An MRI-Compatible Robotic System With Hybrid Tracking for MRI-Guided Prostate Intervention

This paper reports the development, evaluation, and first clinical trials of the access to the prostate tissue (APT) II system-a scanner independent system for magnetic resonance imaging (MRI)-guided transrectal prostate interventions. The system utilizes novel manipulator mechanics employing a steerable needle channel and a novel six degree-of-freedom hybrid tracking method, comprising passive fiducial tracking for initial registration and subsequent incremental motion measurements. Targeting accuracy of the system in prostate phantom experiments and two clinical human-subject procedures is shown to compare favorably with existing systems using passive and active tracking methods. The portable design of the APT II system, using only standard MRI image sequences and minimal custom scanner interfacing, allows the system to be easily used on different MRI scanners.

[1]  Zion Tsz Ho Tse,et al.  The case for MR‐compatible robotics: a review of the state of the art , 2008, The international journal of medical robotics + computer assisted surgery : MRCAS.

[2]  S. Dubowsky,et al.  MRI Compatible Device for Robotic Assisted Interventions to Prostate Cancer , 2009 .

[3]  S. Zangos,et al.  MR-guided transgluteal biopsies with an open low-field system in patients with clinically suspected prostate cancer: technique and preliminary results , 2004, European Radiology.

[4]  Gabor Fichtinger,et al.  Simultaneous integrated boost of biopsy proven, MRI defined dominant intra-prostatic lesions to 95 Gray with IMRT: early results of a phase I NCI study , 2007, Radiation oncology.

[5]  Alexandru Patriciu,et al.  “MRI Stealth” robot for prostate interventions , 2007, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[6]  M. Terris,et al.  Comparison of mid-lobe versus lateral systematic sextant biopsies in the detection of prostate cancer. , 1997, Urologia internationalis.

[7]  C. N. Coleman,et al.  Transrectal prostate biopsy and fiducial marker placement in a standard 1.5T magnetic resonance imaging scanner. , 2006, The Journal of urology.

[8]  K. Wallner,et al.  Performance of transperineal template-guided mapping biopsy in detecting prostate cancer in the initial and repeat biopsy setting , 2009, Prostate Cancer and Prostatic Diseases.

[9]  William Wells,et al.  Detection of prostate cancer by integration of line-scan diffusion, T2-mapping and T2-weighted magnetic resonance imaging; a multichannel statistical classifier. , 2003, Medical physics.

[10]  T. Stamey,et al.  PATTERNS OF PROGRESSION IN PROSTATE CANCER , 1986, The Lancet.

[11]  Andras Lasso,et al.  Accuracy validation for MRI-guided robotic prostate biopsy , 2010, Medical Imaging.

[12]  E Atalar,et al.  Endourethral MRI , 2001, Magnetic resonance in medicine.

[13]  L. Holmberg,et al.  The sextant protocol for ultrasound-guided core biopsies of the prostate underestimates the presence of cancer. , 1997, Urology.

[14]  R Kikinis,et al.  Robot-assisted needle placement in open MRI: System architecture, integration and validation , 2007, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[15]  J. A. Derbyshire,et al.  System for MR image-guided prostate interventions: canine study. , 2003, Radiology.

[16]  Saroja Adusumilli,et al.  Magnetic resonance imaging of prostate cancer. , 2002, Seminars in urologic oncology.

[17]  Thomas J Vogl,et al.  Prostate cancer: MR imaging-guided galvanotherapy--technical development and first clinical results. , 2007, Radiology.

[18]  Peter H Gann,et al.  Risk factors for prostate cancer detection after a negative biopsy: a novel multivariable longitudinal approach. , 2010, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[19]  Aaron Fenster,et al.  Quantification of Prostate Deformation due to Needle Insertion during TRUS-guided Biopsy , 2010, MICCAI.

[20]  D. Beyersdorff,et al.  MR imaging-guided prostate biopsy with a closed MR unit at 1.5 T: initial results. , 2005, Radiology.

[21]  J Kurhanewicz,et al.  Sextant localization of prostate cancer: comparison of sextant biopsy, magnetic resonance imaging and magnetic resonance spectroscopic imaging with step section histology. , 2000, The Journal of urology.

[22]  Gabor Fichtinger,et al.  A MRI Compatible Device for MRI Guided Transrectal Prostate Biopsy , 2002 .

[23]  Ian Young,et al.  The Feasibility of MR-Image Guided Prostate Biopsy Using Piezoceramic Motors Inside or Near to the Magnet Isocentre , 2006, MICCAI.

[24]  Katarzyna J Macura,et al.  MR-guided biopsy of the prostate: an overview of techniques and a systematic review. , 2008, European urology.

[25]  Jean-Sébastien Plante,et al.  The experimental study of a precision parallel manipulator with binary actuation: With application to MRI cancer treatment , 2008, 2008 IEEE International Conference on Robotics and Automation.

[26]  S. Souza,et al.  Real‐time position monitoring of invasive devices using magnetic resonance , 1993, Magnetic resonance in medicine.

[27]  Gene H. Golub,et al.  Matrix computations (3rd ed.) , 1996 .

[28]  Nobuhiko Hata,et al.  Magnetic Resonance-guided Prostate Interventions , 2005, Topics in magnetic resonance imaging : TMRI.

[29]  John B. Bak,et al.  Characterization of prostate cancer missed by sextant biopsy. , 2003, Clinical prostate cancer.

