Aortic vessel wall magnetic resonance imaging at 3.0 Tesla: A reproducibility study of respiratory navigator gated free‐breathing 3D black blood magnetic resonance imaging

The purpose of this study was to evaluate a free‐breathing three‐dimensional (3D) dual inversion‐recovery (DIR) segmented k‐space gradient‐echo (turbo field echo [TFE]) imaging sequence at 3T for the quantification of aortic vessel wall dimensions. The effect of respiratory motion suppression on image quality was tested. Furthermore, the reproducibility of the aortic vessel wall measurements was investigated. Seven healthy subjects underwent 3D DIR TFE imaging of the aortic vessel wall with and without respiratory navigator. Subsequently, this sequence with respiratory navigator was performed twice in 10 healthy subjects to test its reproducibility. The signal‐to‐noise (SNR), contrast‐to‐noise ratio (CNR), vessel wall sharpness, and vessel wall volume (VWV) were assessed. Data were compared using the paired t‐test, and the reproducibility of VWV measurements was evaluated using intraclass correlation coefficients (ICCs). SNR, CNR, and vessel wall sharpness were superior in scans performed with respiratory navigator compared to scans performed without. The ICCs concerning intraobserver, interobserver, and interscan reproducibility were excellent (0.99, 0.94, and 0.95, respectively). In conclusion, respiratory motion suppression substantially improves image quality of 3D DIR TFE imaging of the aortic vessel wall at 3T. Furthermore, this optimized technique with respiratory motion suppression enables assessment of aortic vessel wall dimensions with high reproducibility. Magn Reson Med 61:35–44, 2009. © 2008 Wiley‐Liss, Inc.

[1]  W. S. Monkhouse,et al.  GRAY'S ANATOMY , 1947 .

[2]  L. Solberg,et al.  Risk factors and atherosclerotic lesions. A review of autopsy studies. , 1983, Arteriosclerosis.

[3]  C. Zarins,et al.  Compensatory enlargement of human atherosclerotic coronary arteries. , 1987, The New England journal of medicine.

[4]  D Chien,et al.  Fast selective black blood MR imaging. , 1991, Radiology.

[5]  R W Parkey,et al.  Fast short-tau inversion-recovery MR imaging. , 1991, Radiology.

[6]  Richard L. Ehman,et al.  A monitoring, feedback, and triggering system for reproducible breath‐hold MR imaging , 1993, Magnetic resonance in medicine.

[7]  R. Pettigrew,et al.  Two-dimensional coronary MR angiography without breath holding. , 1996, Radiology.

[8]  M. McConnell,et al.  Prospective adaptive navigator correction for breath‐hold MR coronary angiography , 1997, Magnetic resonance in medicine.

[9]  H. Wen,et al.  The intrinsic signal-to-noise ratio in human cardiac imaging at 1.5, 3, and 4 T. , 1997, Journal of magnetic resonance.

[10]  M. McConnell,et al.  Comparison of respiratory suppression methods and navigator locations for MR coronary angiography. , 1997, AJR. American journal of roentgenology.

[11]  René M. Botnar,et al.  Navigator assessment of breath-hold duration: impact of supplemental oxygen and hyperventilation. , 1998, AJR. American journal of roentgenology.

[12]  René M. Botnar,et al.  Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA. , 1999, Circulation.

[13]  Zahi A Fayad,et al.  Acute coronary syndromes: biology , 1999, The Lancet.

[14]  René M. Botnar,et al.  Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography. , 1999, Journal of the American College of Cardiology.

[15]  V. Fuster,et al.  In vivo magnetic resonance evaluation of atherosclerotic plaques in the human thoracic aorta: a comparison with transesophageal echocardiography. , 2000, Circulation.

[16]  J. Rouleau,et al.  Vasopeptidase Inhibitors: A New Therapeutic Concept in Cardiovascular Disease? , 2001, Circulation.

[17]  L. Dougherty,et al.  Cardiac imaging at 4 Tesla , 2001, Magnetic resonance in medicine.

[18]  René M. Botnar,et al.  Scan reproducibility of magnetic resonance imaging assessment of aortic atherosclerosis burden. , 2001, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[19]  Russell V. Lenth,et al.  Some Practical Guidelines for Effective Sample Size Determination , 2001 .

[20]  René M. Botnar,et al.  3D coronary vessel wall imaging utilizing a local inversion technique with spiral image acquisition , 2001, Magnetic resonance in medicine.

