misregulation of blood sugar5. These afflictions include kidney, liver, and heart disease, amputations due to poor circulation and blindness due to retinopathy5.

[1]  J. Hubbell,et al.  Densely crosslinked polymer networks of poly(ethylene glycol) in trimethylolpropane triacrylate for cell-adhesion-resistant surfaces. , 1995, Journal of biomedical materials research.

[2]  S. Genuth,et al.  The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. , 1993, The New England journal of medicine.

[3]  Michael J McShane,et al.  Potential for glucose monitoring with nanoengineered fluorescent biosensors. , 2002, Diabetes technology & therapeutics.

[4]  J. Hubbell,et al.  In Vitro and in Vivo Performance of Porcine Islets Encapsulated in Interfacially Photopolymerized Poly(Ethylene Glycol) Diacrylate Membranes , 1999, Cell transplantation.

[5]  Joseph R Lakowicz,et al.  Ophthalmic glucose sensing: a novel monosaccharide sensing disposable and colorless contact lens. , 2004, The Analyst.

[6]  G L Coté,et al.  Noninvasive and minimally-invasive optical monitoring technologies. , 2001, The Journal of nutrition.

[7]  Frederick H. Martini,et al.  Fundamentals of Anatomy & Physiology , 1989 .

[8]  J. Lakowicz Principles of fluorescence spectroscopy , 1983 .

[9]  T. B. Blank,et al.  Noninvasive prediction of glucose by near-infrared diffuse reflectance spectroscopy. , 1999, Clinical chemistry.

[10]  Jeffrey A. Hubbell,et al.  Photopolymerized hydrogel materials for drug delivery applications , 1995 .

[11]  John Pickup,et al.  In vivo glucose sensing for diabetes management: progress towards non-invasive monitoring , 1999, BMJ.

[12]  A Heller,et al.  Biocompatible, glucose-permeable hydrogel for in situ coating of implantable biosensors. , 1997, Biomaterials.

[13]  J. A. Hubbell,et al.  Separation of the arterial wall from blood contact using hydrogel barriers reduces intimal thickening after balloon injury in the rat: the roles of medial and luminal factors in arterial healing. , 1996, Proceedings of the National Academy of Sciences of the United States of America.

[14]  H. Naito,et al.  Accuracy of the One Touch II whole blood glucose analyzer when used by analysts with diverse technical backgrounds. , 1993, The Journal of family practice.

[15]  Binghe Wang,et al.  Progress in Boronic Acid-Based Fluorescent Glucose Sensors , 2004, Journal of Fluorescence.

[16]  M A Arnold,et al.  Non-invasive glucose monitoring. , 1996, Current opinion in biotechnology.

[17]  Bennett L. Ibey,et al.  In vivo monitoring of blood glucose using poly(ethylene glycol) microspheres , 2003, SPIE BiOS.

[18]  H Szmacinski,et al.  Lifetime-based sensing of glucose using energy transfer with a long lifetime donor. , 1997, Analytical biochemistry.

[19]  G. Coté,et al.  Noninvasive glucose sensing utilizing a digital closed-loop polarimetric approach , 1997, IEEE Transactions on Biomedical Engineering.

[20]  C. C. Francis,et al.  Fundamentals of Anatomy , 1938 .

[21]  G. S. Wilson,et al.  Interstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoring. , 2000, American journal of physiology. Endocrinology and metabolism.

[22]  M A Arnold,et al.  Evaluation of measurement sites for noninvasive blood glucose sensing with near-infrared transmission spectroscopy. , 1999, Clinical chemistry.

[23]  Igor K Lednev,et al.  High ionic strength glucose-sensing photonic crystal. , 2003, Analytical chemistry.

[24]  Joseph R. Lakowicz,et al.  A Glucose Sensing Contact Lens: A Non-Invasive Technique for Continuous Physiological Glucose Monitoring , 2003, Journal of Fluorescence.

[25]  Michael J. McShane,et al.  Implantable biosensors: analysis of fluorescent light propagation through skin , 2001, SPIE BiOS.

