Introduction of electronics into milking technology

Abstract In countries, like the former German Democratic Republic (GDR), where ‘industrialized’ milk production in large herds was the goal to be reached, research on automation of machine milking was started more than 30 years ago. Initially, the main goal was to mechanize operations at the end of the milking process. This work finally resulted in milking devices that do not apply uniform parameters to all cows, but operate according to the milk flow obtained from the cow actually to be milked. This evolution towards ‘controlled milking’ would not have been possible without application of electricity and electronic components for sensors and control units. Also depending on the technical evolution of electronic control systems are devices for recording milk yield and for taking samples for milk analysis, which were available around the year 1980. At that time initial projects for automatic milk recording were evaluated, which had an obvious influence on further development of milk meters. The most demanding step of application of electronic control systems up to now was the introduction of automatic milking systems. Here not only application of teat cups has to be executed, it also is necessary to enable automatic checks of udder condition, milk quality and other operations which may be challenging even for trained human operators. Further evolution of electronic measurement procedures may be important for the milk-producing farmer too, especially when on-line milk analysis is to be introduced within the near future.

[1]  T. Mottram,et al.  Optical teat inspection for automatic milking systems , 1995 .

[2]  Schalm Ow,et al.  Experiments and observations leading to development of the California mastitis test. , 1957 .

[3]  C. A. Kiddy,et al.  Variation in physical activity as an indication of estrus in dairy cows. , 1977, Journal of dairy science.

[4]  S. L. Spahr,et al.  Expert Systems—Their Use in Dairy Herd Management , 1988 .

[5]  D. Ordolff A System for Automatic Teat-cup Attachment , 1984 .

[6]  D. O. Noorlander,et al.  Experiments and observations leading to development of the California mastitis test. , 1957, Journal of the American Veterinary Medical Association.

[7]  Rudolf Artmann,et al.  Entwicklungsstand von Melkrobotern , 1990 .

[8]  E. J. Cant,et al.  Measurement of milk temperature as an aid to oestrus detection in dairy cattle , 1978, The Journal of Agricultural Science.

[9]  T S Gross,et al.  Comparison of estrus detection techniques in dairy heifers. , 1981, Journal of dairy science.

[10]  M. Peaker,et al.  Efficacy of the measurement of the electrical conductivity of milk for the detection of subclinical mastitis in cows: detection of infected cows at a single visit. , 1975, The British veterinary journal.

[11]  W. Paul,et al.  Die Messung der Milchtemperatur als Mittel zur Überwachung der Tiergesundheit und zur Steuerung des Milchentzuges , 1979 .

[12]  Michael John Street,et al.  A pneumatic milking robot - structure, performance and first results. , 1990 .

[13]  R. A. Pellerin,et al.  Adjustable speed drive - two vacuum milking system. , 1990 .

[14]  N. R. Scott,et al.  Electrical Conductivity Probes for Detection of Estrus in Cattle , 1979 .

[15]  D. Ordolff,et al.  Experiments on automatic preparation of milk samples in connection with milking robots , 1997 .

[16]  N. R. Scott,et al.  Pregnancy rate in dairy cows inseminated on the basis of electronic probe measurements. , 1979, Journal of dairy science.

[17]  N. R. Scott,et al.  Estrous cycle patterns in cattle monitored by electrical resistance and milk progesterone. , 1979, Journal of dairy science.