Management of Anesthesia Equipment Failure: A Simulation-Based Resident Skill Assessment

BACKGROUND: Intraoperative anesthesia equipment failures are a cause of anesthetic morbidity. Our purpose in this study was 1) to design a set of simulated scenarios that measure skill in managing intraoperative equipment-related errors and 2) to evaluate the reliability and validity of the measures from this multiple scenario assessment. METHODS: Eight intraoperative scenarios were created to test anesthesia residents’ skills in managing a number of equipment-related failures. Fifty-six resident physicians, divided into four groups based on their training year (Resident 1-Resident 4), participated in the individual simulation-based assessment of equipment-related failures. The score for each scenario was generated by a checklist of key actions relevant to each scenario and time to complete these actions. RESULTS: The residents’ scores, on average, improved with increased level of training. The more senior residents (R3 and R4) performed better than more junior residents (R1 and R2). Despite similar training background, there was a wide range of skill among the residents within each training year. The summary score on the eight scenario assessments, measured by either the key actions or the time required to manage the events, yielded a reliable estimate of a resident’s skill in managing these simulated equipment failures. DISCUSSION: Anesthesia residents’ performances could be reliably evaluated using a set of simulated intraoperative equipment problems. This multiple scenario assessment was an effective method to evaluate individual performance. The summary results, by training year, could be used to determine how successful current instructional methods are for acquiring skill.

[1]  J. Devitt,et al.  Inadequate preanesthesia equipment checks in a simulator , 2000, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[2]  Xiaohong Gao,et al.  Variability of Estimated Variance Components and Related Statistics in a Performance Assessment , 2001 .

[3]  A. Usher,et al.  Critical incident with Narkomed 6000 Anesthesia System. , 2003, Anesthesiology.

[4]  Robert A. Caplan,et al.  Adverse Anesthetic Outcomes Arising from Gas Delivery Equipment: A Closed Claims Analysis , 1997, Anesthesiology.

[5]  T. Vemmer,et al.  Isoflurane damage to a Draeger Primus anaesthetic machine , 2004, Anaesthesia.

[6]  Eric R. Larson,et al.  A Prospective Study on Anesthesia Machine Fault Identification , 2007, Anesthesia and analgesia.

[7]  R. Reznick,et al.  The use of global ratings in OSCE station scores , 1996, Advances in health sciences education : theory and practice.

[8]  M. Olympio,et al.  Instructional Review Improves Performance of Anesthesia Apparatus Checkout Procedures , 1996, Anesthesia and analgesia.

[9]  R S Newbower,et al.  An Analysis of Major Errors and Equipment Failures in Anesthesia Management: Considerations for Prevention and Detection , 1984, Anesthesiology.

[10]  D. Gaba,et al.  Assessment of Clinical Performance during Simulated Crises Using Both Technical and Behavioral Ratings , 1998, Anesthesiology.

[11]  D. Klass,et al.  Setting examination-level standards for a performance-based assessment of physicians' clinical skills. , 1998, Academic medicine : journal of the Association of American Medical Colleges.

[12]  J. Hendrickx,et al.  Severe ADU desflurane vaporizing unit malfunction. , 2003, Anesthesiology.

[13]  W J Russell,et al.  Equipment Failure: An Analysis of 2000 Incident Reports , 1993 .

[14]  John R Boulet,et al.  Performance of Residents and Anesthesiologists in a Simulation-based Skill Assessment , 2007, Anesthesiology.

[15]  John R. Boulet Generalizability Theory: Basics , 2005 .

[16]  R. James,et al.  1000 anaesthetic incidents: experience to date , 2003, Anaesthesia.

[17]  Catalin S. Ezaru Preinduction check-up of the anesthesia machine. , 2006, Anesthesia and analgesia.

[18]  John R Boulet,et al.  A Simulation-Based Acute Skills Performance Assessment for Anesthesia Training , 2005, Anesthesia and analgesia.

[19]  J. P. Abenstein,et al.  Ventilator alarm failure due to modification of the scavenging system. , 2000, Anesthesiology.

[20]  A. J. Ferguson,et al.  Deliberate self‐poisoning with dapsone , 1997, Anaesthesia.

[21]  S. Fasting,et al.  Equipment problems during anaesthesia--are they a quality problem? , 2002, British journal of anaesthesia.

[22]  Robert L. Brennan,et al.  Generalizability of Performance Assessments , 2005 .