Universal Standardization of Forearm Bone Densitometry

As part of an effort to quantify device‐dependent differences in forearm bone density, 101 women, aged 20‐80 years (∼16 women in each age decade), were scanned on six forearm bone densitometers: the Aloka DCS‐600EX, the Hologic QDR‐4500A, the Lunar PIXI, the Norland pDEXA, the Osteometer DTX‐200, and the Pronosco X‐posure System. Regression statistics are reported for all similar regions of interest (ROIs). However, comparisons were confounded because of large differences in the ROI size and placement. The number of ROIs reported for a single scan by each device varied from 1 to 12. The correlation coefficients ranged from 0.7 < r < 0.97, with the highest correlation coefficients and lowest SEs for comparisons between the most similar ROIs. Standardized units of bone mineral density are derived for distal (sdBMD), mid‐ (smBMD), and proximal (spBMD) ROIs that allow for comparable mean bone densities to be derived for patient populations. Five phantoms were scanned and characterized on five of the devices and the precision and mean values were reported. These phantom values will aid in the in vitro cross‐calibration between manufacturers to recreate the presented in vivo relationships. Care should be exercised when using these equations for cross‐calibrating patient databases or pooling clinical data from different devices because the least significant differences detectable from measurements taken on two different machines can be increased substantially.

[1]  J. Hanson Standardization of proximal femur BMD measurements. International Committee for Standards in Bone Measurement. , 1997, Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA.

[2]  H. Wahner,et al.  Updated Data on Proximal Femur Bone Mineral Levels of US Adults , 1998, Osteoporosis International.

[3]  P. Steiger Standardization of measurements for assessing BMD by DXA , 1995, Calcified Tissue International.

[4]  H. K. Genant,et al.  Standardization of Bone Mineral Density at Femoral Neck, Trochanter and Ward’s Triangle , 2001, Osteoporosis International.

[5]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[6]  S. Cummings,et al.  Classification of Osteoporosis Based on Bone Mineral Densities , 2001, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[7]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[8]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[9]  C C Glüer,et al.  Monitoring Skeletal Changes by Radiological Techniques , 1999, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[10]  S L Hui,et al.  Universal Standardization of Bone Density Measurements: A Method with Optimal Properties for Calibration Among Several Instruments , 1997, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[11]  I. Cullum,et al.  Cross-calibration of a fan-beam X-ray densitometer with a pencil-beam system. , 1996, The British journal of radiology.

[12]  O. Johnell,et al.  A Single Bone Density Measurement Can Predict Fractures Over 25 Years , 1997, Calcified Tissue International.

[13]  S. Addelman,et al.  Fitting straight lines when both variables are subject to error. , 1978, Life sciences.

[14]  Klaus Engelke,et al.  Universal standardization for dual X‐ray absorptiometry: Patient and phantom cross‐calibration results , 1994, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[15]  M. McClung,et al.  Densitometry of the radius using single and dual energy absorptiometry , 1994, Calcified Tissue International.

[16]  H. Genant,et al.  Dual X‐ray absorptiometry forearm software: Accuracy and intermachine relationship , 1994, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[17]  C. Christiansen,et al.  Bone composition in the distal forearm. , 1987, Scandinavian journal of clinical and laboratory investigation.

[18]  A. Rossier Letter to the Editor , 1986, Paraplegia.

[19]  Standardization of proximal femur bone mineral density (BMD) measurements by DXA. International Committee for Standards in Bone Measurement. , 1997, Bone.

[20]  C. Christiansen,et al.  Impact of soft tissue on in vivo accuracy of bone mineral measurements in the spine, hip, and forearm: A human cadaver study , 1995, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[21]  Thomas A. Jones,et al.  Fitting straight lines when both variables are subject to error. , 1979 .

[22]  P. Steiger Standardization of postero-anterior (PA) spine BMD measurements by DXA. Committee for Standards in DXA. , 1995, Bone.