Comparison of Residence Time Estimation Methods for Radioimmunotherapy Dosimetry and Treatment Planning—Monte Carlo Simulation Studies

Estimating the residence times in tumor and normal organs is an essential part of treatment planning for radioimmunotherapy (RIT). This estimation is usually done using a conjugate view whole body scan time series and planar processing. This method has logistical and cost advantages compared to 3-D imaging methods such as Single photon emission computed tomography (SPECT), but, because it does not provide information about the 3-D distribution of activity, it is difficult to fully compensate for effects such as attenuation and background and overlapping activity. Incomplete compensation for these effects reduces the accuracy of the residence time estimates. In this work we compare residence times estimates obtained using planar methods to those from methods based on quantitative SPECT (QSPECT) reconstructions. We have previously developed QSPECT methods that provide compensation for attenuation, scatter, collimator-detector response, and partial volume effects. In this study we compared the use of residence time estimation methods using QSPECT to planar methods. The evaluation was done using the realistic NCAT phantom with organ time activities that model 111In ibritumomab tiuxetan. Projection data were obtained using Monte Carlo simulations (MCS) that realistically model the image formation process including penetration and scatter in the collimator-detector system. These projection data were used to evaluate the accuracy of residence time estimation using a time series of QSPECT studies, a single QSPECT study combined with planar scans and the planar scans alone. The errors in the residence time estimates were 3.8%, 15%, and 2%-107% for the QSPECT, hybrid planar/QSPECT, and planar methods, respectively. The quantitative accuracy was worst for pure planar processing and best for pure QSPECT processing. Hybrid planar/QSPECT methods, where a single QSPECT study was combined with a series of planar scans, provided a large and statistically significant improvement in quantitative accuracy for most organs compared to the planar scans alone, even without sophisticated attention to background subtraction or thickness corrections in planar processing. These results indicate that hybrid planar/QSPECT methods are generally superior to pure planar methods and may be an acceptable alternative to performing a time series of QSPECT studies.

[1]  K K Matthay,et al.  Correlation of tumor and whole-body dosimetry with tumor response and toxicity in refractory neuroblastoma treated with (131)I-MIBG. , 2001, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  K. Ogawa,et al.  A practical method for position-dependent Compton-scatter correction in single photon emission CT. , 1991, IEEE transactions on medical imaging.

[3]  J G Kereiakes,et al.  In vivo quantitation of lesion radioactivity using external counting methods. , 1976, Medical physics.

[4]  William Paul Segars,et al.  Development of a new dynamic NURBS-based cardiac-torso (NCAT) phantom , 2001 .

[5]  Xiaowei Liu,et al.  3D absorbed dose calculations based on SPECT: evaluation for 111-In/90-Y therapy using Monte Carlo simulations. , 2003, Cancer biotherapy & radiopharmaceuticals.

[6]  Thomas F. Budinger,et al.  MIRD primer for absorbed dose calculations , 1988 .

[7]  B.H. Hasegawa,et al.  Use of X-ray CT-defined regions of interest for the determination of SPECT recovery coefficients , 1996, 1996 IEEE Nuclear Science Symposium. Conference Record.

[8]  R. K. Wu,et al.  Absolute quantitation of radioactivity using the buildup factor. , 1984, Medical physics.

[9]  E C Frey,et al.  Fast implementations of reconstruction-based scatter compensation in fully 3D SPECT image reconstruction. , 1998, Physics in medicine and biology.

[10]  K F Koral,et al.  Characterization of scatter and penetration using Monte Carlo simulation in 131I imaging. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  R L Wahl,et al.  Initial results for Hybrid SPECT--conjugate-view tumor dosimetry in 131I-anti-B1 antibody therapy of previously untreated patients with lymphoma. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[12]  Yuni K. Dewaraja,et al.  I-131 SPECT activity recovery coefficients with implicit or triple-energy-window scatter correction , 1999 .

