Development of Sensor System for Effective Evaluation of Surgical Skill

This paper describes a new sensor system for effective evaluation of surgical skill. This system used photo interrupter in order to detect the movement of skin dummy during suture placement. Experimental results show that the data obtained from this sensor are significantly different among surgeons and non-medical volunteers from a few aspects. We proposed the differences as evaluation parameters to evaluate suture skill using this system. The effectiveness of this evaluation parameters was confirmed when surgeons' data and non-medical volunteers' data are divided effectively using Discriminant Function Analysis. One of the advantages of this system is it can be develop at low cost. In future, this sensor system will be embedded in patient robot application

[1]  S. Seki Techniques for better suturing , 1988, The British journal of surgery.

[2]  A. Cuschieri,et al.  Psychomotor skills for endoscopic manipulations: differing abilities between right and left-handed individuals. , 1997, Annals of surgery.

[3]  A. Cuschieri,et al.  Influence of direction of view, target‐to‐endoscope distance and manipulation angle on endoscopic knot tying , 1997, The British journal of surgery.

[4]  J. Rosser,et al.  Objective evaluation of a laparoscopic surgical skill program for residents and senior surgeons. , 1998, Archives of surgery.

[5]  A. Cuschieri,et al.  Task performance in endoscopic surgery is influenced by location of the image display. , 1998, Annals of surgery.

[6]  M. Raibert,et al.  Measuring and developing suturing technique with a virtual reality surgical simulator. , 1999, Journal of the American College of Surgeons.

[7]  B. Hannaford,et al.  Force controlled and teleoperated endoscopic grasper for minimally invasive surgery-experimental performance evaluation , 1999, IEEE Transactions on Biomedical Engineering.

[8]  A. Cuschieri,et al.  Effect of intracorporeal-extracorporeal instrument length ratio on endoscopic task performance and surgeon movements. , 2000, Archives of surgery.

[9]  Blake Hannaford,et al.  Markov modeling of minimally invasive surgery based on tool/tissue interaction and force/torque signatures for evaluating surgical skills , 2001, IEEE Transactions on Biomedical Engineering.

[10]  Masaaki Mochimaru,et al.  Surgical Skill Evaluation by Force Data for Endoscopic Sinus Surgery Training System , 2002, MICCAI.

[11]  Hiroyuki Shinoda,et al.  A study on tactile resolution of human skin , 2002, Proceedings of the 41st SICE Annual Conference. SICE 2002..

[12]  Mitsuo Umezu,et al.  Development of carbon microcoils (CMC) sensor system with high sensitivity for effective acquisition of tactile information , 2005, 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[13]  R. Satava,et al.  The Use of Surgical Simulators to Reduce Errors , 2005 .

[14]  S. Seki Suturing techniques of individual surgeons —Differences in accuracy and mechanics— , 1989, The Japanese journal of surgery.