X-ray Performance Evaluation of the Dexela CMOS APS X-ray Detector Using Monochromatic Synchrotron Radiation in the Mammographic Energy Range

Digital detectors based on complementary metal-oxide-semiconductors (CMOS) active pixel sensor (APS) technology have been introduced recently in many scientific applications. This work is focused on the X-ray performance evaluation of a novel CMOS APS detector in low energy medical imaging applications using monochromatic synchrotron radiation (i.e., 17-35 keV), which also allows studying how the performance varies with energy. The CMOS sensor was coupled to a Thallium-activated structured cesium iodide (CsI:Tl) scintillator and the detector's X-ray performance evaluation was carried out in terms of sensitivity, presampling modulation transfer function (pMTF), normalized noise power spectrum (NNPS) and the resulting detective quantum efficiency (DQE). A Monte Carlo simulation was used to validate the experimentally measured low frequency DQE. Finally, the effect of iodine's secondary generated K-fluorescence X-rays on pMTF and DQE results was evaluated. Good agreement (within 5%) was observed between the Monte Carlo and experimentally measured low frequency DQE results. A CMOS APS detector was characterized for the first time over a wide range of low energies covering the mammographic spectra. The detector's performance is limited mainly by the detectability of the scintillator. Finally, we show that the current data could be used to calculate the detector's pMTF, NNPS and DQE for any mammographic spectral shape within the investigated energies.

[1]  Felix Diekmann,et al.  The Future of Breast Cancer Diagnostics , 2008, Breast Care.

[2]  John M Lewin,et al.  Dual-energy contrast-enhanced digital subtraction mammography: feasibility. , 2003, Radiology.

[3]  N W Marshall,et al.  A comparison between objective and subjective image quality measurements for a full field digital mammography system , 2006, Physics in medicine and biology.

[4]  James R. Janesick Lux transfer: Complementary metal oxide semiconductors versus charge-coupled devices , 2002 .

[5]  J Blakesley,et al.  Signal and noise transfer properties of CMOS based active pixel flat panel imager coupled to structured CsI:Tl. , 2008, Medical physics.

[6]  J. D. Valentine,et al.  Light yield nonproportionality of CsI(Tl), CsI(Na), and YAP , 1997 .

[7]  K Doi,et al.  Studies of x-ray energy absorption and quantum noise properties of x-ray screens by use of Monte Carlo simulation. , 1984, Medical physics.

[8]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[9]  Lucia Mancini,et al.  Medical applications of synchrotron radiation at the SYRMEP beamline of ELETTRA , 2005 .

[10]  N W Marshall Detective quantum efficiency measured as a function of energy for two full-field digital mammography systems. , 2009, Physics in medicine and biology.

[11]  David N. Burrows,et al.  Characterization of Si hybrid CMOS detectors for use in the soft x-ray band , 2013, Optics & Photonics - Optical Engineering + Applications.

[12]  James T Dobbins,et al.  Digital x-ray tomosynthesis: current state of the art and clinical potential. , 2003, Physics in medicine and biology.

[13]  John M. Boone,et al.  X-Ray Production, Interaction, and Detection in Diagnostic Imaging , 2000 .

[14]  David N. Burrows,et al.  Recent progress on developments and characterization of hybrid CMOS x-ray detectors , 2012, Other Conferences.

[15]  I. Cunningham Applied Linear-Systems Theory , 2000 .

[16]  A large-area CMOS imager as an X-ray detector for synchrotron radiation experiments. , 2004, Journal of synchrotron radiation.

[17]  Anastasios C. Konstantinidis,et al.  Evaluation of Digital X-Ray Detectors for Medical Imaging Applications , 2012 .

[18]  James R. Janesick Charge-coupled CMOS and hybrid detector arrays , 2004, SPIE Optics + Photonics.

[19]  D. Kopans,et al.  Tomographic mammography using a limited number of low-dose cone-beam projection images. , 2003, Medical physics.

