Performance Evaluation of National Standard Class Measurement System for Lightning Impulse Voltage
暂无分享,去创建一个
An impulse voltage measuring system of which performance is able to regard as the national standard class in Japan was developed in 1999. The same year, international comparison tests of the impulse measuring system were carried out among 23 countries. The performance of the impulse voltage measuring system in Japan was excellent.For this measuring system in Japan, some tests to evaluate various performances of the components were carried out and the overall uncertainty of the system was estimated after the international comparison tests.In this paper, the national standard class impulse voltage measuring system in Japan is described and its measuring uncertainty is discussed.
[1] Tatsuya Harada,et al. Development of National Standard Class Reference Divider for impulse voltage measurements , 1999 .
[2] Tatsuya Harada,et al. Development of Japan's National Standard Class 500 kV lightning impulse voltage divider , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).
[3] Masaru Ishii,et al. Construction and Performance Evaluation of Calibration System for Low Voltage Impulse , 2007 .