Why epidurals do not always work.

The overwhelming majority of epidural catheters placed for labor provide satisfactory analgesia. There are, however, times when the catheter is not sited within the epidural space correctly, the patient's neuraxial anatomy is problematic, or a patient's labor progresses more quickly than expected by the anesthesiologist, and the epidural block does not set up on time. In this article, the basics of neuraxial labor analgesia, the causes of its failure, and the strategies anesthesiologists employ to rescue poorly functioning catheters are reviewed.

[1]  G. Weinberg Current Concepts in Resuscitation of Patients With Local Anesthetic Cardiac Toxicity , 2002, Regional Anesthesia & Pain Medicine.

[2]  T. Bogard,et al.  Incidence and characteristics of failures in obstetric neuraxial analgesia and anesthesia: a retrospective analysis of 19,259 deliveries. , 2004, International journal of obstetric anesthesia.

[3]  C. Collier Accidental Subdural Injection During Attempted Lumbar Epidural Block May Present as a Failed or Inadequate Block: Radiographic Evidence , 2003, Regional Anesthesia & Pain Medicine.

[4]  I. Parkin,et al.  Resin injection studies of the lumbar extradural space. , 1985, British journal of anaesthesia.

[5]  S. Corman,et al.  Drug Information Rounds: Use of Lipid Emulsion to Reverse Local Anesthetic–Induced Toxicity , 2007, The Annals of pharmacotherapy.

[6]  N. Sharrock,et al.  Extradural anaesthesia in patients with previous lumbar spine surgery. , 1990, British journal of anaesthesia.

[7]  I. Macnab,et al.  The laminectomy membrane. Studies in its evolution, characteristics, effects and prophylaxis in dogs. , 1974, The Journal of bone and joint surgery. British volume.

[8]  A. van voorthuisen,et al.  Contrast Examination of the Spinal Epidural Space , 1966, Acta radiologica: diagnosis.

[9]  D. Davies,et al.  Randomised comparison of combined spinal-epidural and standard epidural analgesia in labour , 1995, The Lancet.

[10]  E. R. Savolaine,et al.  Anatomy of the human lumbar epidural space: new insights using CT-epidurography. , 1988, Anesthesiology.

[11]  M. Vallejo,et al.  Uniport soft-tip, open-ended catheters versus multiport firm-tipped close-ended catheters for epidural labor analgesia: a quality assurance study. , 2000, Journal of clinical anesthesia.

[12]  S. Hossain,et al.  Quality of Analgesia When Air Versus Saline Is Used for Identification of the Epidural Space in the Parturient , 2000, Regional Anesthesia & Pain Medicine.

[13]  J. Gerancher,et al.  Prospective Examination of Epidural Catheter Insertion , 1996, Anesthesiology.

[14]  H. Benzon,et al.  Delayed Onset of Epidural Anesthesia in Patients with Back Pain , 1981, Anesthesia and analgesia.

[15]  M. Takasaki,et al.  Dural Puncture with a 26-Gauge Spinal Needle Affects Spread of Epidural Anesthesia , 1996, Anesthesia and analgesia.

[16]  S. Segal,et al.  Incidence of epidural catheter replacement in parturients: a retrospective chart review. , 1998, International journal of obstetric anesthesia.

[17]  R. Blomberg The Dorsomedian Connective Tissue Band in the Lumbar Epidural Space of Humans: An Anatomical Study Using Epiduroscopy in Autopsy Cases , 1986, Anesthesia and analgesia.

[18]  The Optimal Distance That a Multiorifice Epidural Catheter Should Be Threaded into the Epidural Space , 1995, Anesthesia and analgesia.

[19]  Q. Hogan Epidural catheter tip position and distribution of injectate evaluated by computed tomography. , 1999, Anesthesiology.

[20]  S. Datta,et al.  Superiority of multi-orifice over single-orifice epidural catheters for labor analgesia and cesarean delivery. , 1997, Journal of clinical anesthesia.

[21]  Q. Hogan Lumbar epidural anatomy. A new look by cryomicrotome section. , 1991, Anesthesiology.