Direct Charged-Particle Imaging System Using an Ultra-Thin Phosphor: Physical Characterization and Dynamic Applications

Imaging beta rays in vivo will help to advance microdosimetry and radiopharmaceutical development. In an earlier paper , we reported a newly developed system capable of directly imaging high-energy electron emissions in small animals in vivo. In this paper, we have thoroughly characterized the performance of the system. We have measured the sensitivity and detectability and the spatial resolution at various magnifications, as well as the linearity of the system. The system has also demonstrated the capability of directly detecting conversion electrons and positrons as well as beta rays. The system has been applied to dynamically image spatiotemporal 18F-Fluorodeoxyglucose (FDG) uptake distributions in xenograft small tumors in dorsal window chambers on mice in vivo. Heterogeneity in FDG uptake in millimeter-sized tumors has been observed.

[1]  Harrison H Barrett,et al.  Direct Imaging of Radionuclide-Produced Electrons and Positrons with an Ultrathin Phosphor , 2008, Journal of Nuclear Medicine.

[2]  Satomi Kanno,et al.  Real-time imaging of radioisotope labeled compounds in a living plant , 2007 .

[3]  Detection of Beta Particles in a Microfluidic Chip Using a Scintillator and CCD , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[4]  Gerald Entine,et al.  Feasibility studies of an EMCCD-based beta imaging probe for radioguided thyroid surgery , 2006, SPIE Optics + Photonics.

[5]  Harrison H. Barrett,et al.  Foundations of Image Science , 2003, J. Electronic Imaging.

[6]  T. Tanimori,et al.  Development of μ-PIC and its imaging properties , 2004 .

[7]  M. C. Montesi,et al.  Tritium digital autoradiography with a Medipix2 hybrid silicon pixel detector , 2004 .

[8]  Ray Bell,et al.  A 512 512 CMOS Monolithic Active Pixel Sensor with integrated ADCs for space science , 2003 .

[9]  G. Charpak,et al.  Micromegas, a multipurpose gaseous detector , 2002 .

[10]  K Wells,et al.  The performance of a CCD digital autoradiography imaging system. , 2000, Physics in medicine and biology.

[11]  Siqing Shan,et al.  Noninvasive visualization of tumors in rodent dorsal skin window chambers , 1999, Nature Biotechnology.

[12]  T. Gys,et al.  An ISPA camera for beta radiography , 1996 .

[13]  Kaj Ljunggren,et al.  Reduction of noise in the Beta camera for low activity applications , 1994 .

[14]  Y. Charon,et al.  HRRI: a high resolution radioimager for fast, direct quantification in in situ hybridization experiments. , 1994, BioTechniques.

[15]  A. Karellas,et al.  Imaging of radionuclide emissions with a low-noise charge-coupled device , 1992, IEEE Conference on Nuclear Science Symposium and Medical Imaging.

[16]  B. Sanghera,et al.  Preliminary studies using silicon strip detectors in digital autoradiography , 1992, IEEE Conference on Nuclear Science Symposium and Medical Imaging.

[17]  C. Eijk,et al.  An MWPC for beta radiochromatography , 1988 .

[18]  J. Gross,et al.  A transparent access chamber for the rat dorsal skin fold. , 1979, Microvascular research.

[19]  V. Peshekhonov,et al.  Use of a proportional chamber for quantitative and qualitative analysis of thin-layer radiochromatograms , 1978 .

[20]  R. K. Swank Absorption and noise in x‐ray phosphors , 1973 .

[21]  R. E. Burgess,et al.  Homophase and heterophase fluctuations in semiconducting crystals , 1959 .