C-arm angle measurement with accelerometer for brachytherapy: an accuracy study

Purpose X-ray fluoroscopy guidance is frequently used in medical interventions. Image-guided interventional procedures that employ localization for registration require accurate information about the C-arm’s rotation angle that provides the data externally in real time. Optical, electromagnetic, and image-based pose tracking systems have limited convenience and accuracy. An alternative method to recover C-arm orientation was developed using an accelerometer as tilt sensor.Methods    The fluoroscopic C-arm’s orientation was estimated using a tri-axial acceleration sensor mounted on the X-ray detector as a tilt sensor. When the C-arm is stationary, the measured acceleration direction corresponds to the gravitational force direction. The accelerometer was calibrated with respect to the C-arm’s rotation along its two axes, using a high-accuracy optical tracker as a reference. The scaling and offset error of the sensor was compensated using polynomial fitting. The system was evaluated on a GE OEC 9800 C-arm. Results obtained by accelerometer, built-in sensor, and image-based tracking were compared, using optical tracking as ground truth data.Results The accelerometer-based orientation measurement error for primary angle rotation was $$-0.1\pm 0.0^{\circ }$$-0.1±0.0∘ and for secondary angle rotation it was $$0.1\pm 0.0^{\circ }$$0.1±0.0∘. The built-in sensor orientation measurement error for primary angle rotation was $$-0.1\pm 0.2^{\circ }$$-0.1±0.2∘, and for secondary angle rotation it was $$0.1\pm 0.2^{\circ }$$0.1±0.2∘. The image-based orientation measurement error for primary angle rotation was $$-0.1\pm 1.3^{\circ }$$-0.1±1.3∘, and for secondary angle rotation it was $$-1.3\pm 0.3^{\circ }$$-1.3±0.3∘.Conclusion The accelerometer provided better results than the built-in sensor and image-based tracking. The accelerometer sensor is small, inexpensive, covers the full rotation range of the C-arm, does not require line of sight, and can be easily installed to any mobile X-ray machine. Therefore, accelerometer tilt sensing is a very promising applicant for orientation angle tracking of C-arm fluoroscopes.

[1]  Gabor Fichtinger,et al.  REDMAPS: Reduced-Dimensionality Matching for Prostate Brachytherapy Seed Reconstruction , 2011, IEEE Transactions on Medical Imaging.

[2]  K. Cleary,et al.  Image-guided interventions: technology review and clinical applications. , 2010, Annual review of biomedical engineering.

[3]  Hans-Peter Meinzer,et al.  Pitfalls of electromagnetic tracking in clinical routine using multiple or adjacent sensors , 2013, The international journal of medical robotics + computer assisted surgery : MRCAS.

[4]  Gabor Fichtinger,et al.  C-arm rotation encoding with accelerometers , 2010, International Journal of Computer Assisted Radiology and Surgery.

[5]  K. Cleary,et al.  Image Guided Interventions. , 2020, Biomedizinische Technik. Biomedical engineering.

[6]  Gabor Fichtinger,et al.  CTREC: C-arm tracking and reconstruction using elliptic curves , 2008, 2008 IEEE Computer Society Conference on Computer Vision and Pattern Recognition Workshops.

[7]  Ameet K. Jain,et al.  FTRAC--a robust fluoroscope tracking fiducial. , 2005, Medical physics.

[8]  Gabor Fichtinger,et al.  Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis. , 2011, Medical physics.

[9]  A Gueziec,et al.  A C-arm fluoroscopy-guided progressive cut refinement strategy using a surgical robot. , 2000, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.