Spatiotemporal Monte Carlo transport methods in x-ray semiconductor detectors: application to pulse-height spectroscopy in a-Se.

PURPOSE The authors describe a detailed Monte Carlo (MC) method for the coupled transport of ionizing particles and charge carriers in amorphous selenium (a-Se) semiconductor x-ray detectors, and model the effect of statistical variations on the detected signal. METHODS A detailed transport code was developed for modeling the signal formation process in semiconductor x-ray detectors. The charge transport routines include three-dimensional spatial and temporal models of electron-hole pair transport taking into account recombination and trapping. Many electron-hole pairs are created simultaneously in bursts from energy deposition events. Carrier transport processes include drift due to external field and Coulombic interactions, and diffusion due to Brownian motion. RESULTS Pulse-height spectra (PHS) have been simulated with different transport conditions for a range of monoenergetic incident x-ray energies and mammography radiation beam qualities. Two methods for calculating Swank factors from simulated PHS are shown, one using the entire PHS distribution, and the other using the photopeak. The latter ignores contributions from Compton scattering and K-fluorescence. Comparisons differ by approximately 2% between experimental measurements and simulations. CONCLUSIONS The a-Se x-ray detector PHS responses simulated in this work include three-dimensional spatial and temporal transport of electron-hole pairs. These PHS were used to calculate the Swank factor and compare it with experimental measurements. The Swank factor was shown to be a function of x-ray energy and applied electric field. Trapping and recombination models are all shown to affect the Swank factor.

[1]  S. Kasap,et al.  Density of localized electronic states in a-Se from electron time-of-flight photocurrent measurements , 2005 .

[2]  J A Rowlands,et al.  X-ray imaging using amorphous selenium: determination of Swank factor by pulse height spectroscopy. , 1998, Medical physics.

[3]  J. C. Knights,et al.  Photogeneration of charge carriers in amorphous selenium , 1974 .

[4]  Sharief F. Babiker,et al.  Finite element Monte Carlo simulation of recess gate compound FFTs , 1996 .

[5]  Niels Bohr,et al.  The penetration of atomic particles through matter , 1948 .

[6]  R. K. Swank Absorption and noise in x‐ray phosphors , 1973 .

[7]  R. Street,et al.  A comparison of x-ray detectors for mouse CT imaging , 2004, Physics in medicine and biology.

[8]  E. Okada,et al.  Hybrid Monte Carlo-diffusion method for light propagation in tissue with a low-scattering region. , 2003, Applied optics.

[9]  Erste Untersuchungen zur Detektion simulierter mammographischer Läsionen , 2010, Der Radiologe.

[10]  Que,et al.  X-ray photogeneration in amorphous selenium: Geminate versus columnar recombination. , 1995, Physical review. B, Condensed matter.

[11]  Erik Fredenberg,et al.  Contrast-enhanced spectral mammography with a photon-counting detector. , 2010, Medical physics.

[12]  J. Sempau,et al.  PENELOPE-2006: A Code System for Monte Carlo Simulation of Electron and Photon Transport , 2009 .

[13]  G. Knoll Radiation detection and measurement , 1979 .

[14]  J. Sempau,et al.  MANTIS: combined x-ray, electron and optical Monte Carlo simulations of indirect radiation imaging systems , 2006, Physics in medicine and biology.

[15]  A. Ferrari,et al.  FLUKA: A Multi-Particle Transport Code , 2005 .

[16]  H. B. Barber,et al.  Charge transport in arrays of semiconductor gamma-ray detectors. , 1995, Physical review letters.

[17]  Aldo Badano,et al.  Recombination models for spatio-temporal Monte Carlo transport of interacting carriers in semiconductors , 2011 .

[18]  Safa Kasap,et al.  Sensitivity reduction mechanisms in amorphous selenium photoconductive x-ray image detectors , 2004 .

[19]  Aldo Badano,et al.  Anisotropic imaging performance in indirect x-ray imaging detectors. , 2006, Medical physics.

[20]  E. Wenkel,et al.  [First experiments for the detection of simulated mammographic lesions: digital full field mammography with a new detector with a double plate of pure selenium]. , 2011, Der Radiologe.

[21]  Aldo Badano,et al.  Monte Carlo simulation of amorphous selenium imaging detectors , 2010, Medical Imaging.

[22]  Joseph Y. Lo,et al.  Digital breast tomosynthesis using an amorphous selenium flat panel detector , 2005, SPIE Medical Imaging.

[23]  Aldo Badano,et al.  penMesh—Monte Carlo Radiation Transport Simulation in a Triangle Mesh Geometry , 2009, IEEE Transactions on Medical Imaging.

[24]  John A. Rowlands,et al.  Measurement of x-ray photogeneration in amorphous selenium , 1999 .

[25]  B. G. Fallone,et al.  Signal formation in amorphous-Se-based x-ray detectors , 2001 .

[26]  T. R. Fewell,et al.  Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography. , 1997, Medical physics.

[27]  C E Dick,et al.  Image information transfer properties of x-ray intensifying screens in the energy range from 17 to 320 keV. , 1993, Medical physics.

[28]  M. P. D. Haas,et al.  Computer simulation of the recombination of the ions in tracks of high-energy electrons in nonpolar liquids , 1991 .