Tensile stress-strain characteristics of the human meniscal material.

The nonlinear stress-strain characteristics of the human menisci were determined by uniaxial elongation tests performed on circumferential and radial specimens prepared from different regions, layers, and locations. The properties of the collagen fibers and the matrix were calculated using the test results along with the values of the volume fractions of the meniscal components. Regression analysis showed that only three parameters, the elastic modulus, the maximum strain, and the strain intersect, are sufficient to define the nonlinear stress-strain relation up to failure. For radial specimens, the layer had a significant effect (p < 0.01) on the elastic modulus and the maximum strain, but had no effect on the strain intersect and the maximum stress. For the same specimens, the region had a significant effect (p < 0.01) only on the strain intersect and the maximum stress. For circumferential specimens, analysis indicated no significant effect of either the region, the layer, or the location of the specimens on the material parameters defining the stress-strain relation.

[1]  B B Seedhom,et al.  Transmission of the Load in the Knee Joint with Special Reference to the Role of the Menisci Part I: Anatomy, Analysis and Apparatus , 1979 .

[2]  K. Markolf,et al.  The role of the meniscus in the anterior-posterior stability of the loaded anterior cruciate-deficient knee. Effects of partial versus total excision. , 1986, The Journal of bone and joint surgery. American volume.

[3]  H. Appel,et al.  Late results after meniscectomy in the knee joint. A clinical and roentgenologic follow-up investigation. , 1970, Acta orthopaedica Scandinavica. Supplementum.

[4]  T. Brown,et al.  In vitro contact stress distribution on the femoral condyles , 1984, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[5]  T. Fairbank Knee joint changes after meniscectomy. , 1948, The Journal of bone and joint surgery. British volume.

[6]  J B Finlay,et al.  The effect of medial meniscectomy on strain distribution in the proximal part of the tibia. , 1984, The Journal of bone and joint surgery. American volume.

[7]  V. Mow,et al.  Biphasic creep and stress relaxation of articular cartilage in compression? Theory and experiments. , 1980, Journal of biomechanical engineering.

[8]  A.A.H.J. Sauren,et al.  An Axisymmetric Finite Element Analysis of the Mechanical Function of the Meniscus , 1984 .

[9]  M. Sato [Mechanical properties of living tissues]. , 1986, Iyo denshi to seitai kogaku. Japanese journal of medical electronics and biological engineering.

[10]  Smillie Is The current pattern of internal derangements of the knee joint relative to the menisci. , 1967 .

[11]  P. Walker,et al.  The role of the menisci in force transmission across the knee. , 1975, Clinical orthopaedics and related research.

[12]  J. Galante Tensile properties of the human lumbar annulus fibrosus. , 1967, Acta orthopaedica Scandinavica.

[13]  B B Seedhom,et al.  Transmission of the Load in the Knee Joint with Special Reference to the Role of the Menisci: Part II: Experimental Results, Discussion and Conclusions , 1979 .

[14]  P Ghosh,et al.  The knee joint meniscus , 1987 .

[15]  C. McDevitt,et al.  The ultrastructure and biochemistry of meniscal cartilage. , 1990, Clinical orthopaedics and related research.

[16]  R. Warren,et al.  The effect of medial meniscectomy on anterior-posterior motion of the knee. , 1982, The Journal of bone and joint surgery. American volume.

[17]  P. Walker,et al.  Stabilizing mechanisms of the loaded and unloaded knee joint. , 1976, The Journal of bone and joint surgery. American volume.

[18]  P. Bullough,et al.  The strength of the menisci of the knee as it relates to their fine structure. , 1970, The Journal of bone and joint surgery. British volume.

[19]  A. M. Ahmed,et al.  In-vitro measurement of static pressure distribution in synovial joints--Part I: Tibial surface of the knee. , 1983, Journal of biomechanical engineering.

[20]  J R Moreland,et al.  In vivo stability testing of post-meniscectomy knees. , 1980, Clinical orthopaedics and related research.

[21]  I. Macnab,et al.  The structure of the meniscus of the human knee joint. , 1972, Clinical Orthopaedics and Related Research.

[22]  Y. Fung,et al.  Biology of Collagen , 1980 .

[23]  P S Walker,et al.  Rotatory laxity of the human knee joint. , 1974, The Journal of bone and joint surgery. American volume.

[24]  R. Aspden,et al.  Collagen orientations in the meniscus of the knee joint. , 1985, Journal of anatomy.

[25]  K. Matsushige,et al.  The viscoelastic properties of the human semilunar cartilage. , 1979, Journal of biomechanics.

[26]  Y. Fung,et al.  Biomechanics: Mechanical Properties of Living Tissues , 1981 .

[27]  R M Aspden,et al.  A model for the function and failure of the meniscus. , 1985, Engineering in medicine.

[28]  Peters Tj,et al.  Studies on the chemical composition of the menisci of the knee joint with special reference to the horizontal cleavage lesion. , 1972 .

[29]  A. Beaupré,et al.  Knee Menisci: Correlation Between Microstructure and Biomechanics , 1986, Clinical orthopaedics and related research.

[30]  K. Markolf,et al.  The role of joint load in knee stability. , 1981, The Journal of bone and joint surgery. American volume.

[31]  V C Mow,et al.  A transversely isotropic biphasic finite element model of the meniscus. , 1992, Journal of biomechanics.

[32]  T. Fukubayashi,et al.  Load-bearing mode of the knee joint: physical behavior of the knee joint with or without menisci. , 1980, Clinical orthopaedics and related research.

[33]  A Huson,et al.  A Numerical Model of the Load Transmission in the Tibio-Femoral Contact Area , 1990, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[34]  T. Taylor,et al.  The knee joint meniscus. A fibrocartilage of some distinction. , 1987, Clinical orthopaedics and related research.

[35]  T. Fukubayashi,et al.  The contact area and pressure distribution pattern of the knee. A study of normal and osteoarthrotic knee joints. , 1980, Acta orthopaedica Scandinavica.

[36]  V C Mow,et al.  Material properties and structure-function relationships in the menisci. , 1990, Clinical orthopaedics and related research.

[37]  N. Shrive,et al.  Load-bearing in the knee joint. , 1978, Clinical orthopaedics and related research.