[26]  J C Pickup,et al.  A time-resolved near-infrared fluorescence assay for glucose: opportunities for trans-dermal sensing. , 2000, Journal of photochemistry and photobiology. B, Biology.

[27]  R. Potts,et al.  Physiological differences between interstitial glucose and blood glucose measured in human subjects. , 2003, Diabetes care.

[28]  G. Coté,et al.  Glucose monitoring using implanted fluorescent microspheres , 2000, IEEE Engineering in Medicine and Biology Magazine.

[29]  A. Axel,et al.  Mass transfer in rapidly photopolymerized poly(ethylene glycol) hydrogels used for chemical sensing , 2001 .

[30]  Michael J. McShane,et al.  Progress toward implantable fluorescence-based sensors for monitoring glucose levels in interstitial fluid , 2000, Photonics West - Biomedical Optics.

[31]  Allyson Beuhler,et al.  In vitro long-term performance study of a near-infrared fluorescence affinity sensor for glucose monitoring. , 2004, Biosensors & bioelectronics.

[32]  R. Guy,et al.  Reverse Iontophoresis: Noninvasive Glucose Monitoring in Vivo in Humans , 1995, Pharmaceutical Research.

[33]  J. Hubbell,et al.  Adhesion prevention with ancrod released via a tissue-adherent hydrogel. , 1996, The Journal of surgical research.

[34]  Kevin H. Hazen,et al.  Measurement of Glucose in Water with First-Overtone Near-Infrared Spectra , 1998 .

[35]  J. Hubbell,et al.  Inhibition of thrombosis and intimal thickening by in situ photopolymerization of thin hydrogel barriers. , 1994, Proceedings of the National Academy of Sciences of the United States of America.

[36]  David L. Andrews,et al.  Resonance Energy Transfer , 1999 .

[37]  L. Rovati,et al.  New optical scheme for a polarimetric-based glucose sensor. , 2004, Journal of biomedical optics.

[38]  Sohi Rastegar,et al.  Monte Carlo modeling for implantable fluorescent analyte sensors , 2000, IEEE Transactions on Biomedical Engineering.

[39]  J. Schultz,et al.  Fiber-optic biosensors based on fluorescence energy transfer. , 1988, Talanta.

[40]  J. Lakowicz,et al.  A new highly fluorescent probe for monosaccharides based on a donor-acceptor diphenyloxazole. , 2001, Chemical communications.

[41]  J. C. Norrild,et al.  Design, synthesis and structure of new potential electrochemically active boronic acid-based glucose sensors , 2002 .

[42]  Kevin H. Hazen,et al.  Measurement of glucose and other analytes in undiluted human serum with near-infrared transmission spectroscopy , 1998 .

[43]  Russell O. Potts,et al.  Measurement of glucose in diabetic subjects using noninvasive transdermal extraction , 1995, Nature Medicine.

[44]  P. Connolly,et al.  Opportunities at the skin interface for continuous patient monitoring: a reverse iontophoresis model tested on lactate and glucose. , 2002, IEEE transactions on nanobioscience.

[45]  M A Arnold,et al.  Strategies for coupling digital filtering with partial least-squares regression: application to the determination of glucose in plasma by Fourier transform near-infrared spectroscopy. , 1993, Analytical chemistry.

[46]  J. A. Hubbell,et al.  Optimization of photopolymerized bioerodible hydrogel properties for adhesion prevention. , 1994, Journal of biomedical materials research.

[47]  David L. Meadows,et al.  Design, manufacture and characterization of an optical fiber glucose affinity sensor based on an homogeneous fluorescence energy transfer assay system , 1993 .

[48]  G. Whitesides,et al.  Self-assembled organic monolayers: model systems for studying adsorption of proteins at surfaces , 1991, Science.

[49]  R. Guy A sweeter life for diabetics? , 1995, Nature Medicine.

[50]  Joseph R. Lakowicz,et al.  Optical sensing of glucose using phase-modulation fluorimetry , 1993 .

[51]  Joseph R Lakowicz,et al.  Noninvasive continuous monitoring of physiological glucose using a monosaccharide-sensing contact lens. , 2004, Analytical chemistry.

