Damage assessment and the effectiveness of prevention: the response of ordinary unreinforced masonry buildings in Norcia during the Central Italy 2016–2017 seismic sequence

Four regions of central Italy were struck by the seismic sequence of the 2016 earthquake in the country: Lazio, Abruzzo, Umbria and Marche. This highlighted the different behaviour of masonry constructions depending on the prevention actions carried out after previous earthquakes. In particular, although damaged, the masonry buildings in the historical centre of Norcia (Umbria region) behaved significantly better than those in other regions. Indeed, the strengthening interventions carried out after the earthquakes of 1971, 1979 and 1997 greatly affected the seismic behaviour of masonry aggregates (contiguous masonry structural units, MSUs) in the historical centre, which sustained limited damage and a low number of collapses. This paper discusses the empirical data on damage collected with respect to 670 MSUs by means of the first level survey form concerning post-earthquake damage, and usability assessments (AeDES). The forms completed for the survey relate to MSUs in the historical centre of Norcia and were produced by the technicians of the Umbria Seismic Risk Office. The analysis shows the correlation between the MSU characteristics of: age of construction and renovation work; type of vertical and horizontal structures; roof types and usability rating; and the damage level and extent thereof detected in vertical structures. The effectiveness of previous strengthening interventions and the analyses of the types of strengthening solution are also discussed. A case study aggregate is analyzed in detail in order to illustrate the importance of strengthening interventions on vertical bearing elements. The strengthening interventions resulted in a sound strategy to strongly reduce losses, even in a very vulnerable centre comprised of old residential masonry aggregates.

[1]  Antonio Borri,et al.  A method for the analysis and classification of historic masonry , 2015, Bulletin of Earthquake Engineering.

[2]  Natalino Gattesco,et al.  Experimental and analytical study to evaluate the effectiveness of an in-plane reinforcement for masonry walls using GFRP meshes , 2015 .

[3]  Serena Cattari,et al.  Seismic behaviour of ordinary masonry buildings during the 2016 central Italy earthquakes , 2019, Bulletin of Earthquake Engineering.

[4]  Andrea Prota,et al.  Seismic Strengthening of Masonry Vaults with Abutments Using Textile-Reinforced Mortar , 2016 .

[5]  Marco Di Ludovico,et al.  Reconstruction process of damaged residential buildings outside historical centres after the L’Aquila earthquake: part I—"light damage" reconstruction , 2017, Bulletin of Earthquake Engineering.

[6]  Luigi Sorrentino,et al.  Simplified survey form of unreinforced masonry buildings calibrated on data from the 2009 L’Aquila earthquake , 2017, Bulletin of Earthquake Engineering.

[7]  Andrea Prota,et al.  Out-of-plane experimental behaviour of T-shaped full scale masonry wall strengthened with composite connections , 2016 .

[8]  M. Locati,et al.  DBMI15, the 2015 version of the Italian Macroseismic Database , 2016 .

[9]  Andrea Prota,et al.  Reconstruction process of damaged residential buildings outside historical centres after the L’Aquila earthquake: part II—“heavy damage” reconstruction , 2016, Bulletin of Earthquake Engineering.

[10]  F. Mollaioli,et al.  Seismic demand of the 2016–2017 Central Italy earthquakes , 2018, Bulletin of Earthquake Engineering.

[11]  A. Prota,et al.  Masonry Walls Strengthened With Innovative Composites , 2011, SP-275: Fiber-Reinforced Polymer Reinforcement for Concrete Structures 10th International Symposium.

[12]  Alberto Bernardini,et al.  Field Manual for post-earthquake damage and safety assessment and short term countermeasures ( AeDES ) , 2007 .

[13]  C. Modena,et al.  Shear behavior of masonry panels strengthened by FRP laminates , 2002 .

[14]  A. Prota,et al.  Analysis of the Population Assistance and Returning Home in the Reconstruction Process of the 2009 L’Aquila Earthquake , 2017 .

[15]  M. Corradi,et al.  An experimental study on the influence of composite materials used to reinforce masonry ring beams , 2016 .

[16]  M. Dolce,et al.  Estimation of repair costs for RC and masonry residential buildings based on damage data collected by post-earthquake visual inspection , 2017, Bulletin of Earthquake Engineering.