Grid Voltage Synchronization for Distributed Generation Systems Under Grid Fault Conditions

The actual grid code requirements for the grid connection of distributed generation systems, mainly wind and photovoltaic (PV) systems, are becoming very demanding. The transmission system operators (TSOs) are especially concerned about the low-voltage-ride-through requirements. Solutions based on the installation of STATCOMs and dynamic voltage regulators (DVRs), as well as on advanced control functionalities for the existing power converters of distributed generation plants, have contributed to enhance their response under faulty and distorted scenarios and, hence, to fulfill these requirements. In order to achieve satisfactory results with such systems, it is necessary to count on accurate and fast grid voltage synchronization algorithms, which are able to work under unbalanced and distorted conditions. This paper analyzes the synchronization capability of three advanced synchronization systems: the decoupled double synchronous reference frame phase-locked loop (PLL), the dual second order generalized integrator PLL, and the three-phase enhanced PLL, designed to work under such conditions. Although other systems based on frequency-locked loops have also been developed, PLLs have been chosen due to their link with dq0 controllers. In the following, the different algorithms will be presented and discretized, and their performance will be tested in an experimental setup controlled in order to evaluate their accuracy and implementation features.

[1]  Katsuhiko Ogata,et al.  Discrete-time control systems , 1987 .

[2]  V. Blasko,et al.  Operation of a phase locked loop system under distorted utility conditions , 1996, Proceedings of Applied Power Electronics Conference. APEC '96.

[3]  Jon Are Suul,et al.  Low Voltage Ride Through of Wind Farms With Cage Generators: STATCOM Versus SVC , 2008, IEEE Transactions on Power Electronics.

[4]  H. Awad,et al.  Mitigation of unbalanced voltage dips using static series compensator , 2004, IEEE Transactions on Power Electronics.

[5]  P. Rodriguez,et al.  Low voltage ride through strategies for SCIG wind turbines in distributed power generation systems , 2008, 2008 IEEE Power Electronics Specialists Conference.

[6]  Leopoldo García Franquelo,et al.  A Flexible Selective Harmonic Mitigation Technique to Meet Grid Codes in Three-Level PWM Converters , 2007, IEEE Transactions on Industrial Electronics.

[7]  Marco Liserre,et al.  New Positive-sequence Voltage Detector for Grid Synchronization of Power Converters under Faulty Grid Conditions , 2006 .

[8]  D. Boroyevich,et al.  Double Synchronous Reference Frame PLL for Power Converters Control , 2005, 2005 IEEE 36th Power Electronics Specialists Conference.

[9]  S.M. Silva,et al.  PLL structures for utility connected systems , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[10]  M. Bongiorno,et al.  An Advanced Cascade Controller for Series-Connected VSC for Voltage Dip Mitigation , 2005, IEEE Transactions on Industry Applications.

[11]  Math Bollen,et al.  Characteristic of voltage dips (sags) in power systems , 1998, 8th International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.98EX227).

[12]  Luis Marroyo,et al.  Individual Voltage Balancing Strategy for PWM Cascaded H-Bridge Converter-Based STATCOM , 2008, IEEE Transactions on Industrial Electronics.

[13]  Roberto Cárdenas,et al.  Sensorless Control of Doubly-Fed Induction Generators Using a Rotor-Current-Based MRAS Observer , 2008, IEEE Transactions on Industrial Electronics.

[14]  Math Bollen,et al.  Characteristic of voltage dips (sags) in power systems , 2000 .

[15]  António J. Marques Cardoso,et al.  A New Model-Based Technique for the Diagnosis of Rotor Faults in RFOC Induction Motor Drives , 2008, IEEE Transactions on Industrial Electronics.

[16]  Li Ran,et al.  Control of a doubly fed induction generator in a wind turbine during grid fault ride-through , 2006, IEEE Transactions on Energy Conversion.

[17]  J. Morren,et al.  Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip , 2005, IEEE Transactions on Energy Conversion.

[18]  Frede Blaabjerg,et al.  Flexible Active Power Control of Distributed Power Generation Systems During Grid Faults , 2007, IEEE Transactions on Industrial Electronics.

[19]  Scott D. Sudhoff,et al.  Analysis of Electric Machinery and Drive Systems , 1995 .

[20]  K. Shanti Swarup,et al.  High-Speed Fault Classification in Power Lines: Theory and FPGA-Based Implementation , 2009, IEEE Transactions on Industrial Electronics.

[21]  M. B. Zarrop,et al.  Book Review: Computer Controlled Systems: theory and design (3rd Ed.) , 1998 .

