Development of a point of care lateral flow device for measuring human plasma fibrinogen.

Fibrinogen is a major cardiovascular disease risk factor and is an independent predictor of coronary heart disease and stroke. Normal reference levels are approximately 2 to 4 g/L. Elevated levels are associated with the occurrence of cardiovascular disease-related events. The risk of increased bleeding in major surgery is inversely correlated with fibrinogen concentrations for concentrations below the upper limit of the reference interval, i.e., <4 g/L. Determination of the clottable fibrinogen concentration in plasma is, thus, important for the investigation of coagulation disturbances in patients. A novel assay for monitoring plasma fibrinogen content has been developed on the basis of a simple, single use lateral flow microfluidic device. A 15 microL plasma sample is applied to and travels along the microstructured device where it comes into contact with a thrombin reagent. This induces conversion of the soluble fibrinogen to insoluble fibrin and brings about clot formation. Lateral sample flow is arrested as a result of clotting, and the distance along the device at which this occurs has been shown to be dependent on the fibrinogen concentration. The test range was from 1 to 7 g/L of fibrinogen in undiluted patient plasma, and a result could be obtained within 5 min.

[1]  Anthony J. Killard,et al.  Evaluation of a Range of Surface Modifications for the Enhancement of Lateral Flow Assays on Cyclic Polyolefin Micropillar Devices , 2009 .

[2]  M. Dudek,et al.  Plasma surface modification of cyclo-olefin polymers and its application to lateral flow bioassays. , 2009, Langmuir.

[3]  S. Skrtic,et al.  Prophylactic fibrinogen infusion reduces bleeding after coronary artery bypass surgery , 2009, Thrombosis and Haemostasis.

[4]  F. Baghaei,et al.  Plasma fibrinogen level, bleeding, and transfusion after on‐pump coronary artery bypass grafting surgery: a prospective observational study , 2008, Transfusion.

[5]  Bo Liedberg,et al.  Silane-dextran chemistry on lateral flow polymer chips for immunoassays. , 2008, Lab on a chip.

[6]  C. Klapperich,et al.  Thermoplastic microfluidic device for on-chip purification of nucleic acids for disposable diagnostics. , 2006, Analytical chemistry.

[7]  M. Woodward,et al.  Associations of Inflammatory and Hemostatic Variables With the Risk of Recurrent Stroke , 2005, Stroke.

[8]  T. G. Clark,et al.  Fibrinogen Concentration and Risk of Ischemic Stroke and Acute Coronary Events in 5113 Patients With Transient Ischemic Attack and Minor Ischemic Stroke , 2004, Stroke.

[9]  P. Sweetnam,et al.  Haemostatic/inflammatory markers predict 10-year risk of IHD at least as well as lipids: the Caerphilly collaborative studies. , 2004, European heart journal.

[10]  M. Woodward,et al.  Does sticky blood predict a sticky end? Associations of blood viscosity, haematocrit and fibrinogen with mortality in the West of Scotland , 2003, British journal of haematology.

[11]  G. Lowe,et al.  A Performance Evaluation of Commercial Fibrinogen Reference Preparations and Assays for Clauss and PT-derived Fibrinogen , 2002, Thrombosis and Haemostasis.

[12]  C. Négrier,et al.  Human plasma fibrinogen measurement derived from activated partial thromboplastin time clot formation , 2002, Blood coagulation & fibrinolysis : an international journal in haemostasis and thrombosis.

[13]  G D Lowe,et al.  Haematocrit, viscosity, erythrocyte sedimentation rate: meta-analyses of prospective studies of coronary heart disease. , 2000, European heart journal.

[14]  M. Frojmovic,et al.  Glycoprotein IIb-IIIa-liposomes bind fibrinogen but do not undergo fibrinogen-mediated aggregation. , 2000, Platelets.

[15]  P. Savage,et al.  The relationship of fibrinogen and factors VII and VIII to incident cardiovascular disease and death in the elderly: results from the cardiovascular health study. , 1999, Arteriosclerosis, thrombosis, and vascular biology.

[16]  F. Rosendaal,et al.  Increased Levels of Factor VIII and Fibrinogen in Patients with Venous Thrombosis Are not Caused by Acute Phase Reactions , 1999, Thrombosis and Haemostasis.

[17]  I. Mackie,et al.  Prothrombin time derived fibrinogen determination on Sysmex CA-6000. , 1998, Journal of clinical pathology.

[18]  M. Mosesson,et al.  Fibrinogen Structure and Fibrin Clot Assembly , 1998, Seminars in thrombosis and hemostasis.

[19]  Fowkes,et al.  Haemostatic factors and prediction of ischaemic heart disease and stroke in claudicants , 1998, British journal of haematology.

[20]  P C Elwood,et al.  Fibrinogen, viscosity and the 10-year incidence of ischaemic heart disease. , 1996, European heart journal.

[21]  I. Mackie,et al.  Inaccuracy of the 'derived' fibrinogen measurement. , 1994, Blood coagulation & fibrinolysis : an international journal in haemostasis and thrombosis.

[22]  P. Reitsma,et al.  Factor VII and Fibrinogen Levels as Risk Factors for Venous Thrombosis , 1994, Thrombosis and Haemostasis.

[23]  P C Elwood,et al.  Fibrinogen, Viscosity, and White Blood Cell Count Are Major Risk Factors for Ischemic Heart Disease: The Caerphilly and Speedwell Collaborative Heart Disease Studies , 1991, Circulation.

[24]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[25]  P. Gaffney,et al.  The sulphite precipitation method for fibrinogen measurement; its use on small samples in the presence of fibrinogen degradation products. , 1976, Clinica chimica acta; international journal of clinical chemistry.

[26]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[27]  M. Verstraete,et al.  A rapid enzymatic method for assay of fibrinogen fibrin polymerization time (FPT test). , 1963, Clinica chimica acta; international journal of clinical chemistry.

[28]  A. Clauss,et al.  Gerinnungsphysiologische Schnellmethode zur Bestimmung des Fibrinogens , 1957 .

[29]  P. White,et al.  A CLINICAL STUDY OF THE COAGULATION TIME OF BLOOD , 1913 .

[30]  P. Llamas,et al.  Diagnostic utility of comparing fibrinogen Clauss and prothrombin time derived method. , 2004, Thrombosis research.