[20]  Martin J Yaffe,et al.  A CdZnTe slot-scanned detector for digital mammography. , 2002, Medical physics.

[21]  D. Kopans,et al.  Digital tomosynthesis in breast imaging. , 1997, Radiology.

[22]  E Castelli,et al.  Mammography with synchrotron radiation: phase-detection techniques. , 2000, Radiology.

[23]  David N. Burrows,et al.  Characterization of Si hybrid CMOS detectors for use in the soft X-ray band , 2013 .

[24]  A. El Gamal,et al.  CMOS image sensors , 2005, IEEE Circuits and Devices Magazine.

[25]  James T. Dobbins Image Quality Metrics for Digital Systems , 2000 .

[26]  John M. Boone Spectral modeling and compilation of quantum fluence in radiography and mammography , 1998, Medical Imaging.

[27]  Elizabeth A Krupinski,et al.  Digital radiography image quality: image acquisition. , 2007, Journal of the American College of Radiology : JACR.

[28]  I. Kandarakis,et al.  Overestimations in zero frequency DQE of x-ray imaging converters assessed by Monte Carlo techniques based on the study of energy impartation events. , 2011, Medical physics.

[29]  James R. Janesick History, Operation, Performance, Design, Fabrication and Theory , 2001 .

[30]  A Fenster,et al.  A time-delay integration charge-coupled device camera for slot-scanned digital radiography. , 1990, Medical physics.

[31]  F R Verdun,et al.  Image quality assessment in digital mammography: part I. Technical characterization of the systems , 2011, Physics in medicine and biology.

[32]  Sunetra K. Mendis,et al.  CMOS active pixel image sensor , 1994 .

[33]  J A Rowlands,et al.  X-ray detectors for digital radiography. , 1997, Physics in medicine and biology.

[34]  J H Siewerdsen,et al.  Strategies to improve the signal and noise performance of active matrix, flat-panel imagers for diagnostic x-ray applications. , 2000, Medical physics.

[35]  Alessandro Olivo,et al.  Technical Note: modification of the standard gain correction algorithm to compensate for the number of used reference flat frames in detector performance studies. , 2011, Medical physics.

[36]  Emilio Quaia,et al.  The SYRMEP Beamline of Elettra: Clinical Mammography and Bio‐medical Applications , 2010 .

[37]  A. Vacchi,et al.  Mammography with Synchrotron Radiation : Phase-Detection Techniques 1 , 2022 .

[38]  Eric R. Fossum,et al.  CMOS image sensors: electronic camera on a chip , 1995, Proceedings of International Electron Devices Meeting.

[39]  Joaquim Salvi,et al.  Review of CMOS image sensors , 2006, Microelectron. J..

[40]  Ehsan Samei,et al.  An experimental comparison of detector performance for computed radiography systems. , 2002, Medical physics.

[41]  Thorsten Graeve,et al.  High-resolution CMOS imaging detector , 2001, SPIE Medical Imaging.

[42]  M B Williams,et al.  Analysis of the detective quantum efficiency of a developmental detector for digital mammography. , 1999, Medical Physics (Lancaster).

[43]  Ulrich Neitzel,et al.  Accuracy of a simple method for deriving the presampled modulation transfer function of a digital radiographic system from an edge image. , 2003, Medical physics.

[44]  J. Sempau,et al.  MANTIS: combined x-ray, electron and optical Monte Carlo simulations of indirect radiation imaging systems , 2006, Physics in medicine and biology.

[45]  Martin Spahn,et al.  Flat detectors and their clinical applications , 2005, European Radiology.

[46]  R. B. Murray,et al.  Scintillation Process in CsI(Tl). I. Comparison with Activator Saturation Model , 1963 .

[47]  R. Close,et al.  Regularization method for scatter-glare correction in fluoroscopic images. , 1999, Medical physics.

