A predictive fatigue model. II. Predicting the effect of resting times on fatigue

For pt. I see ibid., vol. 10, no. 1, p. 48-58 (2002). We have recently developed a force- and fatigue-model system that accurately predicted the effect of stimulation frequency on muscle fatigue (see pt. I). The data used to test the model were produced by stimulation trains with resting times of 500 ms. Because the resting times between stimulation trains affect muscle fatigue, this study tested the model's ability to predict the effect of resting times on fatigue. In addition, because this study included different subjects than those used to develop the model, the validity of the model could be tested. Data were collected from human quadriceps femoris muscles using fatigue protocols that included resting times of 500, 750, or 1000 ms. Our results showed that the model predicted fatigue as being a decreasing function of resting time, which was consistent with experimental data. Reliability tests between the experimental data and predictions showed interclass correlation coefficients of 0.97, 0.95, and 0.81 for the initial, final, and percentage decline in peak forces, respectively, suggesting strong agreement between the experimental data and the predictions by the model. The success of our current force- and fatigue-model system helps to validate the model and suggests its potential use in identifying the optimal activation pattern during clinical application of functional electrical stimulation.

[1]  J. J. Woods,et al.  Excitation frequency and muscle fatigue: Electrical responses during human voluntary and stimulated contractions , 1979, Experimental Neurology.

[2]  B. Bigland-ritchie,et al.  Excitation frequency and muscle fatigue: Mechanical responses during voluntary and stimulated contractions , 1979, Experimental Neurology.

[3]  C D Marsden,et al.  "Muscular wisdom" that minimizes fatigue during prolonged effort in man: peak rates of motoneuron discharge and slowing of discharge during fatigue. , 1983, Advances in neurology.

[4]  J P Paul,et al.  Hybrid FES orthosis incorporating closed loop control and sensory feedback. , 1988, Journal of biomedical engineering.

[5]  E. Marsolais,et al.  Energy costs of walking and standing with functional neuromuscular stimulation and long leg braces. , 1988, Archives of physical medicine and rehabilitation.

[6]  A. McComas,et al.  Relationship between numbers and frequencies of stimuli in human muscle fatigue. , 1988, Journal of applied physiology.

[7]  L Bevan,et al.  The effect of the stimulation pattern on the fatigue of single motor units in adult cats. , 1992, The Journal of physiology.

[8]  D G Stuart,et al.  Neurobiology of muscle fatigue. , 1992, Journal of applied physiology.

[9]  Mitsumasa Iwamoto,et al.  Generation of Maxwell displacement current from spread monolayers containing azobenzene , 1992 .

[10]  R. Lieber,et al.  Torque history of electrically stimulated human quadriceps: Implications for stimulation therapy , 1993, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[11]  S. Binder-Macleod,et al.  Fatigability of human quadriceps femoris muscle following anterior cruciate ligament reconstruction. , 1993, Medicine and science in sports and exercise.

[12]  R. Fitts Cellular mechanisms of muscle fatigue. , 1994, Physiological reviews.

[13]  U. Bogataj,et al.  The rehabilitation of gait in patients with hemiplegia: a comparison between conventional therapy and multichannel functional electrical stimulation therapy. , 1995, Physical therapy.

[14]  S A Binder-Macleod,et al.  Effects of stimulation intensity on the physiological responses of human motor units. , 1995, Medicine and science in sports and exercise.

[15]  J. Mizrahi,et al.  A model of fatigue and recovery in paraplegic's quadriceps muscle subjected to intermittent FES. , 1996, Journal of biomechanical engineering.

[16]  J. Mizrahi,et al.  Fatigue in Muscles Activated by Functional Electrical Stimulation , 1997 .

[17]  W. Durfee,et al.  Surface EMG as a fatigue indicator during FES-induced isometric muscle contractions. , 1997, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[18]  J Mizrahi,et al.  Predicted and measured muscle forces after recoveries of differing durations following fatigue in functional electrical stimulation. , 1997, Artificial organs.

[19]  S A Binder-Macleod,et al.  Reduction of the fatigue-induced force decline in human skeletal muscle by optimized stimulation trains. , 1997, Archives of physical medicine and rehabilitation.

[20]  J Mizrahi,et al.  Muscle fatigue in interrupted stimulation: Effect of partial recovery on force and EMG dynamics. , 1997, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[21]  S. Binder-Macleod,et al.  New look at force-frequency relationship of human skeletal muscle: effects of fatigue. , 1998, Journal of neurophysiology.

[22]  J Ding,et al.  Two-step, predictive, isometric force model tested on data from human and rat muscles. , 1998, Journal of applied physiology.

[23]  J Ding,et al.  Development of a mathematical model that predicts optimal muscle activation patterns by using brief trains. , 2000, Journal of applied physiology.

[24]  S. Binder-Macleod,et al.  A predictive model of fatigue in human skeletal muscles. , 2000, Journal of applied physiology.

[25]  S. Binder-Macleod,et al.  A predictive fatigue model. I. Predicting the effect of stimulation frequency and pattern on fatigue , 2002, IEEE Transactions on Neural Systems and Rehabilitation Engineering.