Differences in mechanical properties between human and porcine aortic root

Recently, percutaneous aortic valve (PAV) replacement has been investigated as an endovascular alternative for the treatment of aortic stenosis. Percutaneous valve intervention requires a thorough material characterization of the human aortic root and ascending aorta for successful PAV deployment and function. Recent PAV clinical trials have been conducted on animal models under the assumption that animal tissues are closely related to human (1, 2). However, various adverse effects detected after device implantation such as device fracture, myocardial infarction, peripheral embolism, aortic injury, perivalvular leak and access site injury have been reported (3, 4). We hypothesize that the biomechanical interaction between the device and the host tissue plays an important role that determines the efficacy of the PAV treatment. Thus, there is a need obtaining the mechanical properties of the host tissues for the future analysis of device-tissue interaction. In this study, we characterized the mechanical properties of aged human aortic tissues and compared them to porcine tissues to determine whether animal studies are appropriate for the PAV trials. Our results suggest there are significant differences between porcine and human aortic tissues and the efficacy of animal models for PAV simulation should be further investigated.

[1]  P. Brown,et al.  Chemoprevention of breast cancer , 2000, Breast Cancer Research and Treatment.

[2]  Natesa G Pandian,et al.  Percutaneous mitral valve repair: A feasibility study in an ovine model of acute ischemic mitral regurgitation , 2003, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[3]  Lukas Altwegg,et al.  Percutaneous Transarterial Aortic Valve Replacement in Selected High-Risk Patients With Aortic Stenosis , 2007, Circulation.

[4]  G. Vunjak‐Novakovic,et al.  Cartilage-like tissue engineering using silk scaffolds and mesenchymal stem cells. , 2006, Tissue engineering.

[5]  Wei Sun,et al.  Multiaxial mechanical behavior of biological materials. , 2003, Annual review of biomedical engineering.

[6]  G. Vunjak‐Novakovic,et al.  Stem cell-based tissue engineering with silk biomaterials. , 2006, Biomaterials.

[7]  L. Afonso,et al.  Calcific aortic valve and spontaneous embolic stroke: A review of literature , 2009, Journal of the Neurological Sciences.

[8]  Thomas Felderhoff,et al.  Percutaneous Implantation of the CoreValve Self-Expanding Valve Prosthesis in High-Risk Patients With Aortic Valve Disease: The Siegburg First-in-Man Study , 2006 .

[9]  David Saloner,et al.  Significant material property differences between the porcine ascending aorta and aortic sinuses. , 2008, The Journal of heart valve disease.

[10]  R. Hickler,et al.  Aortic and large artery stiffness: Current methodology and clinical correlations , 1990, Clinical cardiology.

[11]  C. Mettlin,et al.  Global breast cancer mortality statistics , 1999, CA: a cancer journal for clinicians.