[48]  E. Samei,et al.  A method for measuring the presampled MTF of digital radiographic systems using an edge test device. , 1998, Medical physics.

[49]  Falko Busse,et al.  Design and performance of a high-quality cardiac flat detector , 2002, SPIE Medical Imaging.

[50]  Goran Ristic,et al.  X-ray imaging performance of structured cesium iodide scintillators. , 2004, Medical physics.

[51]  John A. Rowlands,et al.  Large-area solid state detector for radiology using amorphous selenium , 1992, Medical Imaging.

[52]  G. Entine,et al.  Structured CsI(Tl) scintillators for X-ray imaging applications , 1997, 1997 IEEE Nuclear Science Symposium Conference Record.

[53]  S Rudin,et al.  Super-global distortion correction for a rotational C-arm x-ray image intensifier. , 1999, Medical physics.

[54]  Danny Scheffer,et al.  A wafer scale active pixel CMOS image sensor for generic x-ray radiology , 2007, SPIE Medical Imaging.

[55]  Goran Ristic,et al.  Screen optics effects on detective quantum efficiency in digital radiography: zero-frequency effects. , 2006, Medical physics.

[56]  D. Jaffray,et al.  A ghost story: spatio-temporal response characteristics of an indirect-detection flat-panel imager. , 1999, Medical physics.

[57]  Gordon E Mawdsley,et al.  Lag and ghosting in a clinical flat-panel selenium digital mammography system. , 2006, Medical physics.

[58]  Vivek V. Nagarkar,et al.  Improved x-ray converters for CCD-based crystallography detectors , 1995, Optics & Photonics.

[59]  N J Hangiandreou,et al.  Effects of x-ray spectra on the DQE of a computed radiography system. , 2001, Medical physics.

[60]  Serge Muller,et al.  Development of contrast digital mammography. , 2002, Medical physics.

[61]  Emilio Quaia,et al.  Mammography with synchrotron radiation: first clinical experience with phase-detection technique. , 2011, Radiology.

[62]  J Yorkston,et al.  Demonstration of megavoltage and diagnostic x-ray imaging with hydrogenated amorphous silicon arrays. , 1992, Medical physics.

[63]  B. L. Beron,et al.  The Fluorescent Response of NaI(Tl), CsI(Tl), CsI(Na) and CaF2(Eu) to X-Rays and Low Energy Gamma Rays , 1967 .

[64]  Ioannis S Kandarakis,et al.  Modeling granular phosphor screens by Monte Carlo methods. , 2006, Medical physics.

[65]  R. K. Swank Absorption and noise in x‐ray phosphors , 1973 .

[66]  J. H. Hubbell,et al.  Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients 1 keV to 20 MeV for Elements Z = 1 to 92 and 48 Additional Substances of Dosimetric Interest , 1995 .

[67]  I. Kandarakis,et al.  The imaging performance of compact Lu2O3:Eu powdered phosphor screens: Monte Carlo simulation for applications in mammography. , 2009, Medical physics.

[68]  Gyuseong Cho,et al.  Development and evaluation of a digital radiographic system based on CMOS image sensor , 2000, 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149).

[69]  Mehmet Akif Erismis,et al.  On the processing aspects of high performance hybrid backside illuminated CMOS imagers , 2010 .

[70]  Alessandro Olivo,et al.  Technical note: further development of a resolution modification routine for the simulation of the modulation transfer function of digital x-ray detectors. , 2011, Medical physics.

[71]  E. Eid,et al.  Design and characterization of ionizing radiation-tolerant CMOS APS image sensors up to 30 Mrd (Si) total dose , 2001 .

[72]  John A. Rowlands,et al.  Flat Panel Detectors for Digital Radiography , 2000 .

[73]  Robert D. Speller,et al.  The Dexela 2923 CMOS X-ray detector: A flat panel detector based on CMOS active pixel sensors for medical imaging applications , 2012 .