Design of an optimized photovoltaic and microturbine hybrid power system for a remote small community: Case study of Palestine

Hybrid systems are defined as systems that utilize more than one energy source to supply a certain load. The implementation of a hybrid system that is based upon Photovoltaic (PV) to supply power to remote and isolated locations is considered a viable option. This is especially true for areas that receive sufficient amounts of annual solar radiation. While analysis of hybrid systems that depend on diesel generators as backup sources can be found in many previous research works, detailed techno economic analysis of hybrid systems that depend on microturbines as backup sources are less addressed. A techno-economic analysis and the design of a complete hybrid system that comprises of Photovoltaic (PV) panels, a battery system, and a microturbine as a backup power source for a remote community is presented in this paper. The investigation of the feasibility of using the microturbines as backup sources in the hybrid systems is one of the purposes of this study. A scenario depending on PV standalone system and other scenario depending on microturbine only were also studied in this paper. The comparison between different scenarios with regards to the cost of energy and pollutant emissions was also conducted. A simulation program was developed to optimize both the sizes of the PV system and the battery bank, and consequently determine the detailed specifications of the different components that make up the hybrid system. The optimization of the PV tilt angle that maximizes the annual energy production was also carried out. The effect of the variation of some parameters on the cost of energy was duly evaluated. Powering a rural community using microturbine alone indicates lower values of cost of energy (COE) production compared to the hybrid system in which a combination of PV panels, battery bank and microturbine has been used. The difference is very small and taking into account the environmental effect of the microturbine surely will make the hybrid system with limited running hours of the microturbine more attractive. Furthermore, as it is obvious from the sensitivity analysis, any reduction in the price of the PV panels or any increase in the natural gas price will make the hybrid system economically and environmentally more attractive.

[1]  Abdul Jabbar N. Khalifa On the effect of cover tilt angle of the simple solar still on its productivity in different seasons and latitudes , 2011 .

[2]  Heikki N. Koivo,et al.  Online management genetic algorithms of microgrid for residential application , 2012 .

[3]  Tracy K. N. Sweet,et al.  Photovoltaic applications for off-grid electrification using novel multi-level inverter technology with energy storage , 2012 .

[4]  Vigna Kumaran Ramachandaramurthy,et al.  Techno-economical optimization of hybrid pv/wind/battery system using Neuro-Fuzzy , 2011 .

[5]  M. M. Ardehali,et al.  Particle swarm optimization based fuzzy logic controller for autonomous green power energy system with hydrogen storage , 2013 .

[6]  Joshua M. Pearce Expanding Photovoltaic Penetration with Residential Distributed Generation from Hybrid Solar Photovoltaic Combined Heat and Power Systems , 2009 .

[7]  K. R. Genwa,et al.  Energy efficiency, solar energy conversion and storage in photogalvanic cell , 2013 .

[8]  Teuku Meurah Indra Mahlia,et al.  Techno-economic analysis of an optimized photovoltaic and diesel generator hybrid power system for remote houses in a tropical climate. , 2013 .

[9]  Teuku Meurah Indra Mahlia,et al.  Analysis and evaluation of various aspects of solar radiation in the Palestinian territories , 2013 .

[10]  Tariq Muneer,et al.  Neural network based method for conversion of solar radiation data , 2013 .

[11]  Marwan M. Mahmoud,et al.  Techno-economic feasibility of energy supply of remote villages in Palestine by PV-systems, diesel generators and electric grid , 2006 .

[12]  Guangyu Liu,et al.  A general modeling method for I–V characteristics of geometrically and electrically configured photovoltaic arrays , 2011 .

[13]  Ahmed M. A. Haidar,et al.  Optimal configuration assessment of renewable energy in Malaysia , 2011 .

[14]  W. Beckman,et al.  Solar Engineering of Thermal Processes , 1985 .

[15]  Mohsen Kalantar,et al.  Dynamic behavior of a stand-alone hybrid power generation system of wind turbine, microturbine, solar array and battery storage , 2010 .

[16]  Alberto Coronas,et al.  Integration of absorption cooling systems into micro gas turbine trigeneration systems using biogas: Case study of a sewage treatment plant , 2009 .