[30]  Axel Krieger,et al.  An Interventional Magnetic Resonance Imaging Technique for the Molecular Characterization of Intraprostatic Dynamic Contrast Enhancement , 2005, Molecular imaging.

[31]  A. D'Amico,et al.  Transperineal magnetic resonance image guided prostate biopsy. , 2000, The Journal of urology.

[32]  Thomas J. Vogl,et al.  MR-compatible assistance system for punction in a high-field system: device and feasibility of transgluteal biopsies of the prostate gland , 2007, European Radiology.

[33]  J C Presti,et al.  Prostate cancer: assessment of risk using digital rectal examination, tumor grade, prostate-specific antigen, and systematic biopsy. , 2000, Radiologic clinics of North America.

[34]  Gabor Fichtinger,et al.  A preliminary analysis and model of prostate injection distributions , 2006, The Prostate.

[35]  R L Somorjai,et al.  Magnetic resonance spectroscopy of the malignant prostate gland after radiotherapy: a histopathologic study of diagnostic validity. , 2001, International journal of radiation oncology, biology, physics.

[36]  R M Henkelman,et al.  Prostate cancer: MR imaging and thermometry during microwave thermal ablation-initial experience. , 2000, Radiology.

[37]  B. Kiefer,et al.  Prostate biopsy in the supine position in a standard 1.5-T scanner under real time MR-imaging control using a MR-compatible endorectal biopsy device , 2006, European Radiology.

[38]  Jan J W Lagendijk,et al.  MRI-guided robotic system for transperineal prostate interventions: proof of principle , 2010, Physics in medicine and biology.

[39]  Gabor Fichtinger,et al.  A hybrid method for 6-DOF tracking of MRI-compatible robotic interventional devices , 2006, Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006..

[40]  J. Barentsz,et al.  Title : MR-compatible transrectal prostate biopsy robot : a feasibility study , 2009 .

[41]  H. Hricak,et al.  Imaging of prostate cancer. , 2007, Radiologic clinics of North America.

[42]  Nobuhiko Hata,et al.  MR Compatible Surgical Assist Robot: System Integration and Preliminary Feasibility Study , 2000, MICCAI.

[43]  M. Barry,et al.  Detection of prostate cancer via biopsy in the Medicare-SEER population during the PSA era. , 2007, Journal of the National Cancer Institute.

[44]  U. G. Dailey Cancer,Facts and Figures about. , 2022, Journal of the National Medical Association.

[45]  M. Bronskill,et al.  Analysis of changes in MR properties of tissues after heat treatment , 1999, Magnetic resonance in medicine.

[46]  Bob Djavan,et al.  Biopsy standards for detection of prostate cancer , 2007, World Journal of Urology.

[47]  W. Kaiser,et al.  Robotic system for biopsy and therapy of breast lesions in a high-field whole-body magnetic resonance tomography unit. , 2000, Investigative radiology.

[48]  W. Kaiser,et al.  ROBITOM- ROBOT FOR BIOPSY AND THERAPY OF THE MAMMA , 2002 .

[49]  Martha K. Terris Strategies for repeat prostate biopsies , 2009 .

[50]  C. N. Coleman,et al.  System for prostate brachytherapy and biopsy in a standard 1.5 T MRI scanner , 2004, Magnetic resonance in medicine.

[51]  Gleason Df Classification of prostatic carcinomas. , 1966 .

[52]  A.A. Goldenberg,et al.  Robotic System for Closed-Bore MRI-Guided Prostatic Interventions , 2008, IEEE/ASME Transactions on Mechatronics.

[53]  F. Carpi,et al.  Biomedical applications of electroactive polymer actuators , 2009 .

[54]  William J Catalona,et al.  Serial biopsy results in prostate cancer screening study. , 2002, The Journal of urology.

[55]  Gabor Fichtinger,et al.  Development of a pneumatic robot for MRI-guided transperineal prostate biopsy and brachytherapy: New approaches , 2010, 2010 IEEE International Conference on Robotics and Automation.

[56]  Gene H. Golub,et al.  Matrix computations , 1983 .

[57]  Carl-Fredrik Westin,et al.  Processing and visualization for diffusion tensor MRI , 2002, Medical Image Anal..

[58]  W. Fair,et al.  Incidence and clinical significance of false-negative sextant prostate biopsies. , 1998, The Journal of urology.

[59]  G.S. Fischer,et al.  MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement , 2008, IEEE/ASME Transactions on Mechatronics.

[60]  Hessel Wijkstra,et al.  Transrectal ultrasound imaging and prostate cancer. , 2003, Archivio italiano di urologia, andrologia : organo ufficiale [di] Societa italiana di ecografia urologica e nefrologica.

[61]  Jurgen J Fütterer,et al.  Imaging modalities for prostate cancer , 2009, Expert review of anticancer therapy.

[62]  A S Whittemore,et al.  Localized prostate cancer. Relationship of tumor volume to clinical significance for treatment of prostate cancer , 1993, Cancer.

[63]  Gabor Fichtinger,et al.  Design of a novel MRI compatible manipulator for image guided prostate interventions , 2005, IEEE Transactions on Biomedical Engineering.

[64]  J A Rowlands,et al.  Imaging of 1.0-mm-diameter radiopaque markers with megavoltage X-rays: an improved online imaging system. , 2002, International journal of radiation oncology, biology, physics.