[21]  V. Fuster,et al.  Effects of Lipid-Lowering by Simvastatin on Human Atherosclerotic Lesions: A Longitudinal Study by High-Resolution, Noninvasive Magnetic Resonance Imaging , 2001, Circulation.

[22]  René M. Botnar,et al.  “Soap‐Bubble” visualization and quantitative analysis of 3D coronary magnetic resonance angiograms , 2002, Magnetic resonance in medicine.

[23]  V. Fuster,et al.  Lipid Lowering by Simvastatin Induces Regression of Human Atherosclerotic Lesions: Two Years’ Follow-Up by High-Resolution Noninvasive Magnetic Resonance Imaging , 2002, Circulation.

[24]  René M. Botnar,et al.  Age and Sex Distribution of Subclinical Aortic Atherosclerosis: A Magnetic Resonance Imaging Examination of the Framingham Heart Study , 2002, Arteriosclerosis, thrombosis, and vascular biology.

[25]  René M. Botnar,et al.  Three-Dimensional Black-Blood Cardiac Magnetic Resonance Coronary Vessel Wall Imaging Detects Positive Arterial Remodeling in Patients With Nonsignificant Coronary Artery Disease , 2002, Circulation.

[26]  J. H. C. Reiber,et al.  Automatic segmentation and plaque characterization in atherosclerotic carotid artery MR images , 2004, Magnetic Resonance Materials in Physics, Biology and Medicine.

[27]  David A Bluemke,et al.  Using MRI to assess aortic wall thickness in the multiethnic study of atherosclerosis: distribution by race, sex, and age. , 2004, AJR. American journal of roentgenology.

[28]  Z. Fayad,et al.  In vivo magnetic resonance evaluation of associations between aortic atherosclerosis and both risk factors and coronary artery disease in patients referred for coronary angiography. , 2004, American heart journal.

[29]  Peter Boesiger,et al.  Cardiac SSFP imaging at 3 Tesla , 2004, Magnetic resonance in medicine.

[30]  V. Fuster,et al.  Effects of aggressive versus conventional lipid-lowering therapy by simvastatin on human atherosclerotic lesions: a prospective, randomized, double-blind trial with high-resolution magnetic resonance imaging. , 2005, Journal of the American College of Cardiology.

[31]  Z. Fayad,et al.  Effect of lipid-lowering therapy with atorvastatin on atherosclerotic aortic plaques detected by noninvasive magnetic resonance imaging. , 2005, Journal of the American College of Cardiology.

[32]  J H C Reiber,et al.  Optimizing the automatic segmentation of the left ventricle in magnetic resonance images. , 2005, Medical physics.

[33]  A. Carvalho,et al.  Thoracic aorta evaluation in patients with Takayasu's arteritis by transesophageal echocardiography. , 2006, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[34]  G. Adam,et al.  Multicontrast-weighted magnetic resonance imaging of atherosclerotic plaques at 3.0 and 1.5 Tesla: ex-vivo comparison with histopathologic correlation , 2006, European Radiology.

[35]  Boudewijn P F Lelieveldt,et al.  Automatic vessel wall contour detection and quantification of wall thickness in in‐vivo MR images of the human aorta , 2006, Journal of magnetic resonance imaging : JMRI.

[36]  Z. Fayad,et al.  A Possible Association Between Coronary Plaque Instability and Complex Plaques in Abdominal Aorta , 2006, Arteriosclerosis, thrombosis, and vascular biology.

[37]  René M. Botnar,et al.  Subclinical Coronary and Aortic Atherosclerosis Detected by Magnetic Resonance Imaging in Type 1 Diabetes With and Without Diabetic Nephropathy , 2006, Circulation.

[38]  Debiao Li,et al.  Diffusion-prepared segmented steady-state free precession: Application to 3D black-blood cardiovascular magnetic resonance of the thoracic aorta and carotid artery walls. , 2007, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[39]  Matthias Stuber,et al.  Assessment of the carotid artery by MRI at 3T: A study on reproducibility , 2007, Journal of magnetic resonance imaging : JMRI.

[40]  C. Weiller,et al.  Reliability of aortic MRI at 3 Tesla in patients with acute cryptogenic stroke , 2007, Journal of Neurology, Neurosurgery, and Psychiatry.

[41]  C. Weiller,et al.  Optimized 3D bright blood MRI of aortic plaque at 3 T. , 2008, Magnetic resonance imaging.