Transceive surface coil array for magnetic resonance imaging of the human brain at 4 T

As the static magnetic field strength used in human magnetic resonance imaging increases, the wavelength of the corresponding radiofrequency field becomes comparable to the dimensions of the coil and volume of interest. The dielectric resonance effects that arise in this full wavelength regime may be partially compensated for through the use of surface coils. A novel high‐field (4 T) transceive surface coil array is presented that allows arbitrary surface coil placement and size while maintaining the ability to independently transmit and/or receive through conventional 50‐Ω power amplifiers and preamplifiers, respectively. A ninefold signal‐to‐noise ratio (SNR) increase is shown in close proximity to the transceive array and there is an overall 38% increase throughout the entire brain volume in comparison to the standard hybrid birdcage coil. Furthermore, the ability to independently transmit and receive through each surface coil within this array enables transmit and/or receive‐only fast parallel imaging techniques to be employed while maintaining the increased SNR sensitivity inherent to surface coil designs. Magn Reson Med 54:499–503, 2005. © 2005 Wiley‐Liss, Inc.

[1]  S. Frankel Reactance Networks for Coupling between Unbalanced and Balanced Circuits , 1941, Proceedings of the IRE.

[2]  P. Lauterbur,et al.  The sensitivity of the zeugmatographic experiment involving human samples , 1979 .

[3]  Yudong Zhu,et al.  Parallel excitation with an array of transmit coils , 2004, Magnetic resonance in medicine.

[4]  K. Uğurbil,et al.  Polarization of the RF field in a human head at high field: A study with a quadrature surface coil at 7.0 T , 2002, Magnetic resonance in medicine.

[5]  P. Roemer,et al.  The NMR phased array , 1990, Magnetic resonance in medicine.

[6]  J. Duyn,et al.  Design of a SENSE‐optimized high‐sensitivity MRI receive coil for brain imaging , 2002, Magnetic resonance in medicine.

[7]  Ravi S. Menon,et al.  A transmit‐only/receive‐only (TORO) RF system for high‐field MRI/MRS applications , 2000, Magnetic resonance in medicine.

[8]  R. Constable,et al.  Measurement and correction of transmitter and receiver induced nonuniformities in vivo , 2005, Magnetic resonance in medicine.

[9]  Ravi S. Menon,et al.  Noise properties of a NMR transceiver coil array. , 2004, Journal of magnetic resonance.

[10]  J.A.G. Malherbe Microwave transmission line couplers , 1988 .

[11]  E. McVeigh,et al.  Signal‐to‐noise measurements in magnitude images from NMR phased arrays , 1997 .

[12]  Lawrence L Wald,et al.  Degenerate mode birdcage volume coil for sensitivity‐encoded imaging , 2003, Magnetic resonance in medicine.

[13]  K. Uğurbil,et al.  Transmit and receive transmission line arrays for 7 Tesla parallel imaging , 2005, Magnetic resonance in medicine.

[14]  Renxin Chu,et al.  Scalable multichannel MRI data acquisition system , 2004, Magnetic resonance in medicine.

[15]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.