First Evaluation of Neutron Induced Single Event Effects on the CMS Barrel Muon Electronics

Neutron irradiation tests of the available electronics for the CMS barrel muon detector were performed using thermal and fast neutrons. The Single Event Upset rates on static RAMs were measured, while upper limits are derived for devices having experienced no failure. The results are used to guess the mean time between failures in the whole barrel muon detector.