[17]  Zita Vale,et al.  An integrated approach for distributed energy resource short-term scheduling in smart grids considering realistic power system simulation , 2012 .

[18]  Teuku Meurah Indra Mahlia,et al.  Techno-economic analysis of a wind–solar hybrid renewable energy system with rainwater collection feature for urban high-rise application , 2011 .

[19]  Teuku Meurah Indra Mahlia,et al.  A review on the pattern of electricity generation and emission in Iran from 1967 to 2008 , 2010 .

[20]  Nasrudin Abd Rahim,et al.  A review on global solar energy policy , 2011 .

[21]  A. Regattieri,et al.  Multi-parameter analysis for the technical and economic assessment of photovoltaic systems in the main European Union countries , 2013 .

[22]  Ramchandra Bhandari,et al.  Electrification using solar photovoltaic systems in Nepal , 2011 .

[23]  José L. Bernal-Agustín,et al.  Multi-objective design of PV–wind–diesel–hydrogen–battery systems , 2008 .

[24]  Rustu Eke,et al.  Performance analysis of a multi crystalline Si photovoltaic module under Mugla climatic conditions in Turkey , 2013 .

[25]  S. M. Mousavi,et al.  An autonomous hybrid energy system of wind/tidal/microturbine/battery storage , 2012 .

[26]  Caisheng Wang,et al.  Power management of a stand-alone hybrid wind-microturbine distributed generation system , 2009, 2009 IEEE Power Electronics and Machines in Wind Applications.

[27]  Teuku Meurah Indra Mahlia,et al.  Fuel consumption and emission prediction by Iranian power plants until 2025 , 2011 .

[28]  Abdel-Karim Daud,et al.  Design of isolated hybrid systems minimizing costs and pollutant emissions , 2012 .

[29]  J. K. Kaldellis,et al.  Energy balance analysis of combined photovoltaic–diesel powered telecommunication stations , 2011 .

[30]  Abdallah A. Abdallah,et al.  PV solar system feasibility study , 2013 .

[31]  Yunho Hwang,et al.  Potential energy benefits of integrated refrigeration system with microturbine and absorption chiller , 2004 .

[32]  Nejib Hamrouni,et al.  Solar radiation and ambient temperature effects on the performances of a PV pumping system , 2008, Journal of Renewable Energies.

[33]  M. G. De Giorgi,et al.  Performance measurements of monocrystalline silicon PV modules in South-eastern Italy , 2013 .

[34]  John K. Kaldellis,et al.  Cost benefit analysis of a photovoltaic-energy storage electrification solution for remote islands , 2009 .

[35]  Kashif Ishaque,et al.  An improved modeling method to determine the model parameters of photovoltaic (PV) modules using differential evolution (DE) , 2011 .

[36]  M. I. Dieste-Velasco,et al.  Performance analysis of PV plants: Optimization for improving profitability , 2012 .

[37]  Rashid Ansumana,et al.  Evaluating the impact of adding energy storage on the performance of a hybrid power system , 2011 .

[38]  Teuku Meurah Indra Mahlia,et al.  Current utilization of microturbines as a part of a hybrid system in distributed generation technology , 2013 .

[39]  Riccardo Minciardi,et al.  Modeling and optimization of a hybrid system for the energy supply of a “Green” building , 2012 .

[40]  Teuku Meurah Indra Mahlia,et al.  Characterization of PV panel and global optimization of its model parameters using genetic algorithm , 2013 .

[41]  Josua P. Meyer,et al.  Feasibility study of a wind-pv-diesel hybrid power system for a village , 2012 .

[42]  José L. Bernal-Agustín,et al.  Multi-objective optimization minimizing cost and life cycle emissions of stand-alone PV–wind–diesel systems with batteries storage , 2011 .

[43]  Lacour M Ayompe,et al.  Measured performance of a 1.72 kW rooftop grid connected photovoltaic system in Ireland , 2011 .

[44]  Saad Mekhilef,et al.  Effect of dust, humidity and air velocity on efficiency of photovoltaic cells , 2012 .

[45]  M. Abdolzadeh,et al.  Prediction of the optimum slope and surface azimuth angles using the Genetic Algorithm , 2011 .