Weak Grid Intertie WEGS With Hybrid Generalized Integrator for Power Quality Improvement

The wind energy generating system (WEGS) in this paper, aims to provide the required active peak power without high frequency fluctuations even under variable wind speed conditions. The generator speed is adjusted according to the intermittent wind speeds through two voltage source converters (VSCs) connected back to back, namely, machine-side VSC (MSVSC) and utility grid side VSC (UGVSC) across the dc-link capacitor. In this paper, the hybrid generalized integrator control is proposed for switching UGVSC and providing dc offset rejection and immunity against oscillatory errors due to subharmonics, thereby improving the power quality (PQ). Fuzzy logic controller (FLC) is implemented for the speed control of the salient pole synchronous generator (SG) driven by the wind turbine. The FLC provides the tracking of the reference speed under high overshoot transient conditions and narrow bandwidth. The switching of MSVSC is obtained by field oriented control. The dynamic performance is improved by the wind feed-forward term, which reduces the oscillation, ensuring balanced and sinusoidal grid currents. The generated power from the WEGS is fed to the grid. The weak grid conditions, namely, grid voltage unbalance, voltage sag, voltage swell, and grid voltage distortion, are considered. The performance of the system is tested on a laboratory prototype. Test results provide the effectiveness of the system with increased wind penetration and performance under weak grid conditions. Moreover, improving the PQ, the grid current total harmonic distortion meets the requirement of IEEE-519 standard, and is found to be less than 5%.

[1]  Maurizio Cirrincione,et al.  Neural MPPT Control of Wind Generators With Induction Machines Without Speed Sensors , 2011, IEEE Transactions on Industrial Electronics.

[2]  Bo Zhou,et al.  Principle and Stability Analysis of an Improved Self-Sensing Control Strategy for Surface-Mounted PMSM Drives Using Second-Order Generalized Integrators , 2018, IEEE Transactions on Energy Conversion.

[3]  M. Karimi-Ghartemani,et al.  Addressing DC Component in PLL and Notch Filter Algorithms , 2012, IEEE Transactions on Power Electronics.

[4]  Frede Blaabjerg,et al.  Impedance Analysis of SOGI-FLL-Based Grid Synchronization , 2017, IEEE Transactions on Power Electronics.

[5]  Kit Po Wong,et al.  A Sliding Mode Based Damping Control of DFIG for Interarea Power Oscillations , 2017, IEEE Transactions on Sustainable Energy.

[6]  Marcelo Godoy Simões,et al.  Power Quality Enhancement for a Grid Connected Wind Turbine Energy System , 2017, IEEE Transactions on Industry Applications.

[7]  Frede Blaabjerg,et al.  Improved Nonlinear Flux Observer-Based Second-Order SOIFO for PMSM Sensorless Control , 2019, IEEE Transactions on Power Electronics.

[8]  Sukanta Das,et al.  Implementation of reactive power-based MRAS for sensorless speed control of brushless doubly fed reluctance motor drive , 2018 .

[9]  Jingtian Bi,et al.  Small-signal angular stability of power system as affected by grid-connected variable speed wind generators- A survey of recent representative works , 2017 .

[10]  Fangxing Li,et al.  Maximum power point tracking strategy for large-scale wind generation systems considering wind turbine dynamics , 2015, 2015 IEEE Power & Energy Society General Meeting.

[11]  M. P. Selvan,et al.  A Modified Active Power Control Scheme for Enhanced Operation of PMSG-Based WGs , 2018 .

[12]  K. M. Muttaqi,et al.  An Effective Power Dispatch Control Strategy to Improve Generation Schedulability and Supply Reliability of a Wind Farm Using a Battery Energy Storage System , 2015, IEEE Transactions on Sustainable Energy.

[13]  M. A. Rahman,et al.  Analysis of field oriented control for permanent magnet hysteresis synchronous motors , 1993 .

[14]  Mohammad Shahidehpour,et al.  Application of Multi-Resonator Notch Frequency Control for Tracking the Frequency in Low Inertia Microgrids Under Distorted Grid Conditions , 2019, IEEE Transactions on Smart Grid.

[15]  Zhe Zhang,et al.  A Grid Synchronization PLL Method Based on Mixed Second- and Third-Order Generalized Integrator for DC Offset Elimination and Frequency Adaptability , 2018, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[16]  Zhifang Wang,et al.  Impacts of Wind Power Uncertainty on Grid Vulnerability to Cascading Overload Failures , 2018, IEEE Transactions on Sustainable Energy.

[17]  Frede Blaabjerg,et al.  A Novel Flux Estimator Based on Multiple Second-Order Generalized Integrators and Frequency-Locked Loop for Induction Motor Drives , 2017, IEEE Transactions on Power Electronics.

[18]  B. Fahimi,et al.  Position sensorless control , 2004, IEEE Industry Applications Magazine.

[19]  Paolo Mattavelli,et al.  Re-Investigation of Generalized Integrator Based Filters From a First-Order-System Perspective , 2016, IEEE Access.

[20]  Yi Zhang,et al.  Reliability Modeling and Control Schemes of Composite Energy Storage and Wind Generation System With Adequate Transmission Upgrades , 2011, IEEE Transactions on Sustainable Energy.

[21]  Václav Smídl,et al.  Advantages of Square-Root Extended Kalman Filter for Sensorless Control of AC Drives , 2012, IEEE Transactions on Industrial Electronics.

[22]  Huiqing Wen,et al.  DC Offset Rejection Improvement in Single-Phase SOGI-PLL Algorithms: Methods Review and Experimental Evaluation , 2017, IEEE Access.

[23]  Jon Are Suul,et al.  Voltage-Sensor-Less Synchronization to Unbalanced Grids by Frequency-Adaptive Virtual Flux Estimation , 2012, IEEE Transactions on Industrial Electronics.

[24]  José P. da Silva,et al.  Simulation of a Fuzzy Control Applied to a Variable Speed Wind System Connected to the Electrical Network , 2018 .

[25]  Tukaram Moger,et al.  Fuzzy logic approach for reactive power coordination in grid connected wind farms to improve steady state voltage stability , 2017 .

[26]  Fumiyuki Adachi,et al.  Published online in Wiley Online Library (wileyonlinelibrary.com). DOI: 10.1002/dac.2517 Adaptive system identification using robust LMS/F algorithm , 2022 .

[27]  Jamal Rizk,et al.  Estimation of commutation instances using back emf mapping for sensorless control of brushless permanent magnet motors , 2013 .

[28]  Alireza Khaligh,et al.  Energy Harvesting: Solar, Wind, and Ocean Energy Conversion Systems , 2009 .

[29]  Uma Govindarajan,et al.  Active and reactive power regulation in grid connected wind energy systems with permanent magnet synchronous generator and matrix converter , 2014 .