The Diagnostic Accuracy of the 64-slice Multi-detector CT Coronary Angiography for the Assessment of Coronary Artery Stenosis in Symptomatic Patients

Purpose: We evaluated the diagnostic accuracy of a 64-slice multi-detector CT (MDCT) coronary angiography against a conventional coronary angiography (CCA) for the detection of significant stenosis (≥50% lumen diameter narrowing). Materials and Methods: Sixty-four patients underwent a MDCT and a subsequent CCA to evaluate the presence of atypical chest pain or suspected coronary artery disease (CAD). A MDCT angiography was performed using a 64-slice MDCT-scanner (Sensation 64, slice collimation 32×0.6 mm). The coronary artery segments were classified according to a 15-segment model. The sensitivity, specificity, and diagnostic accuracy of the 64-slice MDCT for the detection or exclusion of significant CAD were calculated on a per-segment and per-patient basis. Results: Fifty-nine of the 64 (92%) coronary CT angiograms were of diagnostic image quality with 93.5% (809 of 865) of the coronary segments assessable by CT angiography. One-hundred two (12.6%) segments showed significant stenosis by CCA. Stenosis of 50% or greater was detected by sensitivity, specificity, accuracy, positive predictive valve, and negative predictive value on a per segment basis (89%, 99%, 97%, 90%, and 98%, respectively) and a per-patient basis (96%, 69%, 90%, 92%, and 82%, respectively). Conclusion: The 64-slice MDCT coronary angiography demonstrated a high diagnostic accuracy for both the per-segment and per-patient analyses for this symptomatic patient group.

[1]  Jiang Hsieh,et al.  Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose. , 2008, Radiology.

[2]  William Wijns,et al.  Diagnostic performance of multidetector CT angiography for assessment of coronary artery disease: meta-analysis. , 2007, Radiology.

[3]  C. Herzog,et al.  Coronary CT angiography. , 2007, Radiology.

[4]  A. Taştan,et al.  Detection of significant coronary artery stenosis with 64-section MDCT angiography. , 2007, European journal of radiology.

[5]  Georg Mühlenbruch,et al.  Cardiac CT: coronary arteries and beyond , 2007, European Radiology.

[6]  T. Seyfarth,et al.  Diagnostic value of 64-slice multi-detector row cardiac CTA in symptomatic patients , 2007, European Radiology.

[7]  Jonathan Lessick,et al.  Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis. , 2006, JAMA.

[8]  Konstantin Nikolaou,et al.  Accuracy of 64-MDCT in the diagnosis of ischemic heart disease. , 2006, AJR. American journal of roentgenology.

[9]  Gabriel P. Krestin,et al.  Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris , 2006, European Radiology.

[10]  S. Achenbach,et al.  Detection of coronary artery stenoses using multi-detector CT with 16 x 0.75 collimation and 375 ms rotation. , 2005, European heart journal.

[11]  S. Achenbach,et al.  Comparison of the degree of coronary stenoses by multidetector computed tomography versus by quantitative coronary angiography. , 2005, The American journal of cardiology.

[12]  Theo Stijnen,et al.  Intravenous contrast material administration at helical 16-detector row CT coronary angiography: effect of iodine concentration on vascular attenuation. , 2005, Radiology.

[13]  S. Wildermuth,et al.  Accuracy of MSCT coronary angiography with 64-slice technology: first experience. , 2005, European heart journal.

[14]  Y. Jang,et al.  The Utility of Multi-detector Row Spiral CT for Detection of Coronary Artery Stenoses , 2005, Yonsei medical journal.

[15]  S. Shim,et al.  Improvement of image quality with beta-blocker premedication on ECG-gated 16-MDCT coronary angiography. , 2005, AJR. American journal of roentgenology.

[16]  Nico Mollet,et al.  Intravenous contrast material administration at 16-detector row helical CT coronary angiography: test bolus versus bolus-tracking technique. , 2004, Radiology.

[17]  M. Reiser,et al.  Multidetector-row computed tomography and magnetic resonance imaging of atherosclerotic lesions in human ex vivo coronary arteries. , 2004, Atherosclerosis.

[18]  Z. Fayad,et al.  Complementary results of computed tomography and magnetic resonance imaging of the heart and coronary arteries: a review and future outlook. , 2003, Cardiology clinics.

[19]  C. White,et al.  Non-invasive intravenous coronary angiography using electron beam tomography and multislice computed tomography , 2003, Heart.

[20]  W. Bautz,et al.  Detection of Coronary Artery Stenoses With Thin-Slice Multi-Detector Row Spiral Computed Tomography and Multiplanar Reconstruction , 2003, Circulation.

[21]  C. Higgins,et al.  Coronary artery stenoses: assessment with contrast-enhanced electron-beam CT and axial reconstructions. , 1998, Radiology.

[22]  M. Bell,et al.  Intravenous electron-beam computed tomographic coronary angiography for segmental analysis of coronary artery stenoses. , 1998, Journal of the American College of Cardiology.

[23]  R. Frye,et al.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. , 1975, Circulation.