Dynamic photometric imaging polarizer-sample-analyzer polarimeter: instrument for mapping birefringence and optical rotation

An imaging dynamic photopolarimeter in an optical configuration P(α)SA(n) (polarizer-sample-analyzer) having harmonically rotating polarizer (P) and analyzer (A), is presented for studies of inhomogeneous birefringent media. The method is capable of simple and precise measuring of birefringence and optical rotation across a two-dimensional field. Although the basic principle upon which the method operates has been proposed earlier, the focus here is on its extension, applicable to a whole field, and immediate measurement of three optical parameters, which have direct physical meaning. Earlier versions of the instrument either operate with a single beam or measure components of Jones or Mueller matrices. The operation of the given method is consistent with a general idea of dynamic photopolarimetry by discrete Fourier analysis and entails digital procession of intensity images, obtained at nine equispaced positions of the polarizer and the analyzer during synchronous rotation of them. A technique of data acquisition is described, and a detailed error analysis is provided. Theoretical considerations are supplemented with testing measurements of a quartz phase plate.

[1]  C M Wang,et al.  Rotating-polarizer polarimeter for accurate retardance measurement. , 1997, Applied optics.

[2]  A D Nurse Full-field automated photoelasticity by use of a three-wavelength approach to phase stepping. , 1997, Applied optics.

[3]  R. Azzam,et al.  Photopolarimetric measurement of the Mueller matrix by Fourier analysis of a single detected signal. , 1978, Optics letters.

[4]  J. L. Pezzaniti,et al.  Linear polarization uniformity measurements taken with an imaging polarimeter , 1995 .

[5]  Rasheed M. A. Azzam,et al.  A simple Fourier photopolarimeter with rotating polarizer and analyzer for measuring Jones and Mueller matrices , 1978 .

[6]  J. L. Pezzaniti,et al.  Mueller matrix imaging polarimetry , 1995 .

[7]  John A. Pearce,et al.  Thermal damage quantification from tissue birefringence image analysis , 1993, Electronic Imaging.

[8]  D. Su,et al.  Method for determining the fast axis and phase retardation of a wave plate , 1996 .

[9]  Toru Yoshizawa,et al.  Two-dimensional birefringence measurement using the phase shifting technique , 1994 .

[10]  Derivation of retardation phase in computer-aided photoelasticity by using carrier fringe phase shifting. , 1997, Applied optics.

[11]  J A Quiroga,et al.  Phase measuring algorithm for extraction of isochromatics of photoelastic fringe patterns. , 1997, Applied optics.

[12]  D. Goldstein,et al.  Mueller matrix dual-rotating retarder polarimeter. , 1992, Applied optics.

[13]  Russell A. Chipman,et al.  Error analysis of a Mueller matrix polarimeter , 1990 .

[14]  T. K. Varadan,et al.  Computerized image processing for whole-field determination of isoclinics and isochromatics , 1992 .

[15]  Russell A. Chipman,et al.  Imaging polarimeters for optical metrology , 1990, Other Conferences.

[16]  Eann A. Patterson,et al.  Towards full field automated photoelastic analysis of complex components , 1991 .

[17]  M. V. van Gemert,et al.  Two-dimensional birefringence imaging in biological tissue using polarization-sensitive optical coherence tomography , 1997, European Conference on Biomedical Optics.