Quantitative three-dimensional confocal imaging of the cornea in situ and in vivo: system design and calibration.

A new depth encoding system (DES) is presented, which makes it possible to calculate, display, and record the z-axis position continuously during in vivo imaging using tandem scanning confocal microscopy (TSCM). In order to verify the accuracy of the DES for calculating the position of the focal plane in the cornea both in vitro and in vivo, we compared TSCM measurements of corneal thickness to measurements made using an ultrasonic pachymeter (UP, a standard clinical instrument) in both enucleated rabbit, cat, and human eyes (n = 15), and in both human patients (n = 7). Very close agreement was found between the UP and TSCM measurements in enucleated eyes; the mean percent difference was 0.50 +/- 2.58% (mean +/- SD, not significant). A significant correlation (R = 0.995, n = 15, p < 0.01) was found between UP and TSCM measurements. These results verify that the theoretical equation for calculating focal depth provided by the TSCM manufacturer is accurate for corneal imaging. Similarly, close agreement was found between the in vivo UP and TSCM measurements; the mean percent differences was 1.67 +/- 1.38% (not significant), confirming that z-axis drift can be minimized with proper applanation of the objective. These results confirm the accuracy of the DES for imaging of the cornea both ex vivo and in vivo. This system should be of great utility for applications where quantitation of the three-dimensional location of cellular structures is needed.

[1]  Alan Boyde,et al.  The tandem scanning reflected light microscope , 1968 .

[2]  H. D. Cavanagh,et al.  In vivo, real-time confocal imaging. , 1991, Journal of electron microscopy technique.

[3]  W M Petroll,et al.  Inhibition of Corneal Fibrosis by Topical Application of Blocking Antibodies to TGFβ in the Rabbit , 1997, Cornea.

[4]  Applications of Tandem Scanning Reflected Light Microscopy and Three‐Dimensional Imaging a , 1986, Annals of the New York Academy of Sciences.

[5]  W M Petroll,et al.  Clinical and diagnostic use of in vivo confocal microscopy in patients with corneal disease. , 1993, Ophthalmology.

[6]  W M Petroll,et al.  In vivo confocal microscopy in clinical dental research: an initial appraisal. , 1992, Journal of dentistry.

[7]  H. D. Cavanagh,et al.  Tandem scanning confocal microscopy (TSCM) of normal and ischemic living kidneys. , 1991, The American journal of anatomy.

[8]  W M Petroll,et al.  Digital image acquisition in in vivo confocal microscopy , 1992, Journal of microscopy.

[9]  W M Petroll,et al.  In vivo confocal imaging: general principles and applications. , 1994, Scanning.

[10]  W M Petroll,et al.  Three‐dimensional imaging of corneal cells using in vivo confocal microscopy , 1993, Journal of microscopy.

[11]  D. Maurice,et al.  The metabolic basis to the fluid pump in the cornea , 1972, The Journal of physiology.

[12]  A Boyde,et al.  In Vivo Microscopy Using the Tandem Scanning Microscope a , 1986, Annals of the New York Academy of Sciences.

[13]  W M Petroll,et al.  Measurement of Surgically Induced Corneal Deformations Using Three-Dimensional Confocal Microscopy , 1996, Cornea.