Registration of a Statistical Shape Model of the Lumbar Spine to 3D Ultrasound Images

MOTIVATION Spinal needle injections are technically demanding procedures. The use of ultrasound image guidance without prior CT and MR imagery promises to improve the efficacy and safety of these procedures in an affordable manner. METHODOLOGY We propose to create a statistical shape model of the lumbar spine and warp this atlas to patient-specific ultrasound images during the needle placement procedure. From CT image volumes of 35 patients, statistical shape model of the L3 vertebra is built, including mean shape and main modes of variation. This shape model is registered to the ultrasound data by simultaneously optimizing the parameters of the model and its relative pose. Ground-truth data was established by printing 3D anatomical models of 3 patients using a rapid prototyping. CT and ultrasound data of these models were registered using fiducial markers. RESULTS Pairwise registration of the statistical shape model and 3D ultrasound images led to a mean target registration error of 3.4 mm, while 81% of all cases yielded clinically acceptable accuracy below the 3.5 mm threshold.

[1]  Stuart Crozier,et al.  Atlas based automated segmentation of the quadratus lumborum muscle using non-rigid registration on magnetic resonance images of the thoracolumbar region , 2008, 2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[2]  M J Watson,et al.  Could ultrasonography be used by an anaesthetist to identify a specified lumbar interspace before spinal anaesthesia? , 2003, British journal of anaesthesia.

[3]  Watts Rw,et al.  A five-year prospective analysis of the efficacy, safety and morbidity of epidural anaesthesia performed by a general practitioner anaesthetist in an isolated rural hospital. , 1992 .

[4]  Guido Gerig,et al.  Medical Image Computing and Computer-Assisted Intervention - MICCAI 2005, 8th International Conference, Palm Springs, CA, USA, October 26-29, 2005, Proceedings, Part II , 2005, MICCAI.

[5]  David J. Hawkes,et al.  MR to Ultrasound Image Registration for Guiding Prostate Biopsy and Interventions , 2009, MICCAI.

[6]  Sean Sullivan,et al.  The Burden of Pain on Employee Health and Productivity at a Major Provider of Business Services , 2005, Journal of occupational and environmental medicine.

[7]  Russell H. Taylor,et al.  Rendering tetrahedral meshes with higher-order attenuation functions for digital radiograph reconstruction , 2005, VIS 05. IEEE Visualization, 2005..

[8]  Martin Styner,et al.  A comparison study assessing the feasibility of ultrasound-initialized deformable bone models , 2005 .

[9]  Nassir Navab,et al.  Automatic CT-ultrasound registration for diagnostic imaging and image-guided intervention , 2008, Medical Image Anal..

[10]  David J. Hawkes,et al.  Instantiation and registration of statistical shape models of the femur and pelvis using 3D ultrasound imaging , 2008, Medical Image Anal..

[11]  Kirsten Schmieder,et al.  Registration of CT and Intraoperative 3-D Ultrasound Images of the Spine Using Evolutionary and Gradient-Based Methods , 2008, IEEE Transactions on Evolutionary Computation.

[12]  Petros Koumoutsakos,et al.  Reducing the Time Complexity of the Derandomized Evolution Strategy with Covariance Matrix Adaptation (CMA-ES) , 2003, Evolutionary Computation.

[13]  Nicholas Ayache,et al.  Geometric Variability of the Scoliotic Spine Using Statistics on Articulated Shape Models , 2008, IEEE Transactions on Medical Imaging.

[14]  Lena Costaridou,et al.  Atlas-Based Segmentation of Degenerated Lumbar Intervertebral Discs From MR Images of the Spine , 2009, IEEE Transactions on Biomedical Engineering.

[15]  Russell H. Taylor,et al.  Localization of Pelvic Anatomical Coordinate System Using US/Atlas Registration for Total Hip Replacement , 2008, MICCAI.

[16]  Terry M. Peters,et al.  Image Guidance for Spinal Facet Injections Using Tracked Ultrasound , 2009, MICCAI.

[17]  T. Jenkinson,et al.  Sonographically Guided Caudal Epidural Steroid Injections , 2003, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[18]  Randy E. Ellis,et al.  2D/3D Deformable Registration Using a Hybrid Atlas , 2005, MICCAI.

[19]  Christopher J. Taylor,et al.  Medical Image Computing and Computer-Assisted Intervention – MICCAI 2009 , 2009, Lecture Notes in Computer Science.

[20]  Gabor Fichtinger,et al.  Medical Image Computing and Computer-Assisted Intervention - MICCAI 2008, 11th International Conference, New York, NY, USA, September 6-10, 2008, Proceedings, Part I , 2008, International Conference on Medical Image Computing and Computer-Assisted Intervention.

[21]  A. James Stewart,et al.  Reduction of multi-fragment fractures of the distal radius using atlas-based 2D/3D registration , 2009, Medical Imaging.

[22]  Gabor Fichtinger,et al.  Biomechanically Constrained Groupwise US to CT Registration of the Lumbar Spine , 2009, MICCAI.

[23]  Purang Abolmaesumi,et al.  A real-time freehand ultrasound calibration system with automatic accuracy feedback and control. , 2009, Ultrasound in medicine & biology.