[13]  R L Wahl,et al.  CT-SPECT fusion plus conjugate views for determining dosimetry in iodine-131-monoclonal antibody therapy of lymphoma patients. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[14]  P. N. Badenhorst,et al.  Quantification of the distribution of 111In-labelled platelets in organs , 2004, European Journal of Nuclear Medicine.

[15]  H. Malcolm Hudson,et al.  Accelerated image reconstruction using ordered subsets of projection data , 1994, IEEE Trans. Medical Imaging.

[16]  Michael Ljungberg,et al.  An activity quantification method based on registration of CT and whole-body scintillation camera images, with application to 131I. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[17]  J G Kereiakes,et al.  Quantitative external counting techniques enabling improved diagnostic and therapeutic decisions in patients with well-differentiated thyroid cancer. , 1977, Radiology.

[18]  Michael G Stabin,et al.  OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  A.J. Da Silva,et al.  Implementation of a combined X-ray CT-scintillation camera imaging system for localizing and measuring radionuclide uptake: experiments in phantoms and patients , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[20]  Wen-Tung Wang,et al.  Parameterization of Pb X-ray contamination in simultaneous Tl-201 and Tc-99m dual-isotope imaging , 1999 .

[21]  Yuni Dewaraja,et al.  Update on hybrid conjugate-view SPECT tumor dosimetry and response in 131I-tositumomab therapy of previously untreated lymphoma patients. , 2003, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[22]  G T Chen,et al.  An overview of imaging techniques and physical aspects of treatment planning in radioimmunotherapy. , 1993, Medical physics.

[23]  H R Tang,et al.  Neuroblastoma imaging using a combined CT scanner-scintillation camera and 131I-MIBG. , 2001, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[24]  K F Koral,et al.  Accuracy of 131I tumor quantification in radioimmunotherapy using SPECT imaging with an ultra-high-energy collimator: Monte Carlo study. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[25]  Xiaowei Liu,et al.  A 3-dimensional absorbed dose calculation method based on quantitative SPECT for radionuclide therapy: evaluation for (131)I using monte carlo simulation. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[26]  Eric C. Frey,et al.  Combination of MCNP and SimSET for Monte Carlo Simulation of SPECT with Medium and High Energy Photons , 2001 .

[27]  Kenneth H. Wong,et al.  Calculation and validation of the use of effective attenuation coefficient for attenuation correction in In-111 SPECT. , 2005, Medical physics.

[28]  B. Wessels,et al.  MIRD pamphlet no. 16: Techniques for quantitative radiopharmaceutical biodistribution data acquisition and analysis for use in human radiation dose estimates. , 1999, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[29]  B. Tsui,et al.  A new method for modeling the spatially-variant, object-dependent scatter response function in SPECT , 1996, 1996 IEEE Nuclear Science Symposium. Conference Record.

[30]  Yong Du,et al.  Partial volume effect compensation for quantitative brain SPECT imaging , 2005, IEEE Transactions on Medical Imaging.

[31]  Eric C Frey,et al.  A Monte Carlo and physical phantom evaluation of quantitative In-111 SPECT , 2005, Physics in medicine and biology.

[32]  W P Segars,et al.  Fast modelling of the collimator–detector response in Monte Carlo simulation of SPECT imaging using the angular response function , 2005, Physics in medicine and biology.

[33]  C. Mulhern,et al.  External imaging techniques for quantitation of distribution of I-131 F(ab')2 fragments of monoclonal antibody in humans. , 1984, Medical physics.

[34]  E C Frey,et al.  The importance and implementation of accurate 3D compensation methods for quantitative SPECT. , 1994, Physics in medicine and biology.

[35]  Yuni K. Dewaraja,et al.  Monte Carlo evaluation of object shape effects in iodine-131 SPET tumor activity quantification , 2001, European Journal of Nuclear Medicine.

[36]  R. Jaszczak,et al.  Improved SPECT quantification using compensation for scattered photons. , 1984, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.