Cavitation occurrence around ultrasonic dental scalers.

Ultrasonic scalers are used in dentistry to remove calculus and other contaminants from teeth. One mechanism which may assist in the cleaning is cavitation generated in cooling water around the scaler. The vibratory motion of three designs of scaler tip in a water bath has been characterised by laser vibrometry, and compared with the spatial distribution of cavitation around the scaler tips observed using sonochemiluminescence from a luminol solution. The type of cavitation was confirmed by acoustic emission analysed by a 'Cavimeter' supplied by NPL. A node/antinode vibration pattern was observed, with the maximum displacement of each type of tip occurring at the free end. High levels of cavitation activity occurred in areas surrounding the vibration antinodes, although minimal levels were observed at the free end of the tip. There was also good correlation between vibration amplitude and sonochemiluminescence at other points along the scaler tip. 'Cavimeter' analysis correlated well with luminol observations, suggesting the presence of primarily transient cavitation.

[1]  S. C. Lea,et al.  Displacement amplitude of ultrasonic scaler inserts. , 2003, Journal of clinical periodontology.

[2]  T. Leighton The Acoustic Bubble , 1994 .

[3]  S. C. Lea,et al.  Assessing the vibrations of dental ultrasonic scalers , 2004 .

[4]  A. Heinecke,et al.  A systematic review of efficacy of machine-driven and manual subgingival debridement in the treatment of chronic periodontitis. , 2002, Journal of clinical periodontology.

[5]  B. P. Wilson,et al.  Mechanistic and Spatial Study of Ultrasonically Induced Luminol Chemiluminescence , 1999 .

[6]  W R Laird,et al.  Dental plaque removal by cavitational activity during ultrasonic scaling. , 1988, Journal of clinical periodontology.

[7]  M. Hodnett,et al.  A novel sensor for monitoring acoustic cavitation. Part I: Concept, theory, and prototype development , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[9]  Bajram Zeqiri,et al.  Acoustic emission spectra from 515 kHz cavitation in aqueous solutions containing surface-active solutes. , 2007, Journal of the American Chemical Society.

[10]  W. Teughels,et al.  Innovations in non-surgical periodontal therapy: Consensus Report of the Sixth European Workshop on Periodontology. , 2008, Journal of clinical periodontology.

[11]  S. C. Lea,et al.  Advances in power driven pocket/root instrumentation. , 2008, Journal of clinical periodontology.

[12]  Remo Guidieri Res , 1995, RES: Anthropology and Aesthetics.

[13]  Bajram Zeqiri,et al.  High-frequency acoustic emissions generated by a 20 kHz sonochemical horn processor detected using a novel broadband acoustic sensor: a preliminary study. , 2003, Ultrasonics sonochemistry.

[14]  W Lauterborn,et al.  High-speed observation of acoustic cavitation erosion in multibubble systems. , 2004, Ultrasonics sonochemistry.

[15]  Olgert Lindau,et al.  Bubble dynamics, shock waves and sonoluminescence , 1999, Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences.

[16]  S. C. Lea,et al.  Thermal imaging of ultrasonic scaler tips during tooth instrumentation. , 2004, Journal of clinical periodontology.

[17]  A. Walmsley,et al.  A Model System to Demonstrate the Role of Cavitational Activity in Ultrasonic Scaling , 1984, Journal of dental research.

[18]  Xingwang Fang,et al.  OH radical formation by ultrasound in aqueous solutions Part I: the chemistry underlying the terephthalate dosimeter , 1996 .

[19]  S. C. Lea,et al.  A study to determine whether cavitation occurs around dental ultrasonic scaling instruments. , 2005, Ultrasonics sonochemistry.

[20]  A. Henglein Chemical effects of continuous and pulsed ultrasound in aqueous solutions , 1995 .