Building energy efficiency assessment by integrated strategies : dynamic simulation , sensitivity analysis and experimental activity

Thermal and energy dynamic analysis of buildings is a well-established procedure to evaluate the effective building energy performance, considering real climate. The proposal of new technical solutions and innovative strategies to be applied for both summer and winter period has a fundamental role also considering the IPCC suggestions and the EPBD European Directive implementation. In this paper a synthetic but also exhaustive method for thermal dynamic analysis of buildings is proposed. It is based on performance levels assignment, defined by proper non-dimensional indexes (TDI, Thermal Deviation Index) that allow to express the building behavior and the sensitivity analysis results, in relationship to the climatic context. The proposed methodology is then applied to different case studies consisting of numerical prototypes of free-running residential buildings to evaluate first the architectural shape role and then the sensitivity of different envelope features, characterized also by experimental measurements conducted on real Italian residential buildings. The prototypes are designed to optimize respectively summer or winter energy performance or to represent the typical Italian house before and after energy efficiency regulation coming into force. To better define some important parameters necessary to calibrate the numerical models, experimental activities are carried out. In particular, thermal insulation level and roof reflectance, characterized by means of spectrophotometrical measurements, are measured both in the case of an old traditional Italian building and in the case of a new one. The results of the dynamic analysis, concerning all the considered variables (mass and insulation, roof reflectance, Solar Heat Gain Coefficients of glasses, weather data, etc.) are defined by TDI values that make it possible to evaluate and to compare the role of each element for defining the building thermal performance, also related to the specific climatic context. The results obtained using the proposed method are also compared with those obtained from existing procedures. In particular the TDI values are correlated to an adaptive comfort indicator, for verifying how much the TDI could be effective for evaluating free-running buildings thermal performance during both summer and winter period.

[1]  Jan Hensen,et al.  Thermal comfort in residential buildings: Comfort values and scales for building energy simulation , 2009 .

[2]  H. Akbari,et al.  Measuring solar reflectance—Part II: Review of practical methods , 2010 .

[3]  H. Akbari,et al.  Measuring solar reflectance—Part I: Defining a metric that accurately predicts solar heat gain , 2010 .

[4]  A. Tsangrassoulis,et al.  On the influence of building design, occupants and heat waves on comfort and greenhouse gas emissions in naturally ventilated offices. A study based on the EN 15251 adaptive thermal comfort model in Athens, Greece , 2010 .

[5]  Thermal insulation. Building elements. In-situ measurement of thermal resistance and thermal transmittance , 2022 .

[6]  Daniel E. Fisher,et al.  EnergyPlus: creating a new-generation building energy simulation program , 2001 .

[7]  Christian Ghiaus,et al.  Free-running building temperature and HVAC climatic suitability , 2003 .

[8]  Caterina Di Perna,et al.  Influence of the internal inertia of the building envelope on summertime comfort in buildings with h , 2011 .

[9]  Laura Bellia,et al.  Solar gain and building envelope: the surface factor , 2010 .

[10]  M. Santamouris,et al.  On the development, optical properties and thermal performance of cool colored coatings for the urban environment , 2007 .

[11]  Stefano Tarantola,et al.  Application of global sensitivity analysis of model output to building thermal simulations , 2008 .

[12]  L. L. Boyer,et al.  The Framework of an Optimization Model for the Thermal Design of Building Envelopes , 1994 .

[13]  Mohammad S. Al-Homoud,et al.  Optimum thermal design of air-conditioned residential buildings , 1997 .

[14]  Akira Hoyano,et al.  A numerical simulation tool for predicting the impact of outdoor thermal environment on building energy performance , 2009 .

[15]  Joseph C. Lam,et al.  Sensitivity analysis of energy performance of office buildings , 1996 .

[16]  Mohammad S. Al-Homoud,et al.  Parametric analysis of alternative energy conservation measures in an office building in hot and humid climate , 2007 .

[17]  Enrico Fabrizio,et al.  The impact of indoor thermal conditions, system controls and building types on the building energy demand , 2008 .

[18]  Iso Tc,et al.  Thermal Performance of Windows, Doors and Shading Devices — Detailed Calculations , 2000 .

[19]  Jon Hand,et al.  CONTRASTING THE CAPABILITIES OF BUILDING ENERGY PERFORMANCE SIMULATION PROGRAMS , 2008 .

[20]  Enrico Fabrizio,et al.  A model to design and optimize multi-energy systems in buildings at the design concept stage , 2010 .

[21]  Zerrin Yilmaz,et al.  Evaluation of energy efficient design strategies for different climatic zones: Comparison of thermal performance of buildings in temperate-humid and hot-dry climate , 2007 .

[22]  Nm Bouchlaghem,et al.  Optimising the design of building envelopes for thermal performance , 2000 .

[23]  Zhiqiang John Zhai,et al.  Sensitivity analysis and application guides for integrated building energy and CFD simulation , 2006 .

[24]  Borong Lin,et al.  DISCUSSION ON METHODOLOGY OF APPLYING BUILDING THERMAL SIMULATIONIN IN CONCEPTUAL DESIGN , 2007 .

[25]  Clarice Bleil De Souza,et al.  Thermal performance simulation from an architectural design viewpoint , 2007 .

[26]  I. G. Capeluto,et al.  Strategic decision-making for intelligent buildings: Comparative impact of passive design strategies and active features in a hot climate , 2008 .

[27]  S. Schneider,et al.  A contribution of Working Groups I, II and III to the Third Assessment Report of the Intergovernment Panel on Climate Change , 2001 .

[28]  Danny S. Parker,et al.  Roof solar reflectance and cooling energy use: field research results from Florida , 1997 .

[29]  Bjarne W. Olesen,et al.  The philosophy behind EN15251: Indoor environmental criteria for design and calculation of energy performance of buildings , 2007 .

[30]  Henrik Brohus,et al.  Application of sensitivity analysis in design of sustainable buildings , 2009 .