The evaluation of a highly automated mixture model based technique for PET tumor volume segmentation

PET-based tumor volume segmentation techniques are under investigation in recent years due to the increased utilization of FDG-PET imaging in radiation therapy. We have taken the approach of using a Gaussian mixture model (GMM) to model the image intensity distribution of a selected 3D region that completely covers the tumor, called the "analysis region". The modeling is performed with a predetermined number of Gaussian classes and results in a classification of every voxel into one of these classes. The classes are then grouped together to obtain the tumor volume. The only user interaction required is the selection of the "analysis region" and then the algorithm proceeds automatically to initialize the parameters of the different classes and finds the maximum likelihood estimate with expectation maximization. We used 13 clinical and 19 phantom cases to evaluate the precision and accuracy of the segmentation. Reproducibility was within 10% of the average tumor volume estimate and accuracy was ±35% of the true tumor volume and better when compared to two other proposed techniques. The GMM segmentation is extremely user friendly with good precision and accuracy. It has shown great potential to be used in the clinical environment.

[1]  Di Yan,et al.  Defining a radiotherapy target with positron emission tomography. , 2002, International journal of radiation oncology, biology, physics.

[2]  P B Hoffer,et al.  Computerized three-dimensional segmented human anatomy. , 1994, Medical physics.

[3]  Curtis B Caldwell,et al.  Can PET provide the 3D extent of tumor motion for individualized internal target volumes? A phantom study of the limitations of CT and the promise of PET. , 2003, International journal of radiation oncology, biology, physics.

[4]  Sasa Mutic,et al.  Impact of FDG-PET on radiation therapy volume delineation in non-small-cell lung cancer. , 2004, International journal of radiation oncology, biology, physics.

[5]  Zhengrong Liang,et al.  Parameter estimation and tissue segmentation from multispectral MR images , 1994, IEEE Trans. Medical Imaging.

[6]  Gábor Székely,et al.  Assessment of 18F PET signals for automatic target volume definition in radiotherapy treatment planning. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[7]  Michalis Aristophanous,et al.  The development and testing of a digital PET phantom for the evaluation of tumor volume segmentation techniques. , 2008, Medical physics.

[8]  Abbes Amira,et al.  Fully automated segmentation of oncological PET volumes using a combined multiscale and statistical model. , 2007, Medical physics.

[9]  B. C. Penney,et al.  A Gaussian mixture model for definition of lung tumor volumes in positron emission tomography. , 2007, Medical physics.

[10]  S M Larson,et al.  Segmentation of lung lesion volume by adaptive positron emission tomography image thresholding , 1997, Cancer.

[11]  C C Ling,et al.  Towards multidimensional radiotherapy (MD-CRT): biological imaging and biological conformality. , 2000, International journal of radiation oncology, biology, physics.

[12]  Gianluca Valentini,et al.  Radiotherapy planning: PET/CT scanner performances in the definition of gross tumour volume and clinical target volume , 2005, European Journal of Nuclear Medicine and Molecular Imaging.

[13]  D R Haynor,et al.  Partial volume tissue classification of multichannel magnetic resonance images-a mixel model. , 1991, IEEE transactions on medical imaging.

[14]  Thomas J. Hebert,et al.  Bayesian pixel classification using spatially variant finite mixtures and the generalized EM algorithm , 1998, IEEE Trans. Image Process..

[15]  C. Rübe,et al.  Comparison of different methods for delineation of 18F-FDG PET-positive tissue for target volume definition in radiotherapy of patients with non-Small cell lung cancer. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[16]  Anne Bol,et al.  Tri-dimensional automatic segmentation of PET volumes based on measured source-to-background ratios: influence of reconstruction algorithms. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.