[52]  David C. Klonoff,et al.  Noninvasive Blood Glucose Monitoring , 1997, Diabetes Care.

[53]  D. Ubbink,et al.  Influence of repetitive finger puncturing on skin perfusion and capillary blood analysis in patients with diabetes mellitus. , 1999, Clinical chemistry.

[54]  J. Schultz,et al.  Affinity Sensor: A New Technique for Developing Implantable Sensors for Glucose and Other Metabolites , 1982, Diabetes Care.

[55]  Jeffrey A. Hubbell,et al.  Rapid photopolymerization of immunoprotective gels in contact with cells and tissue , 1992 .

[56]  Bernhard Lendl,et al.  Application of Mid-Infrared Transmission Spectrometry to the Direct Determination of Glucose in Whole Blood , 1998 .

[57]  Joseph R. Lakowicz,et al.  Optical assay for glucose based on the luminescnence decay time of the long wavelength dye Cy5™. , 1997, Sensors and actuators. B, Chemical.

[58]  G L Coté,et al.  A fluorescence-based glucose biosensor using concanavalin A and dextran encapsulated in a poly(ethylene glycol) hydrogel. , 1999, Analytical chemistry.

[59]  L. Brand,et al.  Resonance energy transfer: methods and applications. , 1994, Analytical biochemistry.

[60]  Ashok Gowda,et al.  Fluorescence resonance energy transfer-based near-infrared fluorescence sensor for glucose monitoring. , 2004, Diabetes technology & therapeutics.

[61]  H. Bittiger,et al.  Concanavalin A as a tool , 1976 .

[62]  T. James,et al.  Boronic Acid Based Modular Fluorescent Sensors for Glucose , 2004, Journal of Fluorescence.

[63]  S. Skeie,et al.  Instruments for self-monitoring of blood glucose: comparisons of testing quality achieved by patients and a technician. , 2002, Clinical chemistry.

[64]  A. Bernadac,et al.  Temperature effects on the concanavalin A molecule and on concanavalin A binding. , 1974, Biochimica et biophysica acta.

[65]  J. Schultz,et al.  A fluorescence affinity hollow fiber sensor for continuous transdermal glucose monitoring. , 2000, Analytical chemistry.

[66]  Brent D. Cameron,et al.  Optical polarimetry applied to the development of a noninvasive in-vivo glucose monitor , 2000, Photonics West - Biomedical Optics.

[67]  S. Colberg,et al.  Use of the noninvasive GlucoWatch Biographer during exercise of varying intensity. , 2004, Diabetes technology & therapeutics.

[68]  Shu-Jen Yeh,et al.  Monitoring blood glucose changes in cutaneous tissue by temperature-modulated localized reflectance measurements. , 2003, Clinical chemistry.

[69]  L. Heinemann,et al.  Sensors for glucose monitoring: technical and clinical aspects , 2001, Diabetes/metabolism research and reviews.

[70]  J. Lakowicz,et al.  On the Possibility of Glucose Sensing Using Boronic Acid and a Luminescent Ruthenium Metal-Ligand Complex , 2002, Journal of Fluorescence.

[71]  D. Cordes,et al.  Continuous glucose sensing with a fluorescent thin-film hydrogel. , 2003, Angewandte Chemie.

[72]  Jerome S. Schultz,et al.  Competitive-binding assay method based on fluorescence quenching of ligands held in close proximity by a multivalent receptor , 1997 .

[73]  L Wang,et al.  MCML--Monte Carlo modeling of light transport in multi-layered tissues. , 1995, Computer methods and programs in biomedicine.

[74]  M. Pishko,et al.  Release of protein from highly cross-linked hydrogels of poly(ethylene glycol) diacrylate fabricated by UV polymerization. , 2001, Biomaterials.

[75]  G. Coté,et al.  Effect of temperature, pH, and corneal birefringence on polarimetric glucose monitoring in the eye. , 2002, Journal of biomedical optics.

[76]  A. Clarke,et al.  The interaction of concanavalin A with blood-group-substance glycoproteins from human secretions. , 1971, The Biochemical journal.