Measurement and prediction of indoor air quality using a breathing thermal manikin.

UNLABELLED The analyses performed in this paper reveal that a breathing thermal manikin with realistic simulation of respiration including breathing cycle, pulmonary ventilation rate, frequency and breathing mode, gas concentration, humidity and temperature of exhaled air and human body shape and surface temperature is sensitive enough to perform reliable measurement of characteristics of air as inhaled by occupants. The temperature, humidity, and pollution concentration in the inhaled air can be measured accurately with a thermal manikin without breathing simulation if they are measured at the upper lip at a distance of <0.01 m from the face. Body surface temperature, shape and posture as well as clothing insulation have impact on the measured inhaled air parameters. Proper simulation of breathing, especially of exhalation, is needed for studying the transport of exhaled air between occupants. A method for predicting air acceptability based on inhaled air parameters and known exposure-response relationships established in experiments with human subjects is suggested. PRACTICAL IMPLICATIONS Recommendations for optimal simulation of human breathing by means of a breathing thermal manikin when studying pollution concentration, temperature and humidity of the inhaled air as well as the transport of exhaled air (which may carry infectious agents) between occupants are outlined. In order to compare results obtained with breathing thermal manikins, their nose and mouth geometry should be standardized.

[1]  Arsen Krikor Melikov,et al.  Performance of Personalized Ventilation in Conjunction with Mixing and Displacement Ventilation , 2006 .

[2]  O. Valbjørn,et al.  Determination of exposure-response relationships for emissions from building products , 1998 .

[3]  Peter V. Nielsen,et al.  Influence of Geometry of Thermal Manikins on Concentration Distribution and Personal Exposure , 2003 .

[4]  Erik Bjørn Simulation of Human Respiration with Breathing Thermal Manikin , 2000 .

[5]  A. Melikov,et al.  Impact of airflow interaction on inhaled air quality and transport of contaminants in rooms with personalized and total volume ventilation , 2003 .

[6]  W. Fisk,et al.  Ventilation efficiencies of desk-mounted task/ambient conditioning systems. , 1999, Indoor air.

[7]  P. Fanger,et al.  ADAPTATION TO INDOOR AIR POLLUTION , 1992 .

[8]  Henrik Brohus,et al.  Personal Exposure in Displacement Ventilated Rooms , 1996 .

[9]  A. Melikov,et al.  Distribution of carbon dioxide produced by people in a room:: Part 1 - Laboratory study , 2004 .

[10]  A. Melikov Indoor air quality assessment by a breathing thermal manikin , 2000 .

[11]  A. Melikov,et al.  Personalized ventilation: evaluation of different air terminal devices , 2002 .

[12]  P. Fanger,et al.  Impact of Temperature and Humidity on the Perception of Indoor Air Quality , 1998 .

[13]  Arsen Melikov,et al.  Breathing thermal manikins for indoor environment assessment: important characteristics and requirements , 2004, European Journal of Applied Physiology.

[14]  Arsen Krikor Melikov,et al.  New air terminal devices with high efficiency for personalized ventilation application , 2003 .

[15]  P. Höppe,et al.  Temperatures of expired air under varying climatic conditions , 1981, International journal of biometeorology.

[16]  Peter V. Nielsen,et al.  Influence of Geometry of Thermal Manikins on Room Airflow , 2003 .

[17]  Po-zen Wong,et al.  Geometrical models for the high‐frequency dielectric properties of brine saturated sandstones , 1988 .