Data Processing Methods for a High Throughput Brain Imaging PET Research Center

We describe a computer system designed to meet the data processing needs of a high-volume brain PET research center based on the High Resolution Research Tomograph (HRRT). Listmode data are collected by an acquisition computer and stored on a high-speed disk. A workflow management program transfers the data through a gigabit network, rebins events into sinograms, and calculates correction factors. Reconstruction jobs are performed on a 64 processor cluster. We developed methods for dynamically allocating subclusters from the pool of available nodes, and reconstructing multiple images on multiple subclusters simultaneously. We also studied overall workflow. In our initial plan, scatter and randoms calculation unexpectedly became a bottleneck. We therefore adjusted our plan so that scatter estimation was performed initially in low resolution, and later expanded to high resolution.

[1]  H.W.A.M. de Jong,et al.  Simultaneous measurement of transmission and emission contamination using a collimated /sup 137/Cs point source for the HRRT , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[2]  D. Wong In vivo imaging of D2 dopamine receptors in schizophrenia: the ups and downs of neuroimaging research. , 2002, Archives of general psychiatry.

[3]  Andrew J. Reader,et al.  EM algorithm system modeling by image-space techniques for PET reconstruction , 2003 .

[4]  C. C. Watson,et al.  New, faster, image-based scatter correction for 3D PET , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[5]  Jeih-San Liow,et al.  Variance Reduction on Randoms from delayed coincidence histograms for the HRRT , 2005 .

[6]  Dean F. Wong,et al.  Sex Differences in Striatal Dopamine Release in Healthy Adults , 2006, Biological Psychiatry.

[7]  Xuan Liu,et al.  Comparison of 3-D reconstruction with 3D-OSEM and with FORE+OSEM for PET , 2001, IEEE Transactions on Medical Imaging.

[8]  David W. Townsend,et al.  Positron Emission Tomography , 1985, Other Conferences.

[9]  M. Pomper,et al.  Predicting the success of a radiopharmaceutical for in vivo imaging of central nervous system neuroreceptor systems. , 2003 .

[10]  I.K. Hong,et al.  Fast forward projection and backward projection algorithm using SIMD , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[11]  Monique Ernst,et al.  Increased Occupancy of Dopamine Receptors in Human Striatum during Cue-Elicited Cocaine Craving , 2007, Neuropsychopharmacology.

[12]  C. Comtat,et al.  OSEM-3D reconstruction strategies for the ECAT HRRT , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[13]  Jeih-San Liow,et al.  Variance reduction on randoms from coincidence histograms for the HRRT , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[14]  Jeih-San Liow,et al.  Count-Rate Dependent Component-Based Normalization for the HRRT , 2007, IEEE Transactions on Nuclear Science.

[15]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[16]  Klaus Wienhard,et al.  The ECAT HRRT: performance and first clinical application of the new high resolution research tomograph , 2000 .

[17]  C. Comtat,et al.  Improved Clinical Parametric Imaging Using List-Mode Reconstruction via Resolution Modeling , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[18]  Z. Burbar,et al.  Clinical time OSEM3D: infrastructure issues , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[19]  James Robert Brašić,et al.  PROOF OF CONCEPT: FUNCTIONAL MODELS FOR DRUG DEVELOPMENT IN HUMANS , 2002 .

[20]  Patrick Dupont,et al.  Evaluation of maximum-likelihood based attenuation correction in positron emission tomography , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[21]  G. Muehllehner,et al.  Positron emission tomography , 2006, Physics in medicine and biology.

[22]  M. Casey,et al.  SPMD cluster-based parallel 3D OSEM , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[23]  D. Wong,et al.  Mechanism of new antipsychotic medications: occupancy is not just antagonism. , 2003, Archives of general psychiatry.