Global optimization for overall HVAC systems––Part I problem formulation and analysis

This paper presents the global optimization technologies for overall heating, ventilating and air conditioning (HVAC) systems. The objective function of global optimization and constraints are formulated based on mathematical models of the major components. All these models are associated with power consumption components and heat exchangers for transferring cooling load. The characteristics of all the major components are briefly introduced by models, and the interactions between them are analyzed and discussed to show the complications of the problem. According to the characteristics of the operating components, the complicated original optimization problem for overall HVAC systems is transformed and simplified into a compact form ready for optimization.

[1]  J. B. Rishel,et al.  Proper control of HVAC variable speed pumps , 1998 .

[2]  W. Kirsner Designing for 42°F chilled water supply temperature : Does it save energy ? , 1998 .

[3]  Richard C. Diamond,et al.  Performance validation and energy analysis of HVAC systems using simulation , 2000 .

[4]  S. B. Austin Chilled water system optimization , 1993 .

[5]  J. Braun Methodologies for the Design and Control of Central Cooling Plants , 1988 .

[6]  Jan F. Kreider,et al.  Heating and Cooling of Buildings: Design for Efficiency , 1994 .

[7]  YAOWEN WANG,et al.  Model of Coils and Heat Exchangers for HVAC System Simulation and Optimization , 2002 .

[8]  Thomas B. Hartman,et al.  Design Issues of Variable Chilled-Water Flow Through Chillers , 1998 .

[9]  T. Hartman Packaging DDC networks with variable speed drives , 1998 .

[10]  W. Kirsner 3 gpm/ton condenser water flow rate: Does it waste energy? , 1996 .

[11]  Refrigerating ASHRAE handbook and product directory /published by the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc , 1977 .

[12]  Barrett A. Flake Parameter Estimation and Optimal Supervisory Control of Chilled Water Plants , 1998 .

[13]  Stoecker Procedures for simulating the performance of components and systems for energy calculations. Third edition , 1975 .

[14]  Wenjian Cai,et al.  A Universal Engineering Model For Cooling Towers , 2002 .

[15]  S. V. Shelton,et al.  Cooling tower optimization for centrifugal chillers , 1991 .

[16]  Sanford Klein,et al.  Applications of optimal control to chilled water systems without storage , 1989 .

[17]  J. M. House,et al.  Optimal control of building and HVAC systems , 1995, Proceedings of 1995 American Control Conference - ACC'95.

[18]  H. Bynum,et al.  Variable flow : A control engineer's perspective , 1999 .

[19]  Vaughn Bradshaw Building Control Systems , 1985 .

[20]  Wenjian Cai,et al.  A New Approach To Set Point Control In Chilled Water Loops , 2002 .

[21]  G. Avery Controlling chillers in variable flow systems , 1998 .