Circulating type motor bearing current in inverter drives

To facilitate understanding of the differences between the two types of inverter-induced bearing currents which appear in induction motor drives, a review of the previous noncirculating type of bearing current theory is given. A brief introduction to the concept of coupling current in drive systems follows. This article then proposes an explanation to the generation of a circulating-type of bearing current in inverter-fed motor drives. The theory is backed up by the experimental measurement of bearing currents. Finally, a solution to these bearing currents, of both circulating and noncirculating types, is also proposed.

[1]  Doyle F. Busse,et al.  The effects of PWM voltage source inverters on the mechanical performance of rolling bearings , 1997 .

[2]  T. Lipo,et al.  Elimination of common mode voltage in three phase sinusoidal power converters , 1996, PESC Record. 27th Annual IEEE Power Electronics Specialists Conference.

[3]  J. Erdman,et al.  Effect of PWM inverters on AC motor bearing currents and shaft voltages , 1995, Proceedings of 1995 IEEE Applied Power Electronics Conference and Exposition - APEC'95.

[4]  I. Kerszenbaum Shaft currents in electric machines fed by solid-state drives , 1992, 1992 IEEE Conference Record of the Industrial and Commercial Power Systems Technical Conference.

[5]  P. L. Alger,et al.  Shaft currents in electric machines , 1923, Journal of the American Institute of Electrical Engineers.

[6]  Thomas A. Lipo,et al.  Source of induction motor bearing currents caused by PWM inverters , 1996 .