Thermal performance and parameter analysis of a U-pipe evacuated solar tube collector

Abstract This paper proposes a mathematical model for predicting the thermal performance of U-pipe evacuated solar tube (UpEST) collector, which takes into account the temperature distribution along the tube axis and radius. Furthermore, the modeling predictions were validated using experimental data. Theoretical results agreed well with the measured results that validated the feasibility of the mathematical model. The dependence of the thermal efficiency on meteorological conditions and important tube design parameters, including tube size, thermal characteristics (flow rate, heat loss coefficient, absorption coefficient of the selective absorbing coating), was investigated. In particular, the adaptation of collector thermal parameters to meteorological conditions was analyzed. The analysis results will be helpful for UpEST collector optimization design and application.

[1]  Hyunjoo Han,et al.  A three-dimensional performance analysis of all-glass vacuum tubes with coaxial fluid conduit , 2008 .

[2]  Y. Gu,et al.  Development of an equivalent diameter expression for vertical U-tubes used in ground-coupled heat pumps , 1998 .

[3]  Ruobing Liang,et al.  Theoretical and experimental investigation of the filled-type evacuated tube solar collector with U tube , 2011 .

[4]  D. R. Oliver The effect of natural convection on viscous-flow heat transfer in horizontal tubes , 1962 .

[5]  Ruobing Liang,et al.  Thermal performance analysis of the glass evacuated tube solar collector with U-tube , 2010 .

[6]  Simon Furbo,et al.  Theoretical flow investigations of an all glass evacuated tubular collector , 2007 .

[7]  Masud Behnia,et al.  Measurement and simulation of flow rate in a water-in-glass evacuated tube solar water heater , 2005 .

[8]  Zhangyuan Wang,et al.  Theoretical investigation of the performance of a novel loop heat pipe solar water heating system for use in Beijing, China , 2010 .

[9]  Yong Kim,et al.  Thermal performances comparisons of the glass evacuated tube solar collectors with shapes of absorber tube , 2007 .

[10]  Mervyn Smyth,et al.  Experimental field evaluation of novel concentrator augmented solar collectors for medium temperature applications , 2013 .

[11]  Masud Behnia,et al.  Water-in-Glass Evacuated Tube Solar Water Heaters , 2004 .

[12]  G. Harding,et al.  Water-in-glass manifolds for heat extraction from evacuated solar collector tubes , 1984 .

[13]  Graham L. Morrison,et al.  Performance of a Water-in-Glass Evacuated Tube Solar Water Heater , 2001 .

[14]  M. Behnia,et al.  Experimental study of flow ratets through inclined open thermosyphons , 1996 .