Active Microfluidic Micromixer Design using Ionic Polymer-Metal Composites

In most of the microfluidic applications, it is necessary to have a mixed fluid from the beginning, but in microchannels, due to facing with low Reynolds flows, the fluids flow in the channel by the laminar regimes. Hence the mixing process is a challenging problem and researchers are trying to present fast and reliable micromixers. In this paper, using Ionic Polymer-Metal Composites (IPMCs), an active micromixer has been designed. To investigate the appropriateness of IPMC, using experimental and simulation tests, we show that the IPMC actuator is a potential candidate as an active element of microfluidic micromixers.

[1]  Reza Montazami,et al.  Ionic electroactive polymer actuators as active microfluidic mixers , 2015 .

[2]  Kean C. Aw,et al.  A Compact Ionic Polymer-Metal Composite (IPMC) Actuated Valveless Pump for Drug Delivery , 2017, IEEE/ASME Transactions on Mechatronics.

[3]  N. Naghavi,et al.  Non-uniform deformation and curvature identification of ionic polymer metal composite actuators , 2015 .

[4]  Hyung-Kun Lee,et al.  Microvalves based on ionic polymer-metal composites for microfluidic application. , 2011, Journal of nanoscience and nanotechnology.

[5]  Nam-Trung Nguyen,et al.  Micromixers?a review , 2005 .

[6]  J. J. Huang,et al.  An electro-thermal micro mixer , 2011, 2011 6th IEEE International Conference on Nano/Micro Engineered and Molecular Systems.

[7]  Utkan Demirci,et al.  Guidance and Self‐Sorting of Active Swimmers: 3D Periodic Arrays Increase Persistence Length of Human Sperm Selecting for the Fittest , 2017, Advanced science.

[8]  Nadia Naghavi,et al.  Nonautoregressive Nonlinear Identification of IPMC in Large Deformation Situations Using Generalized Volterra-Based Approach , 2016, IEEE Transactions on Instrumentation and Measurement.

[9]  Alicia M. Williams,et al.  Laminar mixing using oscillating cantilevered ionic polymer actuators , 2009 .

[10]  S. Bhattacharjee,et al.  Study on the use of dielectrophoresis and electrothermal forces to produce on-chip micromixers and microconcentrators. , 2012, Biomicrofluidics.

[11]  P. Sajeesh,et al.  Particle separation and sorting in microfluidic devices: a review , 2014 .

[12]  Takuma Kobayashi,et al.  Ionic Polymer Metal Composite (IPMC) for MEMS Actuator and Sensor , 2011 .

[13]  Roland Zengerle,et al.  Active Continuous-Flow Micromixer Using an External Braille Pin Actuator Array , 2013, Micromachines.

[14]  Teruo Fujii,et al.  A plug and play microfluidic device. , 2003, Lab on a chip.

[15]  Y. Bar-Cohen,et al.  Ionic Polymer-MetalComposites ( IPMC ) As Biomimetic Sensors , Actuators & Artificial Muscles-A , 2022 .

[16]  Guo-Hua Feng,et al.  Micromachined optical fiber enclosed 4-electrode IPMC actuator with multidirectional control ability for biomedical application , 2011, Biomedical microdevices.

[17]  E. Lesniewska,et al.  Design and Fabrication of an Acoustic Micromixer for Biological Media Activation , 2014 .

[18]  M. A. Stott,et al.  Optofluidic detection of Zika nucleic acid and protein biomarkers using multimode interference multiplexing. , 2018, Biomedical optics express.

[19]  Nadine Aubry,et al.  Electro-hydrodynamic micro-fluidic mixer. , 2003, Lab on a chip.

[20]  Zachary R. Gagnon,et al.  Cellular dielectrophoresis: Applications to the characterization, manipulation, separation and patterning of cells , 2011, Electrophoresis.

[21]  Won-jong Kim,et al.  Aquatic Ionic-Polymer-Metal-Composite Insectile Robot With Multi-DOF Legs , 2013, IEEE/ASME Transactions on Mechatronics.

[22]  Ming Lei,et al.  Optical sorting of particles by dual-channel line optical tweezers , 2012 .

[23]  Nadia Naghavi,et al.  From modeling to implementation of a method for restraining back relaxation in ionic polymer–metal composite soft actuators , 2018, Journal of Intelligent Material Systems and Structures.

[24]  Nadia Naghavi,et al.  Nonlinear identification of IPMC actuators based on ANFIS–NARX paradigm , 2014 .

[25]  Zhigang Wu,et al.  Microfluidic electronics. , 2012, Lab on a chip.

[26]  Darwin R. Reyes,et al.  Micro total analysis systems. 1. Introduction, theory, and technology. , 2002, Analytical chemistry.

[27]  H Tom Soh,et al.  Tunable acoustophoretic band-pass particle sorter. , 2010, Applied physics letters.

[28]  Unyoung Kim,et al.  Multitarget magnetic activated cell sorter , 2008, Proceedings of the National Academy of Sciences.

[29]  Keekyoung Kim,et al.  Organ-on-a-Chip Platforms for Drug Screening and Tissue Engineering , 2016 .

[30]  G. Whitesides The origins and the future of microfluidics , 2006, Nature.

[31]  Nadia Naghavi,et al.  Restraining IPMC Back Relaxation in Large Bending Displacements: Applying Non-Feedback Local Gaussian Disturbance by Patterned Electrodes , 2016, IEEE Transactions on Electron Devices.

[32]  Cheng-Hsien Liu,et al.  A novel electrokinetic micromixer , 2003, TRANSDUCERS '03. 12th International Conference on Solid-State Sensors, Actuators and Microsystems. Digest of Technical Papers (Cat. No.03TH8664).

[33]  Manoj Kumar Kanakasabapathy,et al.  An automated smartphone-based diagnostic assay for point-of-care semen analysis , 2017, Science Translational Medicine.

[34]  Mohammad Passandideh-Fard,et al.  Rapid mixing in micromixers using magnetic field , 2017 .