Study on transformer inrush current and CT saturation as well as the impact of their coupling effect on protection

For the construction of the smart grid, protection needs to be accurately measured, and the current transformer needs to correctly transfer the transient process. The transient process of nonlinear ferromagnetic elements mainly includes the transformer inrush current and CT saturation. Differential protection misoperation is rarely caused by a single factor. It involves the coupling effect between the transformer inrush current and CT saturation. In this paper, the magnetizing inrush current and sympathetic inrush current and the CT saturation are studied from the aspects of principle analysis and digital simulation. Based on an accident, the coupling between the transformer inrush and CT saturation and its impacts on the differential protection are analyzed. Finally, methods to this problem are discussed.

[1]  Wu Zhiyong Principle and characteristics of transformer sympathetic inrush , 2011 .

[2]  Xj Electric,et al.  Theory Analysis of the Sympathetic Inrush in Operating Transformers , 2005 .

[3]  Wang Dewen Basic Framework and Key Technology for a New Generation of Data Center in Electric Power Corporation Based on Cloud Computation , 2012 .

[4]  Li Li-xin,et al.  Research on sympathetic inrush in operating transformer , 2006 .

[5]  Zhao Ping Analysis of Influence Factors of Sympathetic Inrush on Differential Protection and Its Solutions , 2009 .

[6]  You Dahai,et al.  Reason of Differential Protection Mal-operation Caused by Complex Sympathetic Inrush and Its Countermeasure , 2011 .

[7]  Chen De Research of the improved time difference method to distinguish TA's saturation , 2001 .

[8]  Xianggen Yin,et al.  Modeling and analysis for practical CT based on transient test and parameter identification , 2016 .

[9]  Li Chen THE INFLULENCE AND COUNTERMEASURE TO TRANSFORMER DIFFERENTIAL PROTECTION OF CT PARTIAL TRANSIENT SATURATION CAUSED BY EXTERNAL FAULT REMOVAL , 2005 .

[10]  Udaya Annakkage,et al.  A current transformer model based on the Jiles-Atherton theory of ferromagnetic hysteresis , 2000 .

[11]  Yuan Ji The transient saturation of current transformer and its application calculation , 2002 .

[12]  Li De-jia,et al.  Physical Mechanism of Sympathetic Inrush of Transformer and Its Influence on Differential Protection , 2005 .

[13]  Jun Gu,et al.  The influence and countermeasure to transformer differential protection of CT saturation caused by external fault removal , 2008, 2008 International Conference on Electrical Machines and Systems.

[14]  Zhang Zhi-mei Study on Comprehensive TA Saturation Criterion for Transformer Differential Protection , 2007 .

[15]  Huang Ming-yu Analysis and research on steady and transient saturation characteristics of CT , 2009 .

[16]  Zhang Jian-Song,et al.  Principle and Influencing Factors of the Transformer Sympathetic Inrush , 2005 .