Using external and internal locking plates in a two-stage protocol for treatment of segmental tibial fractures.

BACKGROUND The tibial segmental fractures usually follow high-energy trauma and are often associated with many complications. We designed a two-stage protocol for these complex injuries. The aim of this study was to assess the outcome of tibial segmental fractures treated according to this protocol. METHODS A prospective series of 25 consecutive segmental tibial fractures were treated using a two-stage procedure. In the first stage, a low-profile locking plate was applied as an external fixator to temporarily immobilize the fractures after anatomic reduction had been achieved followed by soft-tissue reconstruction. The second stage involved definitive internal fixation with a locking plate using a minimally invasive percutaneous plate osteosynthesis technique. The median follow-up was 32 months (range, 20-44 months). RESULTS All fractures achieved union. The median time for the proximal fracture union was 23 weeks (range, 12-30 weeks) and that for distal fracture union was 27 weeks (range, 12-46 weeks; p = 0.08). Functional results were excellent in 21 patients and good in 4 patients. There were three cases of delayed union of distal fracture. Valgus malunion >5 degrees occurred in two patients, and length discrepancy >1 cm was observed in two patients. Pin tract infection occurred in three patients. CONCLUSIONS Use of the two-stage procedure for treatment of segmental tibial fractures is recommended. Surgeons can achieve good reduction with stable temporary fixation, soft-tissue reconstruction, ease of subsequent definitive fixation, and high union rates. Our patients obtained excellent knee and ankle joint motion, good functional outcomes, and a comfortable clinical course.

[1]  Y. Tu,et al.  Staged external and internal less-invasive stabilisation system plating for open proximal tibial fractures. , 2010, Injury.

[2]  I. Azboy,et al.  Acute treatment of segmental tibial fractures with the Ilizarov method. , 2009, Injury.

[3]  P. Kloen Supercutaneous plating: use of a locking compression plate as an external fixator. , 2009, Journal of orthopaedic trauma.

[4]  P. Rommens,et al.  Operative treatment of tibial shaft fractures: a comparison of different methods of primary stabilisation , 2008, Archives of Orthopaedic and Trauma Surgery.

[5]  K. Koval,et al.  Staged Management of High-Energy Proximal Tibia Fractures (OTA Types 41): The Results of a Prospective, Standardized Protocol , 2005, Journal of orthopaedic trauma.

[6]  M. Zlowodzki,et al.  Less Invasive Stabilization System (LISS) for fractures of the proximal tibia: indications, surgical technique and preliminary results of the UMC Clinical Trial. , 2003, Injury.

[7]  P. Giannoudis,et al.  Maintaining reduction during unreamed nailing of a segmental tibial fracture: the use of a Farabeuf clamp. , 2003, Injury.

[8]  R. Marti,et al.  External fixation with standard AO-plates: technique, indications, and results in 31 cases. , 2003, Journal of orthopaedic trauma.

[9]  M. İnan,et al.  [Treatment of type II and III open tibial fractures with Ilizarov external fixation]. , 2002, Acta orthopaedica et traumatologica turcica.

[10]  R. Frigg,et al.  Locking Compression Plate (LCP). An osteosynthesis plate based on the Dynamic Compression Plate and the Point Contact Fixator (PC-Fix). , 2001, Injury.

[11]  S M Perren,et al.  Evolution and rationale of locked internal fixator technology. Introductory remarks. , 2001, Injury.

[12]  W. Lo,et al.  Segmental tibial fractures treated with interlocking nails. A retrospective study of 33 cases. , 1997, Acta orthopaedica Scandinavica.

[13]  G. Dendrinos,et al.  Treatment of high-energy tibial plateau fractures by the Ilizarov circular fixator. , 1996, The Journal of bone and joint surgery. British volume.

[14]  A. Mølster,et al.  Open Tibial Fractures Treated With the Ex-fi-re External Fixation System , 1996, Clinical orthopaedics and related research.

[15]  C. Shih,et al.  Segmental Tibial Shaft Fractures Treated with Interlocking Nailing , 1993, Journal of orthopaedic trauma.

[16]  A. Sarmiento,et al.  Tibial shaft fractures treated with functional braces. Experience with 780 fractures. , 1989, The Journal of bone and joint surgery. British volume.

[17]  R. Gustilo,et al.  Infection after intramedullary nailing of severe open tibial fractures initially treated with external fixation. , 1989, The Journal of bone and joint surgery. American volume.

[18]  P. Broos,et al.  Intrinsic problems with the external fixation device of Hoffmann-Vidal-Adrey: a critical evaluation of 117 patients with complex tibial shaft fractures. , 1989, The Journal of trauma.

[19]  P. Anderson,et al.  Risk of infection after open fracture of the arm or leg. , 1988, Archives of surgery.

[20]  A Grosse,et al.  Closed locked intramedullary nailing. Its application to comminuted fractures of the femur. , 1985, The Journal of bone and joint surgery. American volume.

[21]  D. N. Williams,et al.  Problems in the management of type III (severe) open fractures: a new classification of type III open fractures. , 1984, The Journal of trauma.

[22]  K. D. Kristensen Tibial shaft fractures. The frequency of local complications in tibial shaft fractures treated by internal compression osteosynthesis. , 1979, Acta orthopaedica Scandinavica.

[23]  K. Larsson,et al.  Plate fixation versus conservative treatment of tibial shaft fractures. A randomized trial. , 1979, The Journal of bone and joint surgery. American volume.

[24]  O. Langård,et al.  Segmental tibial shaft fractures. , 1976, Acta orthopaedica Scandinavica.