Advanced three‐dimensional tailored RF pulse for signal recovery in T2*‐weighted functional magnetic resonance imaging

T  2* ‐weighted functional MR images are plagued by signal loss artifacts caused by susceptibility‐induced through‐plane dephasing. We present major advances to the original three‐dimensional tailored RF (3DTRF) pulse method that pre‐compensates the dephasing using three‐dimensional selective excitation. The proposed 3DTRF pulses are designed iteratively with off‐resonance incorporation and with a novel echo‐volumar trajectory that frequency‐encodes in z and phase‐encodes in x,y. We also propose a computational scheme to accelerate the pulse design process. We demonstrate effective signal recovery in a 5‐mm slice in both phantom and inferior brain, using 3DTRF pulses that are only 15.4 ms long. Compared to the original method, the new approach leads to significantly reduced pulse length and enhancement in slice selectivity. 3D images of the slice volume confirm fidelity of the excited phase pattern and slice profile. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.

[1]  Hugo R. Shi,et al.  Toeplitz-based iterative image reconstruction for MRI with correction for magnetic field inhomogeneity , 2005, IEEE Transactions on Signal Processing.

[2]  A Macovski,et al.  Multifrequency interpolation for fast off‐resonance correction , 1997, Magnetic resonance in medicine.

[3]  Roger J. Ordidge,et al.  VOLUMAR IMAGING USING NMR SPIN ECHOES - ECHO-VOLUMAR IMAGING (EVI) AT 0.1-T , 1989 .

[4]  G. Glover,et al.  Rapid in vivo proton shimming , 1991, Magnetic resonance in medicine.

[5]  Yudong Zhu,et al.  Parallel excitation with an array of transmit coils , 2004, Magnetic resonance in medicine.

[6]  Xiaoping Hu,et al.  Simultaneous acquisition of gradient‐echo and asymmetric spin‐echo for single‐shot z‐shim: Z‐SAGA , 2004, Magnetic resonance in medicine.

[7]  R. Turner,et al.  Assessing Study-Specific Regional Variations in fMRI Signal , 2000, NeuroImage.

[8]  Gary H Glover,et al.  Mitigation of susceptibility‐induced signal loss in neuroimaging using localized shim coils , 2005, Magnetic resonance in medicine.

[9]  P. Börnert,et al.  Transmit SENSE , 2003, Magnetic resonance in medicine.

[10]  R Turner,et al.  Optimized EPI for fMRI studies of the orbitofrontal cortex , 2003, NeuroImage.

[11]  Mark Jenkinson,et al.  Optimization of static field homogeneity in human brain using diamagnetic passive shims , 2002, Magnetic resonance in medicine.

[12]  A. Song,et al.  Single‐shot EPI with signal recovery from the susceptibility‐induced losses , 2001, Magnetic resonance in medicine.

[13]  J. Finsterbusch,et al.  Reducing inhomogeneity artifacts in functional MRI of human brain activation-thin sections vs gradient compensation. , 2000, Journal of magnetic resonance.

[14]  Douglas C Noll,et al.  Iterative RF pulse design for multidimensional, small‐tip‐angle selective excitation , 2005, Magnetic resonance in medicine.

[15]  Douglas C Noll,et al.  Multishot 3D slice‐select tailored RF pulses for MRI , 2002, Magnetic resonance in medicine.

[16]  Jeffrey A. Fessler,et al.  Regularized fieldmap estimation in MRI , 2006, 3rd IEEE International Symposium on Biomedical Imaging: Nano to Macro, 2006..

[17]  J. Pauly,et al.  A homogeneity correction method for magnetic resonance imaging with time-varying gradients. , 1991, IEEE transactions on medical imaging.

[18]  G H Glover,et al.  3D z‐shim method for reduction of susceptibility effects in BOLD fMRI , 1999, Magnetic resonance in medicine.

[19]  Peter Boesiger,et al.  Calibration of echo‐planar 2D‐selective RF excitation pulses , 2004, Magnetic resonance in medicine.

[20]  Yang Wang,et al.  Dual‐echo spiral in/in acquisition method for reducing magnetic susceptibility artifacts in blood‐oxygen‐level‐dependent functional magnetic resonance imaging , 2006, Magnetic resonance in medicine.

[21]  Yong Man Ro,et al.  Reduction of susceptibility artifact in gradient‐echo imaging , 1992, Magnetic resonance in medicine.

[22]  Christian Schwarzbauer,et al.  Positive or negative blips? The effect of phase encoding scheme on susceptibility-induced signal losses in EPI , 2005, NeuroImage.

[23]  Charles R. G. Guttmann,et al.  Multiresolution Data Acquisition and Detection in Functional MRI , 2001, NeuroImage.

[24]  Jeffrey A. Fessler,et al.  Fast, iterative image reconstruction for MRI in the presence of field inhomogeneities , 2003, IEEE Transactions on Medical Imaging.

[25]  G. Glover,et al.  Spiral‐in/out BOLD fMRI for increased SNR and reduced susceptibility artifacts , 2001, Magnetic resonance in medicine.

[26]  Seung-Schik Yoo,et al.  Selection of voxel size and slice orientation for fMRI in the presence of susceptibility field gradients: application to imaging of the amygdala , 2003, NeuroImage.

[27]  V A Stenger,et al.  Three‐dimensional tailored RF pulses for the reduction of susceptibility artifacts in T*2‐weighted functional MRI , 2000, Magnetic resonance in medicine.

[28]  Jeffrey A. Fessler,et al.  Nonuniform fast Fourier transforms using min-max interpolation , 2003, IEEE Trans. Signal Process..