[22]  D. Boroyevich,et al.  Decoupled Double Synchronous Reference Frame PLL for Power Converters Control , 2007, IEEE Transactions on Power Electronics.

[23]  Marian P. Kazmierkowski,et al.  Control of Three-Level PWM Converter Applied to Variable-Speed-Type Turbines , 2009, IEEE Transactions on Industrial Electronics.

[24]  I. Erlich,et al.  Strategies for Wind Power Trading in Competitive Electricity Markets , 2008, IEEE Transactions on Energy Conversion.

[25]  Poul Ejnar Sørensen,et al.  Mapping of grid faults and grid codes , 2007 .

[26]  J. Svensson,et al.  Dynamic Performance Comparison of Synchronous Condenser and SVC , 2008, IEEE Transactions on Power Delivery.

[27]  Karl Johan Åström,et al.  Computer-Controlled Systems: Theory and Design , 1984 .

[28]  Stavros A. Papathanassiou,et al.  A review of grid code technical requirements for wind farms , 2009 .

[29]  Se-Kyo Chung,et al.  A phase tracking system for three phase utility interface inverters , 2000 .

[30]  M. R. Iravani,et al.  A Nonlinear Adaptive Filter for Online Signal Analysis in Power Systems: Applications , 2002, IEEE Power Engineering Review.

[31]  Liuchen Chang,et al.  An Advanced SVPWM-Based Predictive Current Controller for Three-Phase Inverters in Distributed Generation Systems , 2008, IEEE Transactions on Industrial Electronics.

[32]  M. Liserre,et al.  Synchronization methods for three phase distributed power generation systems - An overview and evaluation , 2005, 2005 IEEE 36th Power Electronics Specialists Conference.

[33]  Jian Li Discrete-Time Signals and Systems , 1999 .

[34]  F. Blaabjerg,et al.  Doubly-Fed Induction Generator Control Under Voltage Sags , 2008, 2008 IEEE Energy 2030 Conference.

[35]  Jinjun Liu,et al.  Strategies and Operating Point Optimization of STATCOM Control for Voltage Unbalance Mitigation in Three-Phase Three-Wire Systems , 2007, IEEE Transactions on Power Delivery.

[36]  W. L. Melvin,et al.  Continuous-time to discrete-time conversion via a novel parametrized s-to-z-plane mapping , 1997 .

[37]  Leonardo A. B. Tôrres,et al.  Comparison of Three Single-Phase PLL Algorithms for UPS Applications , 2008, IEEE Transactions on Industrial Electronics.

[38]  H. Stemmler,et al.  Stationary frame generalized integrators for current control of active power filters with zero steady state error for current harmonics of concern under unbalanced and distorted operation conditions , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[39]  Sergio Busquets-Monge,et al.  Control Strategies Based on Symmetrical Components for Grid-Connected Converters Under Voltage Dips , 2009, IEEE Transactions on Industrial Electronics.

[40]  M.R. Iravani,et al.  A method for synchronization of power electronic converters in polluted and variable-frequency environments , 2004, IEEE Transactions on Power Systems.

[41]  Frede Blaabjerg,et al.  Overview of Control and Grid Synchronization for Distributed Power Generation Systems , 2006, IEEE Transactions on Industrial Electronics.

[42]  J. Svensson,et al.  Voltage tolerance testing of three-phase voltage source converters , 2005, IEEE Transactions on Power Delivery.

[43]  B Tomislav Sekara,et al.  Application of the α-approximation for discretization of analogue systems , 2005 .

[44]  S. Arnalte,et al.  Direct Power Control Applied to Doubly Fed Induction Generator Under Unbalanced Grid Voltage Conditions , 2008, IEEE Transactions on Power Electronics.

[45]  B. Anderson,et al.  Digital control of dynamic systems , 1981, IEEE Transactions on Acoustics, Speech, and Signal Processing.

[46]  A. Sannino,et al.  Improving Voltage Disturbance Rejection for Variable-Speed Wind Turbines , 2002, IEEE Power Engineering Review.

[47]  M.R. Iravani,et al.  Measurement of harmonics/inter-harmonics of time-varying frequencies , 2005, IEEE Transactions on Power Delivery.

[48]  Nasir Ahmed,et al.  Discrete Time Signals and Systems , 1983 .

[49]  Amit K. Jain,et al.  Wound Rotor Induction Generator With Sensorless Control and Integrated Active Filter for Feeding Nonlinear Loads in a Stand-Alone Grid , 2008, IEEE Transactions on Industrial Electronics.